Desa R, V, T Optional Positioning of Thermostat Sensing Bulb, Thermostat-Controlled Models Only

Page 27

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB (THERMOSTAT-CONTROLLED MODELS ONLY)

For Masonry and Factory-Built Metal Fireplace

27

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

(Thermostat-Controlled Models Only)

FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located on the gas valve assembly. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For position- ing the thermostat sensing bulb elsewhere, an adhesive-backed mounting clip is available (see Figure 41).

Tools needed: 5/16" hex driver or socket

Capillary

 

 

Thermostat

 

 

Sensing

 

Screw

Bulb

 

Retaining Clamp

 

 

Figure 41 - Adhesive-backed

Figure 42 - Removing

Mounting Clip

Thermostat Sensing Bulb

1.

Locate the gas valve assembly and thermostat sensing bulb

 

(see Figure 40).

2.

With 5/16" hex driver or socket, loosen the thermostat screw.

 

Carefully slide the thermostat sensing bulb out of the retaining

 

clamp (see Figure 42).

 

Note: Do not remove the screw. Make sure you tighten the

 

screw after removing the thermostat sensing bulb.

 

IMPORTANT: Do not force or bend the thermostat sensing

 

bulb or capillary.

Thermostat Sensing Bulb

Adhesive- backed Mounting Clip

Thermostat Sensing Bulb

Adhesive- backed Mounting Clip

3. The thermostat sensing bulb may be located to the lower right

front side of fireplace. Determine location of sensing bulb, but

do not mount sensing bulb until step 5. If you have a masonry

fireplace, see Figure 43 for location.

If you have a factory-built metal fireplace, see Figure 44 for

location.

Figure 43 - Locating Thermostat

Figure 44 - Locating Thermostat

Sensing Bulb on Masonry

Sensing Bulb on Factory-built

Fireplace

Metal Fireplace

If your fireplace has glass doors, position sensing bulb directly

behind door gap on right bottom side (see Figure 45).

4. The mounting clip must be a minimum of 3" from bottom of

fireplace to prevent crimping of capillary. Once you have de-

cided on a location, clean the area thoroughly. Remove the pa-

per backing from the adhesive on back of mounting clip. Press

the clip into the new location so that the thermostat sensing bulb

will be positioned vertically with the capillary at the bottom (see

Figure 46). Slide the thermostat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Thermostat Sensing Bulb

Adhesive- backed Mounting Clip

Glass Doors

Thermostat Sensing Bulb

Adhesive- backed Mounting

Clip

Capillary

Do Not

Crimp Capillary

Gas Valve Assembly

Thermostat

Sensing Bulb

Figure 40 - Location of Gas Valve Assembly and Thermostat Sensing Bulb

Figure 45- Installing Thermostat

Figure 46 - Positioning the

Sensing Bulb behind Glass

Thermostat Sensing Bulb in

Doors

the Vertical Position with the

 

Capillary at the Bottom

For morevisit www..com

110882-01C

Image 27
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation and Clearances for VENT-FREE OperationCheck GAS Type Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base to Fireplace Floor Remote-Ready Models Only External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsInstalling Front Log #1 Lighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingControl Knob and Ignitor Button Location Pilot Propane/LP Pilot Natural Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Main Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceThermostat-Controlled Models Only Remote-Ready SpecificationsParts Under Warranty Wiring Diagram Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Variable MANUALLY-CONTROLLED Split OAK Models Parts ListTHERMOSTAT-CONTROLLED Models NVS18NT, NVS18PT THERMOSTAT-CONTROLLED Models Items 4 REMOTE-READY Variable Control Accessories Owners Registration Form Postage Required 110882-01C Warranty Information
Related manuals
Manual 32 pages 23.67 Kb