Bradford-White Corp UTW465S60FR*N, UTW450S60FR*N, U2TW50T*FRN, U2TW65T*FRN Specifications

Page 8

Specifications

 

Power Supply

Dedicated 115VAC, 60 Hz, 15A.

 

 

 

 

 

 

Gas Supply Pipe

Minimum 1/2” NPT (schedule 40 black iron pipe recommended).

 

 

 

 

 

 

Approved Gas Type

Natural Gas.

 

 

 

 

 

 

Gas Pressure

6.0” W.C. minimum, 11.0” W.C. maximum.

 

 

 

 

 

 

Venting System

Power vent through the wall or vertical through the roof.

 

 

 

 

 

 

Approved Vent Materials

PVC, CPVC or ABS.

 

 

 

 

 

 

Minimum clearance for

18” from top, 24” from front, 4” sides and rear.

 

 

Servicing

 

 

 

 

 

 

 

 

 

Water Supply Pressure

150 PSI maximum allowable working pressure. Check local codes for

 

 

supply pressure.

 

 

 

 

 

 

 

 

 

TCO Limit

Residential 118oF (87oC), Commercial 199oF (93oC).

 

 

 

 

 

 

Residential Temperature

60oF (16oC) to 160oF (71oC) (approximate temperatures).

 

 

Set Point Range

 

 

 

Commercial Tempera-

80oF (27oC) to 180oF (82oC) (approximate temperatures).

 

 

ture Set Point Range

 

 

 

 

 

 

 

 

 

Blower Temperature

Normally closed, opens @ 165oF (74oC), auto reset @130oF (54oC)

 

 

Switch

 

 

 

 

 

 

 

 

 

 

UTW1 Models:

 

 

 

Normally open, closes on vacuum increase @ -0.68, opens on vacuum

 

 

Pressure Switch

decrease @ -0.65

 

 

U2TW Models:

 

 

 

 

 

 

Normally open, closes on vacuum increase @ -1.28, opens on vacuum

 

 

 

decrease @-1.25

 

 

 

 

 

 

 

UTW1 Models:

 

 

Blower

115VAC, 60Hz, 3.1 amps, 3000 RPM, 42 CFM @ 1.5” W.C.

 

 

U2TW Models:a,

 

 

 

 

 

 

115VAC, 60Hz, 3.1 amps, 3000 RPM, 68 CFM @ 0.4” W.C.

 

 

 

 

 

Page 8

8

Image 8
Contents Service Manual Table of Contents Page Page Introduction Bradford White ECO-DEFENDER Safety SystemIntroduction How to Use this Manual How to Use this ManualHow the Safety System Works Tools Required for Service Tools RequiredSpecifications Vent Tables Gallon-40,000 BTU/hr Gallon-42,000 BTU/hrGallon-60,000 BTU/hr Ignition State Timing Wiring DiagramControl Timings Normal Heating Sequence Power Up SequenceSequence of Operation Normal Heating Sequence cont’d Abnormal OperationAbnormal Operation cont’d Sequence of Operation Sequence of Operation Troubleshooting Probable Cause Service ProcedureLED Status Control Status Probable Cause Service Procedure Troubleshooting Burner Inspection Burner MaintenanceBurner Cleaning Procedure Burner Cleaning Procedure cont’d Pilot Maintenance Pilot Inspection, Testing and ReplacementPilot Inspection, Testing and Replacement cont’d Page Pressure Switch Testing Pressure Switch TestingPressure Switch Testing cont’d Pressure Switch Replacement Pressure Switch ReplacementBlower Testing Blower TestingBlower Testing Blower Removal Blower ReplacementBlower Installation Blower Temperature Switch Testing Blower Temperature Switch TestingBlower Installation cont’d Common causes for high Exhaust temperature Blower Temperature Switch Testing cont’dSwitch Setting Blower Temperature Switch Replacement Blower Temperature Switch ReplacementThermal Well Testing Thermal Well TestingDetermine Water Temperature Inside Tank Determine Tank TemperatureThermal Well Testing cont’d Gas Control & Thermal Well Removal From Water Heater Component DisassemblySensor Resistance at Various Temperatures Gas Control Removal From Thermal Well Gas Control RemovalGas Control & Thermal Well Removal From Water Heater cont’d Gas Control Removal From Thermal Well cont’d Gas Control AssemblyGas Control Assembly to the Thermal Well Gas Control Assembly to the Thermal Well cont’d VAC Circuit Trace Flammable Vapor Sensor TestingFlammable Vapor Sensor Testing VAC Circuit Trace Safety Circuit Voltage Trace Safety Circuit Voltage TraceRemove the Blower to Gain Access to the Flue Baffle Blower RemovalDip Tube Inspection Remove the Blower to Gain Access to the Flue Baffle cont’dDip Tube Inspection and Replacement Anode Inspection and Replacement Anode InspectionInner Door Removal Procedure Inner Door RemovalInner Door Gasket Replacement Procedure Inner Door Gasket ReplacementInner Door Removal Procedure cont’d Inner Door Installation Inner Door Installation with GasketArrestor Cleaning ScreenLok Flame Arrestor Cleaning ProcedureCommon Terms Common TermsParts List Part Name and DescriptionParts@bradfordwhite.com Techserv@bradfordwhite.com

U1TW40S*FRN, U2TW65T*FRN, UTW450S60FR*N, U1TW60T*FRN, UTW465S60FR*N specifications

Bradford-White Corp has long been a reputable manufacturer in the water heating industry, known for delivering high-quality and reliable products. Among their diverse range of water heaters, the U1TW40S*FRN, U1TW50S*FRN, U1TW60T*FRN, UTW465S60FR*N, and UTW450S60FR*N models stand out for their advanced features and technologies designed to meet varying hot water demands.

The U1TW series, including the U1TW40S*FRN, U1TW50S*FRN, and U1TW60T*FRN models, are well-suited for residential applications. Each model provides different capacities, with the numbers referring to the gallon capacities. The U1TW40S*FRN offers 40 gallons, the U1TW50S*FRN 50 gallons, and the U1TW60T*FRN 60 gallons, making them ideal for households varying in size and hot water requirements.

These models are equipped with Bradford-White's advanced Vitraglas® tank lining, a unique feature that provides superior protection against corrosion and extends the unit's lifespan by ensuring the inner tank remains free from damage. Additionally, their efficient heating elements and optimal insulation minimize heat loss, enhancing energy savings.

The UTW series, specifically the UTW465S60FR*N and UTW450S60FR*N, feature innovative technologies such as a durable stainless steel construction that offers robust performance while resisting the harmful effects of rust and degradation. This is particularly beneficial in areas with hard water, where mineral buildup can be problematic.

Each unit incorporates Bradford-White's signature HydroBurner® technology, which enhances combustion efficiency, ensuring that the water is heated quickly and consistently. This technology also helps in reducing greenhouse gas emissions, addressing environmental concerns while maintaining optimal performance.

In terms of ease of use, all models come with user-friendly controls that allow for easy temperature adjustments and monitoring, ensuring that users can customize their hot water needs conveniently. Additionally, features such as intuitive diagnostics enable quick troubleshooting, reducing downtime and maintenance efforts.

In conclusion, Bradford-White’s U1TW and UTW series water heaters are engineered to offer efficiency, durability, and user-friendly operation. With their advanced technology, excellent insulation, and robust construction, these models are a solid choice for anyone looking to invest in reliable hot water solutions for their home. Whether for a busy family or more modest hot water needs, these units provide peace of mind and consistent performance.