Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT

Page 10

VENT-FREE NATURAL GAS LOG HEATER

INSTALLATION

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If your heater is a manually-controlled model, you may use this heater as a vented product. There are three reasons for operat- ing your heater in the vented mode.

1.The fireplace does not meet the clear- ance to combustibles requirements for vent-free operation.

2.State or local codes do not permit vent- free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 27). This will insure vented operation (see Figure 11). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Area of Various Standard

Round Flues

Diameter (ins.)

Area (sq. ins.)

 

 

 

5"

 

20 sq. inches

6"

 

29 sq. inches

7"

 

39 sq. inches

8"

 

51 sq. inches

 

 

 

 

 

 

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

 

 

 

6' to 15'

 

39 sq. inches

15' to 30'

 

29 sq. inches

 

 

 

Damper

Clamp

Damper

Damper

Clamp

Damper

Damper

Masonry Fireplace

Manufactured Fireplace

Figure 11 - Attaching Damper Clamp

For more information, visit www.desatech.com

10

107123

Image 10
Contents CGD3924N CY3124N What to do if YOU Smell GASCGD3930N Safety Information VENT-FREE Natural GAS LOG HeaterLocal Codes Product FeaturesProduct Identification UnpackingPiezo Ignition System Safety PilotAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Minimum Fireplace Clearance To Combustible MaterialsIf Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceChimney Installing Damper Clamp Accessory for Vented OperationHeight ft Flue Opening sq. ins Installing Heater Base Assembly Installation Items NeededConnecting to GAS Supply Gas ConnectionPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping systemChecking GAS Connections Installing Logs Dual Burner Smoky Mountain Oak ModelsInstalling Back Log #2 Dual Burner Premium Aged Split Oak ModelsDual Burner Biltmore Split Oak Models Front Log #1 Grate Fingers Grate BaseInstalling Crossover Log #6 CCL3930NTA Shown Single Burner Mountain Oak ModelsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureVariable Control Operation Shutting Off HeaterPilot Flame Pattern Inspecting BurnersThermostat Control Operation Burner Primary AIR Holes Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement at topOptional Positioning of Thermostat Sensing Bulb For Masonry and Factory- built Metal FireplaceService Hints Replacement PartsSpecifications Parts Central Technical ServiceAccessories Fireplace HoodIllustrated Parts Breakdown Parts List CGD3018N CGD3924N CGD3930NCGB3924NT CGB3930NT Thermostatically-Controlled Premium Aged Split Oak ModelsCGB3924NT CGB3930NT CGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT CCL3018NT Thermostatically-Controlled Biltmore Split Oak ModelCCL3018NT CCL3924NT CCL3924NT CCL3930NTA CCL3930NTA Variable Manually-Controlled Mountain Oak Models CY2718N CY3124N Warranty Information Keep this Warranty

CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT specifications

Desa has garnered significant attention in the heating industry with its impressive lineup of products, specifically the CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, and CCL3930NT. These models showcase a blend of efficiency, functionality, and aesthetic appeal, catering to diverse residential and commercial heating needs.

The CGD3924NT and CGD3930NT are designed as gas fireplaces that enhance indoor spaces while offering superior performance. The CGD3924NT features an elegant design with a 24-inch burning area, conceived to generate efficient heat while maintaining an inviting ambiance. Its straightforward controls allow users to adjust heat levels effortlessly. Conversely, the CGD3930NT extends a bit larger with a 30-inch burning area, strategizing for more extensive heating requirements in larger spaces without sacrificing style or efficiency.

Turning to the CGB series, the CGB3924NT and CGB3930NT models emphasize versatility along with a striking appearance. These gas-burning fireplaces are engineered to provide reliable performance and can easily integrate into a variety of home designs. Both models feature advanced safety measures, including an automatic shut-off system and durable construction that ensures longevity.

For those seeking a classic, timeless look, the CCL series offers the CCL3018NT, CCL3924NT, and CCL3930NT models. These corner gas logs are designed for minimal aesthetic disruption, providing warmth from a unique angle. The CCL3018NT serves well for modest spaces, while the CCL3924NT and CCL3930NT cater to larger areas, focusing on enhanced heat distribution without overwhelming the room's decor.

Across the range, energy efficiency is a signature characteristic, with advanced heating technologies like electronic ignition and variable flame control that optimize fuel usage without compromising output. Each model proudly bears compliance with industry safety standards, ensuring user peace of mind.

In conclusion, the Desa series – consisting of the CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, and CCL3930NT – embodies technological advancement with a commitment to user-friendliness and style. These products are designed to not only heat spaces effectively but also add a touch of sophistication and comfort to any environment. With a focus on reliability and aesthetics, Desa continues to stand at the forefront of heating solutions.