Bradford-White Corp M2TW50T*F, M4TW60T*F, M4TW50T*F, M2TW65T*F, M1TW40S*F Steady state operation

Page 11

Sequence of Operation

Steady state operation.

7

8

During Steady State Operation the Control Monitors:

Thermostat temperature sensor- When set point temperature is satisfied, gas valve is shut down and blower will post purge for 15 seconds. Control LED flashes a short flash once every 4 seconds (idle) status code.

Pressure switch / Blower temperature switch- If either switch opens, pilot valve and main valve is shut

down. The blower continues to runs for 30 seconds attempting to close the circuit. The control LED Flashes 3 times with 3 second pause.

Flame Sensor- If flame is lost, pilot & main valve are shut down, blower runs for 15 seconds. Control attempts to re-light pilot 4 times. If unsuccessful, Blower is shut down and control proceeds to 5 minute lockout. Control re-attempts to light pilot starting at normal heating sequence #2.

Thermostat satisfies (Control LED flashing once every 4 seconds).

9Burner off.

10Blower post purge (15 seconds).

1.Flammable Vapor Sensor Fault:

a)If the resistance is greater than 70,000 Ohms - the gas control immediately turns off all outputs. Control waits

and monitors resistance for 30 seconds. If the resistance is greater than 65,000 ohms after 30 seconds, the gas control proceeds to verify resistive delay for 2 minutes and flashes 7 times then once with a three second pause. This process is repeated 5 times until the control either returns to normal operation or proceeds to flammable vapor lockout.

b)If the resistance is below 3000 ohms - The gas control immediately turns off all outputs and proceeds to flash 8 times then once with three second pause. The error self clears if the resistance returns to normal range for at least 15 seconds.

2. Temperature Sensor Fault:

a)Temperature sensor detected open circuit - The gas control Immediately turns off all outputs and proceeds to flash 8 times then three times with three second pause. The error self clears if the fault clears for at least 15 seconds.

b)Thermal well sensors not reading the same temperature within ±5.5 °F - The gas control Immediately turns off all outputs and proceeds to flash 8 times then three times with three second pause. The error self clears if the fault clears for at least 15 seconds.

c)Water temperature in excess of TCO (Temperature Cut Off) limit - The gas control immediately turns off pilot main valve and proceeds to flash 4 times with 3 second pause. Blower continues to run until gas control is reset. To reset control, rotate knob of temperature control to the minimum setting for at least 6 seconds before returning to desired temperature setting.

Page1111

11

Image 11
Contents Service Manual Through-The-Wall Gas Water Heaters For Your Safety Introduction How to Use This Manual Specifications Vent Tables Vent Tables Control Timings Sequence of Operation Steady state operation Pressure Switch/Blower Temperature Fault Troubleshooting Eight-one flash, three Vapor Sensor Burner Inspection and Air Shutter Adjustment Burner Cleaning Pilot Inspection, Testing and Replacement Pressure Switch Testing Pressure Switch Replacement Pressure tap Blower TestingRemove exhaust Blower Temperature Switch Testing Blower Temperature Switch Replacement Thermal Well Testing Gas Control TestingDetermine Water Temperature Inside Tank Gas Control Removal From Thermal Well Gas Control & Thermal Well Removal From Water HeaterGas Control Assembly to Thermal Well Flammable Vapor Device Testing Red wire leading to blower temperature N Safety Circuit Voltage TraceVAC Circuit Trace Dip Tube Inspection and Replacement Anode Inspection and Replacement Flue baffle Remove blower to gain access to system from exhaustInner Door Gasket Replacement Procedure Inner Door Removal ProcedureInstallation of Inner Door With Gasket Replace outer jacket burner access door ScreenLok Flame Arrestor Cleaning Glossary of Terms Parts List Parts@bradfordwhite.com Techserv@bradfordwhite.com

M4TW40T*F, M1TW50S*F, M2TW50T*F, M4TW50T*F, M4TW60T*F specifications

Bradford-White Corporation is a leading manufacturer of water heating and storage solutions, known for its commitment to quality and innovation. Among its impressive product lineup, the M2TW65T*F, TW465S65F, TW450S65F, M1TW40S*F, and M1TW60T*F models stand out for their reliability and advanced technology suitable for both residential and commercial applications.

The M2TW65T*F model is distinguished by its high efficiency and performance. It features a 65-gallon capacity, which is ideal for households that require a significant amount of hot water. This model is equipped with an innovative electronic ignition system that enhances energy efficiency while providing reliable hot water on demand. Additionally, it includes advanced insulation technology that minimizes heat loss, ensuring that water remains hot for extended periods.

The TW465S65F and TW450S65F are other exemplary models in the Bradford-White lineup, boasting impressive storage capabilities. Both models offer a combination of a 65-gallon tank and powerful burner systems that significantly reduce recovery time, meaning users can enjoy hot water faster. These models are designed with a user-friendly control panel, making adjustments and monitoring water temperature straightforward. Their robust construction ensures durability and longevity, making them a smart investment.

For smaller households or spaces, the M1TW40S*F and M1TW60T*F models provide excellent options without compromising performance. The M1TW40S*F, with a 40-gallon capacity, is specifically designed for efficiency in limited spaces, while the M1TW60T*F offers extra capacity for larger demands. Both models utilize Bradford-White's state-of-the-art gas burner technology, promoting energy conservation while delivering consistent hot water.

All models are built with a high-quality glass-lined tank to protect against corrosion, further enhancing their lifespan. The incorporation of Bradford-White's exclusive EverKlean technology in their tank designs minimizes sediment buildup, ensuring clean and efficient operation over time.

In addition to their standout performance and efficiency, Bradford-White products prioritize safety. Built-in safety features, such as the temperature and pressure relief valve and advanced venting designs, provide peace of mind for users. These models not only meet but often exceed industry standards for safety and efficiency.

Bradford-White's commitment to innovation and quality is reflected in the M2TW65T*F, TW465S65F, TW450S65F, M1TW40S*F, and M1TW60T*F models, making them excellent choices for anyone in need of reliable hot water solutions. With their advanced technologies, durability, and energy efficiency, these water heaters are ideal for diverse applications in modern homes and businesses.