Desa CGD3924N installation manual Local Codes Unpacking Product Features, Operation, Safety Device

Page 4

PRODUCT IDENTIFICATION

LOCAL CODES

UNPACKING

PRODUCT

FEATURES

4

Crossover Log

Back Log

Front Log

 

Burner

Piezo

Middle Log

Ignitor

 

 

Control Knob

 

Base Grate

 

Figure 1 - Vent-Free Gas Log Heater

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.

*Available from: American National Standards Institute, Inc. 1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

Operation

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. You can operate heater as a vented product by opening flue damper.

Safety Device

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

102828

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Burner patterns can cause sooting Local Codes Unpacking Product Features Safety DeviceOperation Piezo Ignition SystemVentilation AIR forProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Tion and ventilation air by one of the methods describedVentilation Air From Inside Building Ventilation Air From OutdoorsInstalling Check GAS TypeMinimum Fireplace Clearance To Combustible MaterialsLOG Sizing Requirements Minimum Wall and Ceiling Clearances see FigureMinimum Non Combustible Material Clearances Installing Minimum Non Combustible Material Clearances Log SetFloor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededMounting Bracket Connecting to GAS Supply Checking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Installing LogsFor Your Safety Read Before Lighting Operating HeaterHeater OperatingOperating Heater Inspecting Burners Pilot Flame PatternCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Service Hints Technical ServiceModel Parts Not Under Warranty Parts Under WarrantyParts Central Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Breakdown Parts List KEY Part Number Description QTYWarranty Information Keep this Warranty