Bosch Appliances GWH 2400 ES NG, GWH 2400 ES LP manual Recirculation application

Page 21

Installation instructions

Connecting the pressure relief valve (PRV)

A listed pressure relief valve supplied with the heater must be installed at the time of installation. No valve is to be placed between the PRV and the heater. No reducing coupling or other restriction may be installed in the discharge line. The discharge line must be a minimum of 4” above a drain and installed such that it allows complete drainage of both the PRV and the line. The discharge line must be placed where it will not cause any damage.

The location of the PRV must be readily accessible for servicing or replacement, and be mounted as close to the water heater as possible. See Fig. 29. To install the PRV, a suitable fitting connected to an extension on a “T” fitting can be sweated to the hot water line.

Support all piping.

Fig. 29 Plumbing Connections (with shutoff valves) and Pressure Relief Valve

1Water filter

3.11 Recirculation application

The following drawing is provided to outline one possible recirculation design using the water heater in conjunction with an Ariston mini tank water heater. Recirculation directly through the tankless water heater not allowed. This schematic is for illustration only and must not be used for actual installation without appropriate engineering and technical advice from a properly licensed professional in the locality where the installation is made.

GWH 2400 ES

Ariston Minitank

Fig. 30 Recirculation application

1Full port isolation valve

2 Circulator (pump)

3 Check valve

4PRV

5Expansion tank

The use of a small electric mini-tank water heater (4-6 gallon size) should be used for this application and designed so the pump will circulate the water through the mini-tank and the building's hot water return loop only. Timed or thermostatically controlled operation of the pump is commonly done. Contact Bosch Water Heating if further information is needed.

6 720 608 782

21

Image 21
Contents What to do if you smell gas Intended for variable flow applicationsIndex FCC For your safetyFeatures GWH 2400 ES Specifications Technical dataAppliance details Unpacking the GWH 2400 ES heater To remove combustion cover service only General rules to follow for safe operationAppliance details To remove front cover Dimensions Dimensions and Minimum installation clearancesTools required for installation Installation instructionsIntroduction VentingFittings or Piping Equivalent Feet Vent Safety SystemDescription Minimum distance Installation instructions Venting configuration examples Installation instructions Condensate drain requirements Room sealed installation Twin Pipe SystemVenting Flex ProTech Heat Fab Exhaust Determining installation adjustmentInstallation instructions Vent connections Twin pipe Combustion air requirementsProper location for installing your heater Heater placement and clearancesMounting installation Gas piping & connections GAS Connections For Natural GAS Water quality Water connectionsRecirculation application Recirculation applicationMeasuring gas pressure Electrical power supply Electrical connectionsPosition of the fuses in control unit LCD Display functions Operation instructionsFor your safety read before operating your water heater PowerTemperature selection Reset button Use of optional remote control accessory part no. TSTAT2Operation Program buttonAnnual maintenance table Every year Maintenance and serviceAnnual maintenance Winterizing for seasonal useAdjusting CO2 carbon dioxide Descaling using a pumpMineral scale build-up Adjusting CO2 Measuring CO2 combustion cover must be installedReturning to Service Once Gas Pressure is adequate% 2.8 % 60 ppm Final ReadingsProgram Description Factory Default Program valuesComment Diagnostic menu Control board diagnosticsTotal vent length calculation Fan speed adjustmentIntake ExampleMode Pipe Length1 Fan speed Maintenance and service To select fan speedTroubleshooting TroubleshootingWater is too hot Water is not hot enoughHot water temperature fluctuates at tap Low water flow/pressureNoisy burner/heater during operation Troubleshooting Error code diagnostics Problem solvingVenting may cause this failure Problem solving Display Cause SolutionOver-temperature detected by No flame ionization detected with Electrical diagram Electrical diagramSensor resistance charts Back Flow characteristics Functional scheme GWH 2400 ES Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Appliance overview Group Components diagramDescription Reference Item DescriptionInterior components diagram and parts list Group Interior components diagram and parts list Group Interior components diagram and parts list Group Interior components diagram and parts list Group 708 300 Protecting the environment Protecting the environmentPacking ComponentsLimited Warranty Bosch Thermotechnology Corporation

GWH 2400 ES NG, GWH 2400 ES LP specifications

Bosch Appliances has established a reputation for delivering high-quality and innovative home solutions, and the Bosch GWH 2400 ES LP and GWH 2400 ES NG are no exceptions. These high-efficiency water heaters are designed to provide on-demand hot water, ensuring comfort and convenience for your home.

One of the standout features of the Bosch GWH 2400 ES LP (Liquid Propane) and GWH 2400 ES NG (Natural Gas) models is their compact, space-saving design. These tankless water heaters are engineered to fit in smaller spaces, making them an ideal choice for homes with limited installation areas. Despite their compact size, both models provides a powerful performance that meets the hot water needs for multiple fixtures simultaneously, such as showers, faucets, and washing machines.

These water heaters are equipped with advanced technology that enables precise temperature control. The Bosch GWH 2400 ES series utilizes a microprocessor-based control system that allows for consistent water heating, ensuring the water temperature remains stable even during high demand. The modulating gas valve further optimizes energy consumption, adjusting the flame intensity to meet the exact heating needs, thus enhancing efficiency.

In terms of safety, both the GWH 2400 ES LP and NG come with multiple safety features. These include a flame failure safeguard, overheating protection, and a built-in freeze protection system. Such features ensure both peace of mind and the longevity of the unit.

Installation is straightforward with these models, as they can be vented using standard venting materials, saving time and costs. Additionally, the units boast a low NOx emissions rating, making them environmentally friendly choices that help homeowners reduce their carbon footprint.

Maintenance is minimal, thanks to the corrosion-resistant heat exchanger which ensures durability and long service life under normal operating conditions. This factor, combined with Bosch’s renowned commitment to quality, makes these models a reliable investment for any household.

Whether you opt for the GWH 2400 ES LP or the GWH 2400 ES NG, you will experience the benefits of a powerful, efficient, and safe water heating solution tailored to your specific household needs. Bosch has truly combined technology, sustainability, and user comfort in these innovative models, solidifying their place as leaders in the home appliance market.