Desa R, V, T, 30 installation manual Control Knob and Ignitor Button Location

Page 19

OPERATING HEATER (REMOTE-READY MODELS)

For Your Safety Read Before Lighting (Cont.) Lighting Instructions

19

OPERATING HEATER

Continued

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Make sure there are no obxtructions across openings of fireplace.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, starting in column 2, page 18.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in the OFF position.

4.Press in and turn control knob clockwise to the OFF position (see Figure 28).

WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, starting in column 2, page 18. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 28).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button un- til pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 20.

Control Knob

O

O

L

IL T

O

P

 

F

N

 

 

 

F

 

 

O

 

 

 

HI

AUTO

 

 

OFF

 

 

ON

Ignitor Button

Flame

Selector Switch

Adjustment

in OFF Position

 

Knob

 

 

Figure 28 - Control Knob and Ignitor Button Location

For morevisit www..com

110882-01C

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base to Fireplace Floor Remote-Ready Models Only External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsInstalling Front Log #1 Lighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingControl Knob and Ignitor Button Location Pilot Propane/LP Pilot Natural Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Main Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbThermostat-Controlled Models Only Remote-Ready SpecificationsParts Under Warranty Wiring Diagram Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Variable MANUALLY-CONTROLLED Split OAK Models Parts ListTHERMOSTAT-CONTROLLED Models NVS18NT, NVS18PT THERMOSTAT-CONTROLLED Models Items 4 REMOTE-READY Variable Control Accessories Owners Registration Form Postage Required 110882-01C Warranty Information
Related manuals
Manual 32 pages 23.67 Kb