Bosch Appliances GWH 260 PN/HN2, GWH 425 PN/HN4GWH 4254 manual Cascading unit applications

Page 28

2 8

Applications manual

 

 

4.2 Cascading unit applications

A cascading application should be considered if the potential hot water demand exceeds the capacity of one GWH 715 ES or

GWH C 800 ES. The cascading set up supports variable flow inputs and is designed for large homes and commercial applications.

4.2.1 GWH 715 ES and GWH C 800 ES cascading

Cascading allows up to two appliances to be connected in parallel. One of the appliances will serve as the controlling Master appliance and will attempt to meet the hot water demand. If the hot water demand is beyond the capacity of the Master appliance, a signal is sent to the Slave appliance to begin operation.

hot

 

 

 

tankless link

 

 

cold

 

hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cold

hot

outlet

 

 

 

 

 

inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ariston Pro GL8Ti recommended

Bosch GWH 715 ES or

Bosch GWH C 800 ES

• The plumbing must be connected in the reverse

 

return method with a minimum number of elbows

 

to aid in balancing pressures between the two

 

appliances.

 

 

 

• If a domestic recirculation system is desired,

 

recirculate the water through the Ariston ProTi

 

water heater as seen in chapter 3.4.

cold

• Locate appliances close together for

 

improved performance.

 

 

 

• Follow industry plumbing practices when installing

 

multiple appliances

 

 

 

• Minimum pipe diameter: ¾"

 

 

 

• Minimum water pressure: 50 psi

 

 

 

• Maximum distance between appliances: 36"

 

• Insulate pipes to prevent heat loss.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbols

 

 

 

 

 

 

 

Flow direction

 

 

 

 

 

 

 

 

 

 

 

Water

Pressure

 

 

 

 

 

hammer

 

 

relief

 

 

 

 

 

 

 

 

 

 

arrestor

 

 

valve

 

 

 

 

 

 

 

 

 

 

Service

Tankless

 

 

 

 

 

valves

link

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: This drawing is conceptual in nature and does not address all design, installation or safety considerations.

Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers.

It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale.

Drawing # CA1

CN revA 10/07

Application manual 11.2007

Bosch Water Heating

Image 28
Contents Applications manual Table of Contents Introduction Sizing by Chart Sizing tankless water heatersDefinitions Rule of thumb sizingGas Appliance Sizing Chart Features GWH 715 ES Installation SpecificationsApplications manual GWH 715 ES Installation Clearances Installation guidelinesGWH C 800 ES Installation Clearances GWH C 800 ES Installation SpecificationsGWH C 800 ES Technical Specifications GWH C 800 ES Outdoor Installation for GWH 715 ESDescription Min Distances GWH 450 ESR Installation Clearances GWH 345 ESR Installation SpecificationsGWH 345 ESR Technical Specifications GWH 450 ESR Installation Specifications GWH 450 ESR Technical SpecificationsGWH 425 EF Installation Clearances GWH 425 EF Installation SpecificationsGWH 425 EF Technical Specifications GWH 425 HN Installation Specifications GWH 425 HN Installation ClearancesGWH 425 HN Technical Specifications Establish a one-foot rise before any elbowsGWH 425 PN Installation Clearances GWH 425 PN Installation SpecificationsGWH 425 PN Technical Specifications GWH 260 PN Installation Specifications GWH 260 PN Installation ClearancesGWH 260 PN Technical Specifications Technical Specifications Maximum flow rate at given temperature riseElectrical requirements Powerstream Pro RP1P, RP2P, RP3P, RP7P, RP9P,RP12PT Ariston Pro GL2.5Ti, GL4Ti, GL8Ti Potable water Point-of-use applicationsIntroduction Temperature and pressure Service valveRelief valve SinkService valve Sink Flow direction Temperature and pressure relief valve Sink Service valves Low flow Flow direction ShowerService Sink valves Powerstream Pro RP17PT or RP27PTPowerstream Pro whole house applications Standard tub fixtureHotCold Symbols Bosch ProTankless gas water heater Hot Cold Parallel unit applications Pressure relief valves Bosch GWH 715 ES Bosch GWH C 800 ESCascading unit applications GWH 715 ES and GWH C 800 ES cascadingPressure Cold water Feed DHW Single unit tank loading application plumbing diagramBosch GWH 345 ESR Bosch GWH 450 ESR Single Unit Tank Loading Electrical Diagram ESR control BoardRadiant space heating and DHW plumbing diagram Cold waterFeed External storage tankRadiant Space Heating and DHW Electrical Diagram Radiant space heating and DHW electrical diagramFan Coil Cold water Fan coil space heating and DHW plumbing diagramBosch GWH 345 ESR, Bosch GWH 450 ESR Fan Coil Space Heating and DHW Electrical Diagram Fan Coil space heating and DHW electrical diagramDrawing # BB OL RevA 10/07 Baseboard Space Heating and DHW Electrical Diagram Drawing # Bbaol RevA 10/07 Pkps Insulate piping Cold water feed Terminal box Baseboard Radiant Panel Back Flow preventerDrawing # EID Bbol CN revA 10/07 Descaling procedure Circulating pump Flow direction Filter Service valves Applications manual Applications manual Applications manual Applications manual BBT North America Corporation