Desa 15, 000 to 30 installation manual Observed Problem Possible Cause

Page 18

VENT-FREE PROPANE/LP HEATER

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice is clogged

 

2.

Burner orifice diameter is too small

 

3.

Inlet gas pressure is too low

1.Clean burner (see Cleaning and Mainte- nance, page 16) or replace burner orifice

2.Replace burner orifice

3.Contact local propane/LP gas company

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 16) or replace burner orifice

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

 

2.

Burner damaged

 

3.

Gas regulator defective

1.Clean burner (see Cleaning and Mainte- nance, page 16) or replace burner orifice

2.Replace burner

3.Replace gas regulator

Yellow flame during burner combustion

1.

Not enough air

 

2.

Gas regulator defective

1.Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 16)

2.Replace gas regulator

Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of operation

Heater produces a whistling noise when burner is lit

1.Turning control knob to HI position when burner is cold

2.Air in gas line

3.Air passageways on heater blocked

4.Dirty or partially clogged burner orifice

1.Turn control knob to LO position and let warm up for a minute

2.Operate burner until air is removed from line. Have gas line checked by local pro- pane/LP gas company

3.Observe minimum installation clear- ances (see Figure 10, page 8)

4.Clean burner (see Cleaning and Mainte- nance, page 16) or replace burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

18

104434

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GAS15,000 to 30,000 Btu/Hr With Thermostat Safety Information VENT-FREE PROPANE/LP HeaterLocal Codes Product FeaturesProduct Identification UnpackingAssembling Heater AssemblyInstalling Log Removing Front Panel Of HeaterAssembling and Attaching Brass Trim AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation Items Locating HeaterCheck GAS Type Installation Options Thermostat Sensing BulbMounting Heater to Wall Attaching Mounting Bracket to Wall Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Placing Heater On Mounting BracketSecuring Hearth Base to Floor See Instructions Included With Mantel Kit Assembling MantelMounting Heater to Optional Hearth Base Connecting to GAS Supply External Regulator with Vent Pointing DownPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Pilot Flame PatternCleaning and Maintenance Replacement PartsService Hints Troubleshooting Observed Problem Possible Cause Gas odor even when control knob is in OFF Lation requirementsSpecifications Technical ServiceParts Centrals Accessories Illustrated Parts Breakdown RFP30TParts List KEY Part Number DescriptionWarranty Information Model Serial No Date Purchased