Desa 15, 000 to 30 Assembly, Assembling Heater, Removing Front Panel Of Heater, Installing Log

Page 4

VENT-FREE PROPANE/LP HEATER

ASSEMBLY

ASSEMBLING HEATER

Tools Required:

Phillips Screwdriver

5/16" hex wrench

Slotted screwdriver

Removing Front Panel Of Heater

1.Remove two screws near bottom cor- ners of front panel with Phillips screw- driver.

2.Pull bottom of front panel forward, then down (see Figure 2) .

Installing Log

Note: For easier installation, lay heater on its back.

1.Remove log from inside top of heater. Discard protective packaging.

2.Attach ignitor cable to piezo ignitor (see Figure 3).

3.With Phillips screwdriver, remove four screws holding screen in place. Re- move screen.

4.Gently slide log between log retaining brackets on deflector assembly (see Fig- ure 4). The log should fit firmly against bottom of log retaining brackets.

5.Reattach screen using four screws re- moved in step 3.

WARNING: Always have burner shield and screen in place before operating heater. This pre- vents excessive temperatures on heater surfaces.

Failure to position the parts in accordance with these diagrams or failure to use only parts spe- cifically approved with this heater may result in property damage or personal injury.

Figure 2 - Removing Front Panel of Heater

Log

Screen

Front Panel

Truss

Head

Screw

Nut

Brass

Front Trim

Screw

Figure 4 - Assembling Heater

Attaching Brass Front Trim to Front Panel

1.Locate brass front trim in brass trim package.

2.Slide the head of two truss-head screws from hardware packet into each end of brass front trim (see Figure 5).

3.Line up screws with holes in front panel (see Figure 4). Insert screws in holes. Attach nuts from inside of front panel. Tighten with wrench.

Piezo Ignitor

Ignitor

Cable

Figure 3 - Attaching Ignitor Cable to Piezo Ignitor

Heater Cabinet

Deflector

Log

Retaining

Brackets

Burner Shield

Screw

Brass Front

Front Panel

Trim

Nut

Truss-Head

Screw

Figure 5 - Attaching Brass Front Trim to Front Panel

4

104434

Image 4
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual15,000 to 30,000 Btu/Hr With Thermostat Safety Information VENT-FREE PROPANE/LP HeaterProduct Features Product IdentificationLocal Codes UnpackingAssembly Installing LogAssembling Heater Removing Front Panel Of HeaterAIR for Combustion and Ventilation Providing Adequate VentilationAssembling and Attaching Brass Trim Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items Locating Heater InstallationCheck GAS Type Thermostat Sensing Bulb Installation OptionsMounting Heater to Wall Installing Bottom Mounting Screws Mounting Heater on Optional Hearth BaseAttaching Mounting Bracket to Wall Placing Heater On Mounting BracketSee Instructions Included With Mantel Kit Assembling Mantel Securing Hearth Base to FloorMounting Heater to Optional Hearth Base Connecting to GAS Supply External Regulator with Vent Pointing DownPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Inspecting BurnerThermostat Control Operation Pilot Flame PatternReplacement Parts Cleaning and MaintenanceService Hints Troubleshooting Observed Problem Possible Cause Gas odor even when control knob is in OFF Lation requirementsTechnical Service SpecificationsParts Centrals Accessories Illustrated Parts Breakdown RFP30TParts List KEY Part Number DescriptionWarranty Information Model Serial No Date Purchased