Bosch Appliances GWH 260 PN/HN2 manual Features, GWH 715 ES Technical Specifications

Page 6

6

2.2 Bosch GWH 715 ES

Features:

Electronic ignition and built in power vent 82% thermal efficiency

Vents vertically or horizontally with 3" or 4" stainless steel (AL29- 4C)

Direct vent room-sealed combustion

Computerized temperature control — ensures temperature stability Model GWH 715 ES N for natural gas (NG) supply

Model GWH 715 ES L for liquid propane (LP) supply 15-year warranty

Qualifies for $300 tax credit

GWH 715 ES Technical Specifications

Gas input

Natural Gas: 19,900 - 199,000 BTU

 

 

 

 

LP Gas: 19,900 - 199,000 BTU

 

 

 

Minimum flow to activate

0.65 gallons per minute (gpm)

Flow rates

45˚F rise @ 7.2 gpm

 

55˚F rise @ 5.9 gpm

 

65˚F rise @ 5.0 gpm

 

77˚F rise @ 4.2 gpm

 

90˚F rise @ 3.6 gpm

 

 

 

Thermal Efficiency

NG: 82% LP: 82%

Dimensions

30½" h x 17⅞" w x 11¼" d

Weight

67 lbs.

Modulating gas valve

yes

Ignition

Electronic

Accessories

Outdoor kit (PTOK)

 

Wireless Remote (TSTAT2)

 

Tankless Link Cascading Kit (TLINK)

 

Freeze Prevention Kit (8700400022)

 

Water Filter Kit (8703305356)

 

 

 

GWH 715 ES Installation Specifications

 

Gas connection

¾" Male NPT

 

 

 

Water connections

¾" Male NPT

 

NG gas pressure

Minimum: 4" W.C.

 

Maximum: 14" W.C.

 

 

 

LP gas pressure

Minimum: 9" W.C.

 

Maximum: 14" W.C.

 

 

 

Water pressure

Minimum: 30 PSI

(Static)

Minimum well pressure: 40 PSI

 

Maximum: 150 PSI

 

Electrical supply

120VAC - plugs in

 

Venting

3" or 4" stainless steel (AL29-4C)

 

direct vent

 

room-sealed combustion

 

 

 

Applications manual

GWH 715 ES Installation Clearances

Top (A)

12"

 

 

Front (B)

1"

Back

0"

 

 

Sides

1"

 

 

Floor (C)

12"

 

 

3ft minimum distance

3ft minimum distance

Fig. 1 Venting configurations

Installation guidelines:

Venting:

Must be 3" or 4" AL29-4C sealed stainless steel vent pipe. Slope horizontal runs up to termination ¼" per foot. The last horizontal section of exhaust vent pipe between last elbow and termination must slope down to the termination ¼" per foot. Do not combination vent with any other appliance.

Install condensate drain where applicable. See manual for vent terminator clearances.

Gas piping:

Heater will not function properly without adequate supply gas pressure.

Any appliance connector should be ¾" minimum diameter

Plumbing:

Install the included pressure relief valve and pipe to suitable drain.

Minimum piping diameter is ¾".

Do not solder directly to the bottom of the unit. Use unions to facilitate easy future maintenance. Use full port ball valves for isolation valves.

Partially fill condensate drain tube loop (where applicable) with water prior to start up.

Application manual 11.2007

Bosch Water Heating

Image 6
Contents Applications manual Table of Contents Introduction Definitions Sizing by ChartSizing tankless water heaters Rule of thumb sizingGas Appliance Sizing Chart Applications manual GWH 715 ES Installation Clearances FeaturesGWH 715 ES Installation Specifications Installation guidelinesGWH C 800 ES Installation Specifications GWH C 800 ES Installation ClearancesGWH C 800 ES Technical Specifications Outdoor Installation for GWH 715 ES GWH C 800 ESDescription Min Distances GWH 345 ESR Installation Specifications GWH 450 ESR Installation ClearancesGWH 345 ESR Technical Specifications GWH 450 ESR Installation Specifications GWH 450 ESR Technical SpecificationsGWH 425 EF Installation Specifications GWH 425 EF Installation ClearancesGWH 425 EF Technical Specifications GWH 425 HN Technical Specifications GWH 425 HN Installation SpecificationsGWH 425 HN Installation Clearances Establish a one-foot rise before any elbowsGWH 425 PN Installation Specifications GWH 425 PN Installation ClearancesGWH 425 PN Technical Specifications GWH 260 PN Installation Clearances GWH 260 PN Installation SpecificationsGWH 260 PN Technical Specifications Maximum flow rate at given temperature rise Technical SpecificationsElectrical requirements Powerstream Pro RP1P, RP2P, RP3P, RP7P, RP9P,RP12PT Ariston Pro GL2.5Ti, GL4Ti, GL8Ti Point-of-use applications Potable waterIntroduction Relief valve Temperature and pressureService valve SinkService valve Sink Flow direction Temperature and pressure relief valve Sink Service valves Low flow Flow direction ShowerPowerstream Pro whole house applications Service Sink valvesPowerstream Pro RP17PT or RP27PT Standard tub fixtureHotCold Symbols Bosch ProTankless gas water heaterHot Cold Parallel unit applications Pressure relief valves Bosch GWH 715 ES Bosch GWH C 800 ESCascading unit applications GWH 715 ES and GWH C 800 ES cascadingPressure Single unit tank loading application plumbing diagram Cold water Feed DHWBosch GWH 345 ESR Bosch GWH 450 ESR Single Unit Tank Loading Electrical Diagram ESR control BoardFeed Radiant space heating and DHW plumbing diagramCold water External storage tankRadiant Space Heating and DHW Electrical Diagram Radiant space heating and DHW electrical diagramFan coil space heating and DHW plumbing diagram Fan Coil Cold waterBosch GWH 345 ESR, Bosch GWH 450 ESR Fan Coil Space Heating and DHW Electrical Diagram Fan Coil space heating and DHW electrical diagramDrawing # BB OL RevA 10/07 Baseboard Space Heating and DHW Electrical Diagram Drawing # Bbaol RevA 10/07 Pkps Insulate piping Cold water feed Terminal box Baseboard Radiant Panel Back Flow preventerDrawing # EID Bbol CN revA 10/07 Descaling procedure Circulating pump Flow direction Filter Service valves Applications manual Applications manual Applications manual Applications manual BBT North America Corporation