Desa 15, 000 to 30 Connecting to GAS Supply, External Regulator with Vent Pointing Down

Page 12

VENT-FREE PROPANE/LP HEATER

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an ex- ternal regulator (not supplied). In- stall the external regulator between the heater and propane/LP supply.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommenc that you install a sediment trap in supply line as shown in Figure 21. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

Note: Burner bracket not shown for clarity

incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

20.Pointing the vent down protects it from freezing rain or sleet.

External

Regulator

Propane/LP

Supply Tank

Vent Pointing Down

Test

Gauge

Connection *

Sediment

Trap

Pressure Regulator

3/8" NPT Pipe Nipple

Tee Joint

Reducer Bushing to 1/8" NPT

1/8" NPT Plug Tap

Tee Joint

Pipe

Nipple

Cap

Ground

Heater

Union

Cabinet

Joint

 

Equipment

Shutoff

Valve *

From External

Regulator (11"

W.C. to 14"W.C.

Pressure)

3" Minimum

Figure 20 - External Regulator with Vent Pointing Down

Figure 21 - Gas Connection

*An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design- certified equipment shutoff valve from your dealer. See Accessories, page 21.

12

104434

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GAS15,000 to 30,000 Btu/Hr With Thermostat Safety Information VENT-FREE PROPANE/LP HeaterProduct Features Product IdentificationLocal Codes UnpackingAssembly Installing LogAssembling Heater Removing Front Panel Of HeaterAIR for Combustion and Ventilation Providing Adequate VentilationAssembling and Attaching Brass Trim Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation Items Locating HeaterCheck GAS Type Installation Options Thermostat Sensing BulbMounting Heater to Wall Installing Bottom Mounting Screws Mounting Heater on Optional Hearth BaseAttaching Mounting Bracket to Wall Placing Heater On Mounting BracketSecuring Hearth Base to Floor See Instructions Included With Mantel Kit Assembling MantelMounting Heater to Optional Hearth Base Connecting to GAS Supply External Regulator with Vent Pointing DownPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Inspecting BurnerThermostat Control Operation Pilot Flame PatternCleaning and Maintenance Replacement PartsService Hints Troubleshooting Observed Problem Possible Cause Gas odor even when control knob is in OFF Lation requirementsSpecifications Technical ServiceParts Centrals Accessories Illustrated Parts Breakdown RFP30TParts List KEY Part Number DescriptionWarranty Information Model Serial No Date Purchased