Desa R, V, T, 30 Check GAS Type, Installation and Clearances for VENT-FREE Operation

Page 7

INSTALLATION

Check Gas Type Installation and Clearances for Vent-Free Operation

7

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall heater. Follow all local codes.

NOTICE: State or local codes may only allow opera- tion of this appliance in a vented configuration. Check your state or local codes.

WARNING: Make sure the selector switch is in the OFF position before installing heater (Remote-Ready Models Only).

WARNING: Before installing in a solid fuel burn- ing fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney and firebox flue for damage. If damaged, repair flue and firebox before operating heater.

WARNING: Seal any fresh air vents or ash clean- out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom unless installed as a vented appliance, see page 10 (Remote-Ready and Variable Manually-Controlled Models Only)

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

INSTALLATION AND CLEARANCES FOR VENT-FREE OPERATION

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

18", 24", 30"

Side Wall

16"

 

 

Ceiling

42"

 

 

Floor

5"

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

Minimum Firebox Size

Log

 

 

Front

Rear*

Size

Height

Depth

Width

Width

18"

17"

14"

20"

14"

24"

17"

14"

26"

18"

30"

17"

14"

32"

22"

 

 

 

 

 

*Measured at 14" depth

For morevisit www..com

110882-01C

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base to Fireplace Floor Remote-Ready Models Only External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsInstalling Front Log #1 Lighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingControl Knob and Ignitor Button Location Pilot Propane/LP Pilot Natural Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Main Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbThermostat-Controlled Models Only Remote-Ready SpecificationsParts Under Warranty Wiring Diagram Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Variable MANUALLY-CONTROLLED Split OAK Models Parts ListTHERMOSTAT-CONTROLLED Models NVS18NT, NVS18PT THERMOSTAT-CONTROLLED Models Items 4 REMOTE-READY Variable Control Accessories Owners Registration Form Postage Required 110882-01C Warranty Information