Desa VFRMV24NB, VFRMV24PB, VFRMV18NB Connecting to GAS Supply, Installation Items Needed

Page 13

Installation

Continued

CAUTION: Do not pick up heater assembly by logs. This could damage unit. Only handle assembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly.

Installation Items Needed

• control cover kit (provided with heater)

• approved flexible gas hose and fittings (pro- vided with heater) (if allowed by local codes)

• sealant (resistant to propane/LP gas, not provided)

Note: Install optional HRC100 and HRC200 Receiver and Hand-Held Remote Control Kit (see Accessories, page 26) before installing gas log heater. See installation instructions included with the kit.

1.Apply pipe joint sealant lightly to male threads of gas fitting (not provided). Connect approved flexible gas hose to inlet side of gas control (see Figure 12).

2.Position heater assembly in fireplace.

3.Connect to gas supply. See Connecting To Gas Supply.

Gas Control Valve

Flexible Gas Hose (if allowed by local codes)

Figure 12 - Attaching Flexible Gas Hose

to Heater Gas Regulator

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING:Aqualifiedservice personmustconnectheatertogas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This heater requires an external regu- lator (not supplied). Install the external regulator between the heater and propane/LP supply.

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes) (provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Propane/LP

External

Supply Tank

 

Regulator

Vent

 

Pointing

 

Down

 

Figure 13 - External Regulator With Vent

Pointing Down

116412-01B

www.desatech.com

13

Image 13
Contents Ansi Z21.11.2b-2004 Ansi Z21.60-2003 Models VFRMV18NB, VFRMV18PB VFRMV24NB and VFRMV24PBTable of Contents Safety Information Safety Information Product Features Optional Remote Control AccessoriesProduct Identification Local CodesProviding Adequate Ventilation Air For Combustion VentilationDetermining FRESH-AIR Flow For Appliance LocationVentilation AIR AIR for Combustion VentilationVentilation Air From Inside Building Ventilation Air From Outdoors InstallationCheck GAS Type Installation and Clearances for vent-free operationCeiling Minimum Noncombustible Material Clearances Safe InstallationFloor Clearances Mantel ClearancesInstalling Remote Control Accessory bracket Installing Damper Clamp Accessory for Vented OperationInstalling Heater Assembly Masonry Manufactured FireplaceFireplaceInstallation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Propane/LP FromPiping System Test Pressures In Excess Of 1/2 Psig KPa Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Operating HeaterPropane/LPNatural Shutting Off HeaterOptional Hand-Held Manual Lighting ProcedureRemote Operation On/Off Series Model HRC100Auto Shutoff Feature Safety FeaturesKey Pad Lock Feature Inspecting BurnersBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder Pilot Air Inlet Hole Wiring Diagram Cleaning MaintenanceTechnical Service Propane/LPObserved Problem Possible Cause Remedy TroubleshootingMaintenance, TroubleshootingOperation Processes and logs curing Hours of operation Checking Gas Connections Gas leak. See warningReplacement Parts SpecificationsService Hints AccessoriesAccessories Models VFRMV18NB, VFRMV18PB, VFRMV24NB Shown and VFRMV24PB Illustrated Parts BreakdownParts List 116412-01B 116412-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VFRMV18PB, VFRMV18NB, VFRMV24NB, VFRMV24PB specifications

The Desa VFRMV series is a sophisticated line of heating solutions known for its efficiency and modern design. The models in this series include the VFRMV24NB, VFRMV24PB, VFRMV18NB, and VFRMV18PB, each sharing a commitment to provide superior comfort and versatility in various living spaces.

One of the most notable features of the VFRMV series is its advanced heating technology. These units are equipped with a powerful burner system designed to maximize heat output while minimizing energy consumption. This makes the units not only environmentally friendly but also cost-effective, as users can enjoy warm indoor spaces without incurring high energy bills. The gas burners achieve a high thermal efficiency, ensuring that a significant amount of heat is delivered into the room promptly.

The VFRMV series is designed with customer convenience in mind. The models feature easy-to-read digital displays that allow users to adjust temperatures and settings effortlessly. These displays are intuitive, providing feedback on heating levels, operational status, and timer functions, enhancing the user experience. Furthermore, the inclusion of a remote control option allows homeowners to manage the heating from the comfort of their sitting area.

In terms of safety, the VFRMV series implements several key features. Each unit is equipped with an oxygen depletion sensor and a safety shut-off system. This ensures that the unit operates safely within its designated space, automatically shutting down if carbon monoxide levels rise or oxygen levels drop beyond safe limits. This commitment to safety provides peace of mind for households, making it a suitable choice for a wide range of environments.

Aesthetically, the VFRMV24NB and VFRMV24PB models feature a sleek design, with the "NB" models showcasing a bold black finish, while the "PB" variants offer a more classic propane-blue coloration. The smaller VFRMV18 series similarly combines elegance with functionality, ensuring that they can seamlessly blend into any home décor.

In summary, the Desa VFRMV24NB, VFRMV24PB, VFRMV18NB, and VFRMV18PB models exemplify modern heating solutions. With their advanced burner technology, user-friendly features, stringent safety measures, and stylish designs, they cater to contemporary requirements for effective indoor heating. Whether for residential or commercial use, the VFRMV series promises reliability and comfort all year round.