Bosch Appliances GWH 2400 ES LP, GWH 2400 ES NG manual GAS Connections

Page 18

Installation instructions

INSTALLATION CODES and/or local installation codes.

Warning: DO NOT connect to an unregulated or high pressure propane line or to a high pressure commercial natural gas line.

Warning: The heater must be isolated from the gas supply piping system during any pressure testing of that system at test pressures equal to or more than 0.5 psig. If overpressure has occurred, such as through improper testing of the gas lines or malfunction of the supply system, the gas valve must be checked for safe operation.

GAS CONNECTIONS

BInstall a manual gas shut off valve on the gas supply line within easy reach of the appliance.

BInstall a union when connecting gas supply.

B The minimum internal diameter required for any appliance connector is ¾”.

B Undersized flexible appliance connectors not permitted.

BNational Fuel Gas Code requires that a sediment trap (drip leg) be installed on gas appliances not so equipped. The drip leg must be accessible and not subject to freezing conditions. Install in accordance with the recommendations of the serving gas sup- plier, see Fig. 25.

Minimum

Gas supply

3”

Cap

 

Fig. 25 Gas connection (drip leg)

Once connections are made, check for gas leaks at all joints. Apply some gas leak detection solution to all gas fittings. Bubbles are a sign of a leak. A combustible gas detector may also be used to detect for leaks.

Danger: If you have a leak, shut off the gas. Tighten appropriate fittings to stop leak. Turn the gas on and check again with a gas leak detection solution. Never test for gas leaks using a match or flame.

GAS LINE SIZING

The gas supply piping for a single heater should be sized for a maximum draw of 199,000 BTUH. Measure the length of gas supply line and use the tables in Fig. 27, page 19 or the gas line manufacturer’s sizing tables to determine the pipe diameter necessary to accommodate the 199,000 BTU demand of the heater. If there are more gas appliances on the line, size the gas line according to the total maximum amount of BTU input rating for all appliances.

Note: Undersizing the gas line may result in diminished hot water flow rate and temperature. See chapter 3.12, page 22 for the procedure to confirm gas pressure. Proper gas pressure must be confirmed at time of installation.

Gas piping

Inlet gas particle screen

(included)

Fig. 26

18

6 720 608 782

Image 18
Contents Intended for variable flow applications What to do if you smell gasIndex For your safety FCCFeatures GWH 2400 ES Specifications Technical dataAppliance details Unpacking the GWH 2400 ES heater To remove combustion cover service only General rules to follow for safe operationAppliance details To remove front cover Dimensions and Minimum installation clearances DimensionsIntroduction Installation instructionsTools required for installation VentingVent Safety System Fittings or Piping Equivalent FeetDescription Minimum distance Installation instructions Venting configuration examples Installation instructions Condensate drain requirements Room sealed installation Twin Pipe SystemVenting Flex ProTech Heat Fab Determining installation adjustment ExhaustInstallation instructions Vent connections Combustion air requirements Twin pipeProper location for installing your heater Heater placement and clearancesMounting installation Gas piping & connections GAS Connections For Natural GAS Water connections Water qualityRecirculation application Recirculation applicationMeasuring gas pressure Electrical power supply Electrical connectionsPosition of the fuses in control unit Operation instructions LCD Display functionsFor your safety read before operating your water heater PowerTemperature selection Operation Use of optional remote control accessory part no. TSTAT2Reset button Program buttonAnnual maintenance Maintenance and serviceAnnual maintenance table Every year Winterizing for seasonal useAdjusting CO2 carbon dioxide Descaling using a pumpMineral scale build-up Returning to Service Measuring CO2 combustion cover must be installedAdjusting CO2 Once Gas Pressure is adequateFinal Readings % 2.8 % 60 ppmProgram Description Factory Default Program valuesComment Control board diagnostics Diagnostic menuIntake Fan speed adjustmentTotal vent length calculation ExampleMaintenance and service To select fan speed Mode Pipe Length1 Fan speedWater is too hot TroubleshootingTroubleshooting Water is not hot enoughHot water temperature fluctuates at tap Low water flow/pressureNoisy burner/heater during operation Troubleshooting Problem solving Error code diagnosticsProblem solving Display Cause Solution Venting may cause this failureOver-temperature detected by No flame ionization detected with Electrical diagram Electrical diagramSensor resistance charts Back Flow characteristics GWH 2400 ES Functional scheme Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Appliance overview Description Reference Components diagramGroup Item DescriptionInterior components diagram and parts list Group Interior components diagram and parts list Group Interior components diagram and parts list Group Interior components diagram and parts list Group 708 300 Packing Protecting the environmentProtecting the environment ComponentsLimited Warranty Bosch Thermotechnology Corporation

GWH 2400 ES NG, GWH 2400 ES LP specifications

Bosch Appliances has established a reputation for delivering high-quality and innovative home solutions, and the Bosch GWH 2400 ES LP and GWH 2400 ES NG are no exceptions. These high-efficiency water heaters are designed to provide on-demand hot water, ensuring comfort and convenience for your home.

One of the standout features of the Bosch GWH 2400 ES LP (Liquid Propane) and GWH 2400 ES NG (Natural Gas) models is their compact, space-saving design. These tankless water heaters are engineered to fit in smaller spaces, making them an ideal choice for homes with limited installation areas. Despite their compact size, both models provides a powerful performance that meets the hot water needs for multiple fixtures simultaneously, such as showers, faucets, and washing machines.

These water heaters are equipped with advanced technology that enables precise temperature control. The Bosch GWH 2400 ES series utilizes a microprocessor-based control system that allows for consistent water heating, ensuring the water temperature remains stable even during high demand. The modulating gas valve further optimizes energy consumption, adjusting the flame intensity to meet the exact heating needs, thus enhancing efficiency.

In terms of safety, both the GWH 2400 ES LP and NG come with multiple safety features. These include a flame failure safeguard, overheating protection, and a built-in freeze protection system. Such features ensure both peace of mind and the longevity of the unit.

Installation is straightforward with these models, as they can be vented using standard venting materials, saving time and costs. Additionally, the units boast a low NOx emissions rating, making them environmentally friendly choices that help homeowners reduce their carbon footprint.

Maintenance is minimal, thanks to the corrosion-resistant heat exchanger which ensures durability and long service life under normal operating conditions. This factor, combined with Bosch’s renowned commitment to quality, makes these models a reliable investment for any household.

Whether you opt for the GWH 2400 ES LP or the GWH 2400 ES NG, you will experience the benefits of a powerful, efficient, and safe water heating solution tailored to your specific household needs. Bosch has truly combined technology, sustainability, and user comfort in these innovative models, solidifying their place as leaders in the home appliance market.