INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue for damage. If damaged, operate heater with flue damper closed.

WARNING: Seal any fresh air vents or ash clean-out doors lo- cated on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance (Variable Manually- Controlled Models Only) (see page 10)

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND

CLEARANCES (Vent-Free

Operation Only)

WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

Ceiling

18", 24", 30"

16"

 

 

42"

 

 

 

 

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

Minimum Firebox Size

Log

 

 

 

Front

Rear*

Size

Height

 

Depth

Width

Width

18"

17"

 

14"

24"

 

20"

24"

17"

 

14"

28"

 

21"

30"

17"

 

14"

34"

 

24"

 

 

 

 

 

 

 

*Measured at 14" Depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or cer- tified vent-free firebox.

Continued

107123

7

For more information, visit www.desatech.com

Image 7
Contents CGD3924N CY3124N What to do if YOU Smell GASCGD3930N VENT-FREE Natural GAS LOG Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation Safety PilotAIR for Combustion and Ventilation Piezo Ignition SystemDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Minimum Fireplace Clearance To Combustible Materials InstallationInstallation Check GAS TypeMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesChimney Installing Damper Clamp Accessory for Vented OperationHeight ft Flue Opening sq. ins Installation Items Needed Installing Heater Base AssemblyGas Connection Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping systemChecking GAS Connections Dual Burner Smoky Mountain Oak Models Installing LogsDual Burner Premium Aged Split Oak Models Installing Back Log #2Front Log #1 Grate Fingers Grate Base Dual Burner Biltmore Split Oak ModelsSingle Burner Mountain Oak Models Installing Crossover Log #6 CCL3930NTA ShownOperating Heater For Your Safety Read Before LightingLighting Instructions Shutting Off Heater Manual Lighting ProcedureVariable Control Operation To Turn OFF GAS To AppliancePilot Flame Pattern Inspecting BurnersThermostat Control Operation Main Burner Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at top TopFor Masonry and Factory- built Metal Fireplace Optional Positioning of Thermostat Sensing BulbService Hints Replacement PartsSpecifications Fireplace Hood Technical ServiceAccessories Parts CentralIllustrated Parts Breakdown CGD3018N CGD3924N CGD3930N Parts ListThermostatically-Controlled Premium Aged Split Oak Models CGB3924NT CGB3930NTCGB3924NT CGB3930NT CGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT Thermostatically-Controlled Biltmore Split Oak Model CCL3018NTCCL3018NT CCL3924NT CCL3924NT CCL3930NTA CCL3930NTA Variable Manually-Controlled Mountain Oak Models CY2718N CY3124N Keep this Warranty Warranty Information

CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT specifications

Desa has garnered significant attention in the heating industry with its impressive lineup of products, specifically the CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, and CCL3930NT. These models showcase a blend of efficiency, functionality, and aesthetic appeal, catering to diverse residential and commercial heating needs.

The CGD3924NT and CGD3930NT are designed as gas fireplaces that enhance indoor spaces while offering superior performance. The CGD3924NT features an elegant design with a 24-inch burning area, conceived to generate efficient heat while maintaining an inviting ambiance. Its straightforward controls allow users to adjust heat levels effortlessly. Conversely, the CGD3930NT extends a bit larger with a 30-inch burning area, strategizing for more extensive heating requirements in larger spaces without sacrificing style or efficiency.

Turning to the CGB series, the CGB3924NT and CGB3930NT models emphasize versatility along with a striking appearance. These gas-burning fireplaces are engineered to provide reliable performance and can easily integrate into a variety of home designs. Both models feature advanced safety measures, including an automatic shut-off system and durable construction that ensures longevity.

For those seeking a classic, timeless look, the CCL series offers the CCL3018NT, CCL3924NT, and CCL3930NT models. These corner gas logs are designed for minimal aesthetic disruption, providing warmth from a unique angle. The CCL3018NT serves well for modest spaces, while the CCL3924NT and CCL3930NT cater to larger areas, focusing on enhanced heat distribution without overwhelming the room's decor.

Across the range, energy efficiency is a signature characteristic, with advanced heating technologies like electronic ignition and variable flame control that optimize fuel usage without compromising output. Each model proudly bears compliance with industry safety standards, ensuring user peace of mind.

In conclusion, the Desa series – consisting of the CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, and CCL3930NT – embodies technological advancement with a commitment to user-friendliness and style. These products are designed to not only heat spaces effectively but also add a touch of sophistication and comfort to any environment. With a focus on reliability and aesthetics, Desa continues to stand at the forefront of heating solutions.