Applications manual

 

 

2.10 Bosch GWH 260 PN

Features:

Standing pilot ignition

78% thermal efficiency

Mounts on wall for easy installation

Venting: 4" double wall B-vent — natural draft

Modulating gas valve — constant temperature at varying flow rates Model GWH 260 PN N for natural gas (NG) supply

Model GWH 260 PN L for liquid propane (LP) supply 15-year warranty

GWH 260 PN Installation Clearances

Top (A)

12"

 

 

Front (B)

4"

Back

0"

 

 

Sides

4"

 

 

Floor (C)

12"

 

 

GWH 260 PN Technical Specifications

Gas input

Natural Gas: 30,735 - 74,900 BTU

 

 

 

LP Gas: 30,735 - 74,900 BTU

 

 

Minimum flow to activate

0.6 gallons per minute (gpm)

Flow rates

45˚F rise @ 2.6 gpm

 

55˚F rise @ 2.1 gpm

 

65˚F rise @ 1.7 gpm

 

77˚F rise @ 1.5 gpm

 

90˚F rise @ 1.3 gpm

 

 

Thermal Efficiency

NG: 78% LP: 78%

Dimensions

28.8" h x 12.2" w x 8.5" d

Weight

25 lbs.

Modulating gas valve

yes

Ignition

Standing pilot

 

GWH 260 PN Installation Specifications

Gas connection

¾" Male NPT

 

 

Water connections

¾" Male NPT

NG gas pressure

Minimum: 7" W.C.

 

Maximum: 14" W.C.

 

 

LP gas pressure

Minimum: 11" W.C.

 

Maximum: 14" W.C.

 

 

Water pressure

Minimum: 30 PSI

(Static)

Minimum well pressure: 40PSI

 

Maximum: 150 PSI

 

 

Electrical supply

120VAC - plugs in

Venting

4" double wall B-vent - natural

 

draft

 

 

LIS TED VE NT C AP

MINIMUM 6

FE ET (1.8M)

LIS TED G AS VE NT

E S TAB LIS H A ONE

F OOT R IS E B E F OR E

ANY E LB OW S

Fig. 4 Venting configuration

Installation guidelines:

Venting:

4" minimum diameter — do not reduce vent size. Refer to installation manual for vent material options

Do not combination vent with any power vented appliances.

Establish a one-foot rise before any elbows

Minimum vent height - 6 feet.

Horizontal sections must slope upwards at least ¼" for every foot of the horizontal length and be properly supported.

Gas piping:

Heater will not function properly without adequate supply gas pressure.

Any appliance connector should be ¾" minimum diameter

Plumbing:

Install the included pressure relief valve and pipe to suitable drain.

Minimum piping diameter is ¾".

Do not solder directly to the bottom of the unit. Use full port ball valves for isolation valves.

Application manual 11.2007

Bosch Water Heating

Image 14
Contents Applications manual Table of Contents Introduction Definitions Sizing by ChartSizing tankless water heaters Rule of thumb sizingGas Appliance Sizing Chart Applications manual GWH 715 ES Installation Clearances FeaturesGWH 715 ES Installation Specifications Installation guidelinesGWH C 800 ES Technical Specifications GWH C 800 ES Installation SpecificationsGWH C 800 ES Installation Clearances Description Min Distances Outdoor Installation for GWH 715 ESGWH C 800 ES GWH 345 ESR Technical Specifications GWH 345 ESR Installation SpecificationsGWH 450 ESR Installation Clearances GWH 450 ESR Installation Specifications GWH 450 ESR Technical SpecificationsGWH 425 EF Technical Specifications GWH 425 EF Installation SpecificationsGWH 425 EF Installation Clearances GWH 425 HN Technical Specifications GWH 425 HN Installation SpecificationsGWH 425 HN Installation Clearances Establish a one-foot rise before any elbowsGWH 425 PN Technical Specifications GWH 425 PN Installation SpecificationsGWH 425 PN Installation Clearances GWH 260 PN Technical Specifications GWH 260 PN Installation ClearancesGWH 260 PN Installation Specifications Electrical requirements Maximum flow rate at given temperature riseTechnical Specifications Powerstream Pro RP1P, RP2P, RP3P, RP7P, RP9P,RP12PT Ariston Pro GL2.5Ti, GL4Ti, GL8Ti Introduction Point-of-use applicationsPotable water Relief valve Temperature and pressureService valve SinkService valve Sink Flow direction Temperature and pressure relief valve Sink Service valves Low flow Flow direction ShowerPowerstream Pro whole house applications Service Sink valvesPowerstream Pro RP17PT or RP27PT Standard tub fixtureHotCold Symbols Bosch ProTankless gas water heaterHot Cold Parallel unit applications Pressure relief valves Bosch GWH 715 ES Bosch GWH C 800 ESCascading unit applications GWH 715 ES and GWH C 800 ES cascadingPressure Bosch GWH 345 ESR Bosch GWH 450 ESR Single unit tank loading application plumbing diagramCold water Feed DHW Single Unit Tank Loading Electrical Diagram ESR control BoardFeed Radiant space heating and DHW plumbing diagramCold water External storage tankRadiant Space Heating and DHW Electrical Diagram Radiant space heating and DHW electrical diagramBosch GWH 345 ESR, Bosch GWH 450 ESR Fan coil space heating and DHW plumbing diagramFan Coil Cold water Fan Coil Space Heating and DHW Electrical Diagram Fan Coil space heating and DHW electrical diagramDrawing # BB OL RevA 10/07 Baseboard Space Heating and DHW Electrical Diagram Drawing # Bbaol RevA 10/07 Pkps Insulate piping Cold water feed Terminal box Baseboard Radiant Panel Back Flow preventerDrawing # EID Bbol CN revA 10/07 Descaling procedure Circulating pump Flow direction Filter Service valves Applications manual Applications manual Applications manual Applications manual BBT North America Corporation