SPECIFICATIONS

SPECIFICATIONS

 

18" Thermostat-Controlled

24" Thermostat-Controlled

30" Thermostat-Controlled

Btu (Variable)

16,000/29,000 - 16,000/26,000

20,000/33,000

21,500/36,000

Type Gas

Propane/LP Only - Natural

Propane/LP Only - Natural

Propane/LP Only - Natural

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

7.9" W.C. - 3.4" W.C.

7.9" W.C. - 3.4" W.C.

7.9" W.C. - 3.4" W.C.

Inlet Gas Pressure

 

 

 

(in. of water)

 

 

 

Maximum

14" - 10.5"

14" - 10.5"

14" - 10.5"

Minimum*

11" - 5"

11" - 5"

11" - 5"

Shipping Weight

26 lbs.

30 lbs.

34 lbs.

* For purpose of input adjustment

 

 

 

18" Variable

24" Variable

30" Variable

 

Manually-Controlled

Manually-Controlled

Manually-Controlled

Btu (Variable)

16,000/29,000 - 16,000/26,000

20,000/33,000

21,500/36,000

Type Gas

Propane/LP Only - Natural

Propane/LP Only - Natural

Propane/LP Only - Natural

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

7.9" W.C. - 3.4" W.C.

7.9" W.C. - 3.4" W.C.

7.9" W.C. - 3.4" W.C.

Inlet Gas Pressure

 

 

 

(in. of water)

 

 

 

Maximum

14" - 10.5"

14" - 10.5"

14" - 10.5"

Minimum*

11" - 5"

11" - 5"

11" - 5"

Shipping Weight

26 lbs.

30 lbs.

34 lbs.

* For purpose of input adjustment

 

 

 

18" Remote-Ready

24" Remote-Ready

30" Remote-Ready

Btu (Variable)

16,000/29,000 - 16,000/26,000

20,000/33,000

21,500/36,000

Type Gas

Propane/LP Only - Natural

Propane/LP Only - Natural

Propane/LP Only - Natural

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

7.9" W.C. - 3.4" W.C.

7.9" W.C. - 3.4" W.C.

7.9" W.C. - 3.4" W.C.

Inlet Gas Pressure (in. of water)

 

 

Maximum

14" - 10.5"

14" - 10.5"

14" - 10.5"

Minimum*

11" - 5"

11" - 5"

11" - 5"

Shipping Weight

32 lbs.

34 lbs.

36 lbs.

* For purpose of input adjustment

For..com

110882-01C

Image 28
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product IdentificationOptional Remote Control Accessories Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type If Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesAttaching Base to Fireplace Floor Remote-Ready Models Only Connecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Front Log #1 Operating Heater Lighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Variable Control OperationControl Knob and Ignitor Button Location Optional HAND-HELD Remote Operation Pilot Propane/LP Pilot NaturalManual Mode Auto Thermostatic ModeSafety Features ON/OFF Series Model GhrcbPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Main BurnerTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbThermostat-Controlled Models Only Specifications Remote-ReadyWiring Diagram Replacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Split OAK ModelsTHERMOSTAT-CONTROLLED Models NVS18NT, NVS18PT THERMOSTAT-CONTROLLED Models Items 4 REMOTE-READY Variable Control Accessories Owners Registration Form Postage Required 110882-01C Warranty Information