Desa VFRMV24NB, VFRMV24PB, VFRMV18NB Inspecting Burners, Pilot Flame Pattern, Safety Features

Page 19

OPERATING HEATER

Continued

4.Press the POWER and LOCK buttons together to turn off the fireplace.

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1. If the average room temperature exceeds 82° Fahrenheit (28° Centigrade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2. The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Digital Display Shows

 

Turns Hand-

Temperature and Settings

Held Remote

 

 

 

 

On or Off and

 

 

 

 

Allows You

 

 

 

 

to Choose

 

 

AUTO

the Manual

Locks

ROOM

 

SET

Setting

TEMP

 

TEMP

System to

 

 

 

 

Prevent

LOCK

TEMP

POWER

 

Accidental

 

 

 

 

Ignition

 

 

 

 

 

MANU

ºC/ºF

AUTO

 

 

 

 

 

Turns

 

 

 

 

Burners

 

 

 

Selects

On or Off

 

 

 

AUTO

 

 

 

 

Mode

Increases or Decreases

°C/°F Mode

Room Temperature in AUTO

Button

Mode

 

 

 

 

 

 

 

Figure 22 - Thermostat Hand-Held Remote Control Unit (HRC200)

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

Inspecting Burners

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 24

turn heater off (see To Turn Off Gas to Appli- ance, page 17)

see Troubleshooting, page 22

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Thermocouple

Figure 23 - Correct Pilot Flame Pattern (Your pilot may vary from pilot shown)

Pilot Burner

Thermocouple

Figure 24 - Incorrect Pilot Flame Pattern (Your pilot may vary from pilot shown)

116412-01B

www.desatech.com

19

Image 19
Contents Ansi Z21.11.2b-2004 Ansi Z21.60-2003 Models VFRMV18NB, VFRMV18PB VFRMV24NB and VFRMV24PBTable of Contents Safety Information Safety Information Local Codes Optional Remote Control AccessoriesProduct Features Product IdentificationFor Appliance Location Air For Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR FlowVentilation AIR AIR for Combustion VentilationVentilation Air From Inside Building Ventilation Air From Outdoors InstallationCheck GAS Type Installation and Clearances for vent-free operationCeiling Minimum Noncombustible Material Clearances Safe InstallationFloor Clearances Mantel ClearancesMasonry Manufactured FireplaceFireplace Installing Damper Clamp Accessory for Vented OperationInstalling Remote Control Accessory bracket Installing Heater AssemblyInstallation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Propane/LP FromPiping System Test Pressures In Excess Of 1/2 Psig KPa Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Heater For Your Safety Read Before LightingLighting Instructions Shutting Off Heater Operating HeaterTo Turn OFF GAS To Appliance Propane/LPNaturalOn/Off Series Model HRC100 Manual Lighting ProcedureOptional Hand-Held Remote OperationInspecting Burners Safety FeaturesAuto Shutoff Feature Key Pad Lock FeatureBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder Pilot Air Inlet Hole Propane/LP Cleaning MaintenanceWiring Diagram Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, TroubleshootingOperation Processes and logs curing Hours of operation Checking Gas Connections Gas leak. See warningAccessories SpecificationsReplacement Parts Service HintsAccessories Models VFRMV18NB, VFRMV18PB, VFRMV24NB Shown and VFRMV24PB Illustrated Parts BreakdownParts List 116412-01B 116412-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VFRMV18PB, VFRMV18NB, VFRMV24NB, VFRMV24PB specifications

The Desa VFRMV series is a sophisticated line of heating solutions known for its efficiency and modern design. The models in this series include the VFRMV24NB, VFRMV24PB, VFRMV18NB, and VFRMV18PB, each sharing a commitment to provide superior comfort and versatility in various living spaces.

One of the most notable features of the VFRMV series is its advanced heating technology. These units are equipped with a powerful burner system designed to maximize heat output while minimizing energy consumption. This makes the units not only environmentally friendly but also cost-effective, as users can enjoy warm indoor spaces without incurring high energy bills. The gas burners achieve a high thermal efficiency, ensuring that a significant amount of heat is delivered into the room promptly.

The VFRMV series is designed with customer convenience in mind. The models feature easy-to-read digital displays that allow users to adjust temperatures and settings effortlessly. These displays are intuitive, providing feedback on heating levels, operational status, and timer functions, enhancing the user experience. Furthermore, the inclusion of a remote control option allows homeowners to manage the heating from the comfort of their sitting area.

In terms of safety, the VFRMV series implements several key features. Each unit is equipped with an oxygen depletion sensor and a safety shut-off system. This ensures that the unit operates safely within its designated space, automatically shutting down if carbon monoxide levels rise or oxygen levels drop beyond safe limits. This commitment to safety provides peace of mind for households, making it a suitable choice for a wide range of environments.

Aesthetically, the VFRMV24NB and VFRMV24PB models feature a sleek design, with the "NB" models showcasing a bold black finish, while the "PB" variants offer a more classic propane-blue coloration. The smaller VFRMV18 series similarly combines elegance with functionality, ensuring that they can seamlessly blend into any home décor.

In summary, the Desa VFRMV24NB, VFRMV24PB, VFRMV18NB, and VFRMV18PB models exemplify modern heating solutions. With their advanced burner technology, user-friendly features, stringent safety measures, and stylish designs, they cater to contemporary requirements for effective indoor heating. Whether for residential or commercial use, the VFRMV series promises reliability and comfort all year round.