14.Turn heater off and let cool before ser- vicing. Only a qualified service person should service and repair heater.

15.Operating heater above elevations of 4,500 feet could cause pilot outage.

PRODUCT IDENTIFICATION

Crossover Log

Back Log

Front Log

 

Burner

Piezo

Middle Log

Ignitor

 

Control Knob

Base Grate

Figure 1 - Vent-Free Gas Log Heater - Duel Burner (Logs May Vary by Model - Smoky Mountain Oak Logs Shown)

Back Log

Crossover Log

Front Log

Burner

Piezo

Ignitor

Control Knob

Figure 2 - Vent-Free Gas Log Heater - Single Burner (Mountain Oak Logs Shown)

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat models are not permitted.

UNPACKING

CAUTION: Do not remove the metal data plates from the grate assembly. The data plates contain important product information.

1.Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging ap- plied to logs and heater for shipment.

3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.

PRODUCT

FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. Non-thermostat models may also be operated as a vented decorative (ANS Z21.60) product by opening flue damper.

107123

3

For more information, visit www.desatech.com

Image 3
Contents What to do if YOU Smell GAS CGD3924N CY3124NCGD3930N VENT-FREE Natural GAS LOG Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation Safety PilotAIR for Combustion and Ventilation Piezo Ignition SystemAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Minimum Fireplace Clearance To Combustible Materials InstallationInstallation Check GAS TypeMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation ChimneyHeight ft Flue Opening sq. ins Installation Items Needed Installing Heater Base AssemblyGas Connection Connecting to GAS SupplyPressure Testing Gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Dual Burner Smoky Mountain Oak Models Installing LogsDual Burner Premium Aged Split Oak Models Installing Back Log #2Front Log #1 Grate Fingers Grate Base Dual Burner Biltmore Split Oak ModelsSingle Burner Mountain Oak Models Installing Crossover Log #6 CCL3930NTA ShownFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Manual Lighting ProcedureVariable Control Operation To Turn OFF GAS To ApplianceInspecting Burners Pilot Flame PatternThermostat Control Operation Main Burner Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at top TopFor Masonry and Factory- built Metal Fireplace Optional Positioning of Thermostat Sensing BulbReplacement Parts Service HintsSpecifications Fireplace Hood Technical ServiceAccessories Parts CentralIllustrated Parts Breakdown CGD3018N CGD3924N CGD3930N Parts ListThermostatically-Controlled Premium Aged Split Oak Models CGB3924NT CGB3930NTCGB3924NT CGB3930NT CGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT Thermostatically-Controlled Biltmore Split Oak Model CCL3018NTCCL3018NT CCL3924NT CCL3924NT CCL3930NTA CCL3930NTA Variable Manually-Controlled Mountain Oak Models CY2718N CY3124N Keep this Warranty Warranty Information

CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT specifications

Desa has garnered significant attention in the heating industry with its impressive lineup of products, specifically the CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, and CCL3930NT. These models showcase a blend of efficiency, functionality, and aesthetic appeal, catering to diverse residential and commercial heating needs.

The CGD3924NT and CGD3930NT are designed as gas fireplaces that enhance indoor spaces while offering superior performance. The CGD3924NT features an elegant design with a 24-inch burning area, conceived to generate efficient heat while maintaining an inviting ambiance. Its straightforward controls allow users to adjust heat levels effortlessly. Conversely, the CGD3930NT extends a bit larger with a 30-inch burning area, strategizing for more extensive heating requirements in larger spaces without sacrificing style or efficiency.

Turning to the CGB series, the CGB3924NT and CGB3930NT models emphasize versatility along with a striking appearance. These gas-burning fireplaces are engineered to provide reliable performance and can easily integrate into a variety of home designs. Both models feature advanced safety measures, including an automatic shut-off system and durable construction that ensures longevity.

For those seeking a classic, timeless look, the CCL series offers the CCL3018NT, CCL3924NT, and CCL3930NT models. These corner gas logs are designed for minimal aesthetic disruption, providing warmth from a unique angle. The CCL3018NT serves well for modest spaces, while the CCL3924NT and CCL3930NT cater to larger areas, focusing on enhanced heat distribution without overwhelming the room's decor.

Across the range, energy efficiency is a signature characteristic, with advanced heating technologies like electronic ignition and variable flame control that optimize fuel usage without compromising output. Each model proudly bears compliance with industry safety standards, ensuring user peace of mind.

In conclusion, the Desa series – consisting of the CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, and CCL3930NT – embodies technological advancement with a commitment to user-friendliness and style. These products are designed to not only heat spaces effectively but also add a touch of sophistication and comfort to any environment. With a focus on reliability and aesthetics, Desa continues to stand at the forefront of heating solutions.