INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC INSTANTANEOUS TYPE WATER HEATERS FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS

MODEL 125HX LP and 125HX NG

(Flow Modulated with Electronic Ignition)

Suitable for heating potable water only

Not approved for space heating purposes

Intended for variable flow applications with steady cold water inlet temperatures.

6 720 606 804 US (04.11) AL

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

Upon completion of the installation, these instructions should be handed to the user of the appliance for future reference.

In the Commonwealth of Massachusetts this product must be installed by a licensed plumber or gas fitter.

WARNING

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable, combustible or corrosive vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance.

-Do not touch any electrical switch; do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency or the gas supplier.

TABLE OF CONTENTS

Specifications

Page 3

Rules for safe operation

Page 5

Locating the Heater

Page 5

Combustion Air Requirements

Page 6

Mounting the Heater

Page 6

Venting the Heater

Page 7

Gas Connections

Page 9

Gas Piping

Page 10

Water Connections

Page 11

Safety before turning on the heater

Page 11

Operating instructions

Page 12

Setting water temperature

Page 12

Maintenance & Service

Page 13

Trouble Shooting

Page 13

Electrical Diagram

Page 15

Diagram of 125HX

Page 17

Interior components diagram

Page 18

Parts List

Page 19

Flowchart

Page 20

Warranty

Page 21

Image 1
Contents Table of Contents For Your SafetyWhat to do if YOU Smell GAS 720 606 Unpacking the 125 HX Heater FeaturesPrinciple of Operation Required Natural Gas Pressure at inletTOP a Front B Back Sides Floor C Vent Diameter Front View Side ViewGeneral Rules to Follow For Safe Operation Proper Location for Installing Your HeaterCombustion AIR Requirements Mounting InstallationClearances Plasterboard, can cause failure of mounting VentingVent pipe connection Existing Interior Masonry Chimney Masonry ChimneysTile Lined Interior Masonry Chimney GAS Line Sizing GAS Connections6 Adaptor Used on High Altitude 10.5For LP GAS For Natural GASSource National Fuel Gas Code Nfpa 54, Ansi Z223.1 Water Connections For Your Safety Read Before Operating Your HOT Water HeaterOperating Instructions Lighting and Operating Instructions Setting the Water TemperatureTo Turn OFF GAS to Appliance Trouble Shooting Maintenance and ServiceReview Maintenance Table on the Back of this Manual Not enlarge the orificeNo Spark AT the Pilot Pilot Lights but Burners will not Come on Ground water temperature is very warmMain Burners GO OUT During HOT Water USE Water is TOO HOTHOT Water Temperature Fluctuates / Unit Deactivated Diagram of 125 HX Interior Components Diagram and Parts List Interior Components Diagram Parts List 125 HX Flow chart of 125 HX General Twelve Year Limited Warranty720 606 720 606 Controlled Energy Corp Maintenance Table see