Desa CGD3924N Installing Damper Clamp Accessory for Vented Operation, Attaching Damper Clamp

Page 13

INSTALLING

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid- fuel burning fireplace with a working flue and constructed of non combustible material.

If your heater is a manually controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles requirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 29). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Area of Various Standard Round Flues

Diameter (ins.)

Area (sq. ins.)

 

 

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

 

 

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

 

 

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

 

 

Damper

Clamp

Damper

Damper

Clamp

Damper

Damper

Masonry Fireplace

Manufactured Fireplace

Figure 10 - Attaching Damper Clamp

102828

Continued

13

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Burner patterns can cause sooting Safety Device Local Codes Unpacking Product FeaturesOperation Piezo Ignition SystemVentilation AIR forProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Tion and ventilation air by one of the methods described Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type InstallingTo Combustible Materials Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Wall and Ceiling Clearances see FigureMinimum Non Combustible Material Clearances Log Set Installing Minimum Non Combustible Material ClearancesFloor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyMounting Bracket Connecting to GAS Supply Gas Connection Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsInstalling Logs InstallingOperating Heater For Your Safety Read Before LightingOperating HeaterPilot Flame Pattern Operating Heater Inspecting BurnersMaintenance CleaningTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting Maintenance,Refer to Air for Com Gas leak. See Warning Service Hints Technical ServiceModel Parts Not Under Warranty Parts Under WarrantyParts Central Valve GA5010 AccessoriesHood GA6050 Hood GA6052Illustrated Parts Breakdown KEY Part Number Description QTY Parts ListKeep this Warranty Warranty Information