Bosch Appliances GWH 2400 ES LP, GWH 2400 ES NG manual Description Minimum distance

Page 10

Installation instructions

Recommended exhaust vent terminator position

Fig. 10

Ref.

Description

Minimum distance

 

 

 

A

Directly below an opening; operable windows, doors and any non-

36 in (twin pipe installation)

mechanical fresh air openings

48 in (single pipe installation)

 

 

 

 

 

Below a gutter, sanitary pipework or eaves

24 in

B

Below a gutter, sanitary pipework or eaves, protected by metal

12 in

 

shielding

 

 

 

 

 

C

From any internal corner

12 in

D*

Above ground or snow pack

12 in

 

 

Above a paved sidewalk

7 ft

 

E

From an opposing wall or structure facing the termination

24 in

 

 

From the relief valve of a Ip gas regulator

60 in

 

F

From a terminator facing a terminator

48 in

G

Vertically between two exhaust vent terminators on the same wall

60 in

 

 

 

H

Horizontally between two exhaust vent terminators on the same wall

36 in

 

 

 

 

Horizontally and vertically from combustion air inlet of a twin pipe

36 in

I**

system

 

 

 

 

 

 

 

From the gravity combustion air inlet any other equipment

6 ft

J

From any external corner

12 in

K

Horizontally from an opening; operable windows, doors and any non-

12 in (twin pipe installation)

mechanical fresh air openings

48 in (single pipe installation)

 

 

 

 

L

Vertically from a wall, roof slope, or obstruction (venting through a flat

see ABOVE THE ROOF

or pitched roof)

requirements on following page

 

 

 

 

Table 6

* Subject to local codes and anticipated snow level

**Other equipment that operates with a mechanical air inlet may require greater distances, reference manufacturer's instructions NOTE: terminating exhaust vent under a deck is not permitted

10

6 720 608 782

Image 10
Contents Intended for variable flow applications What to do if you smell gasIndex For your safety FCCGWH 2400 ES Specifications Technical data FeaturesAppliance details Unpacking the GWH 2400 ES heater General rules to follow for safe operation To remove combustion cover service onlyAppliance details To remove front cover Dimensions and Minimum installation clearances DimensionsIntroduction Installation instructionsTools required for installation VentingVent Safety System Fittings or Piping Equivalent FeetDescription Minimum distance Installation instructions Venting configuration examples Room sealed installation Twin Pipe System Installation instructions Condensate drain requirementsVenting Flex ProTech Heat Fab Determining installation adjustment ExhaustInstallation instructions Vent connections Combustion air requirements Twin pipeHeater placement and clearances Proper location for installing your heaterMounting installation Gas piping & connections GAS Connections For Natural GAS Water connections Water qualityRecirculation application Recirculation applicationMeasuring gas pressure Electrical connections Electrical power supplyPosition of the fuses in control unit Operation instructions LCD Display functionsPower For your safety read before operating your water heaterTemperature selection Operation Use of optional remote control accessory part no. TSTAT2Reset button Program buttonAnnual maintenance Maintenance and serviceAnnual maintenance table Every year Winterizing for seasonal useDescaling using a pump Adjusting CO2 carbon dioxideMineral scale build-up Returning to Service Measuring CO2 combustion cover must be installedAdjusting CO2 Once Gas Pressure is adequateFinal Readings % 2.8 % 60 ppmProgram values Program Description Factory DefaultComment Control board diagnostics Diagnostic menuIntake Fan speed adjustmentTotal vent length calculation ExampleMaintenance and service To select fan speed Mode Pipe Length1 Fan speedWater is too hot TroubleshootingTroubleshooting Water is not hot enoughLow water flow/pressure Hot water temperature fluctuates at tapNoisy burner/heater during operation Troubleshooting Problem solving Error code diagnosticsProblem solving Display Cause Solution Venting may cause this failureOver-temperature detected by No flame ionization detected with Electrical diagram Electrical diagramSensor resistance charts Back Flow characteristics GWH 2400 ES Functional scheme Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Appliance overview Description Reference Components diagramGroup Item DescriptionInterior components diagram and parts list Group Interior components diagram and parts list Group Interior components diagram and parts list Group Interior components diagram and parts list Group 708 300 Packing Protecting the environmentProtecting the environment ComponentsLimited Warranty Bosch Thermotechnology Corporation

GWH 2400 ES NG, GWH 2400 ES LP specifications

Bosch Appliances has established a reputation for delivering high-quality and innovative home solutions, and the Bosch GWH 2400 ES LP and GWH 2400 ES NG are no exceptions. These high-efficiency water heaters are designed to provide on-demand hot water, ensuring comfort and convenience for your home.

One of the standout features of the Bosch GWH 2400 ES LP (Liquid Propane) and GWH 2400 ES NG (Natural Gas) models is their compact, space-saving design. These tankless water heaters are engineered to fit in smaller spaces, making them an ideal choice for homes with limited installation areas. Despite their compact size, both models provides a powerful performance that meets the hot water needs for multiple fixtures simultaneously, such as showers, faucets, and washing machines.

These water heaters are equipped with advanced technology that enables precise temperature control. The Bosch GWH 2400 ES series utilizes a microprocessor-based control system that allows for consistent water heating, ensuring the water temperature remains stable even during high demand. The modulating gas valve further optimizes energy consumption, adjusting the flame intensity to meet the exact heating needs, thus enhancing efficiency.

In terms of safety, both the GWH 2400 ES LP and NG come with multiple safety features. These include a flame failure safeguard, overheating protection, and a built-in freeze protection system. Such features ensure both peace of mind and the longevity of the unit.

Installation is straightforward with these models, as they can be vented using standard venting materials, saving time and costs. Additionally, the units boast a low NOx emissions rating, making them environmentally friendly choices that help homeowners reduce their carbon footprint.

Maintenance is minimal, thanks to the corrosion-resistant heat exchanger which ensures durability and long service life under normal operating conditions. This factor, combined with Bosch’s renowned commitment to quality, makes these models a reliable investment for any household.

Whether you opt for the GWH 2400 ES LP or the GWH 2400 ES NG, you will experience the benefits of a powerful, efficient, and safe water heating solution tailored to your specific household needs. Bosch has truly combined technology, sustainability, and user comfort in these innovative models, solidifying their place as leaders in the home appliance market.