HOT WATER TEMPERATURE FLUCTUATES / UNIT DEACTIVATED

1. Unbalanced pressure in waterlines

The added restriction caused by the 125 HX in the hot water system can result in uneven pressures between the cold and the hot. In such cases when mixing cold water at the tap, the lower hot water pressure may be overpowered by a much higher cold water pressure, which may cause the 125 HX burners to shut down. Make sure faucet aerators or shower heads are free of minerals. Do not add any flow restrictor to the shower head.

2. Temperature balance valves

If the inlet water temperature to the water heater is very warm the heater can produce temperatures that may be found to be too hot. A temperature balance shower valve can automatically mix in cold water to reduce such hot water temperature, in the event of any temperature instability with the use of a temperature balance shower valve, refer to shower valve manufactures instructions for internal adjustment setting. Adjustments should be made to the hottest setting in the shower valve. Additionally the temperature control of the heater can be adjusted to produce a more comfortable hot water temperature. See SETTING THE WATER TEMPERATURE section.

3.Cold water is mixing with the hot water between the 125 HX and the outlet

See #2 under “NO SPARK AT THE PILOT”.

4.Inlet water pressure is erratic due to inadequate supply water pressure or saturated pressure tank on well system

Check the inlet water pressure. For installation on a private well system with the use of a pressure tank, the lowest pressure range setting recommended is 30-50 psi (2.07 - 3.45 bar). Confirm that the pressure tank is not water logged.

5. Gas pressure is too low

See page 3 for correct specifications.

16

6 720 606 804

Image 16
Contents Table of Contents For Your SafetyWhat to do if YOU Smell GAS 720 606 Features Unpacking the 125 HX HeaterPrinciple of Operation Required Natural Gas Pressure at inletFront View Side View TOP a Front B Back Sides Floor C Vent DiameterProper Location for Installing Your Heater General Rules to Follow For Safe OperationCombustion AIR Requirements Mounting InstallationClearances Plasterboard, can cause failure of mounting VentingVent pipe connection Existing Interior Masonry Chimney Masonry ChimneysTile Lined Interior Masonry Chimney GAS Connections GAS Line Sizing6 Adaptor Used on High Altitude 10.5For LP GAS For Natural GASSource National Fuel Gas Code Nfpa 54, Ansi Z223.1 Water Connections For Your Safety Read Before Operating Your HOT Water HeaterOperating Instructions Lighting and Operating Instructions Setting the Water TemperatureTo Turn OFF GAS to Appliance Maintenance and Service Trouble ShootingReview Maintenance Table on the Back of this Manual Not enlarge the orificeNo Spark AT the Pilot Ground water temperature is very warm Pilot Lights but Burners will not Come onMain Burners GO OUT During HOT Water USE Water is TOO HOTHOT Water Temperature Fluctuates / Unit Deactivated Diagram of 125 HX Interior Components Diagram and Parts List Interior Components Diagram Parts List 125 HX Flow chart of 125 HX Twelve Year Limited Warranty General720 606 720 606 Maintenance Table see Controlled Energy Corp