Bradford-White Corp M1TW40S*F, M4TW60T*F, M2TW50T*F Gas Control Testing, Thermal Well Testing

Page 24

TTW SERVICE PROCEDURE VI

Gas Control/Thermal Well Testing and

Replacement

Gas Control Testing

See pages 29 & 30 for gas control voltage testing.

Thermal Well Testing

If Control has gone into TCO lockout due to

excessive tank temperature (four flash, 3 second pause) reset control by rotating knob of temperature control to the minimum setting for at least 6 seconds before returning to desired temperature setting.

Disconnect thermal

well wire harness

Observe heater operation. If control

continues to lockout due to excessive tank temperature, proceed to thermal well testing to determine cause.

Thermal well testing

Position gas control power switch to the “OFF” position and disconnect thermal well harness from gas control.

Using a multi-meter set to the Ohms setting, determine the resistance of thermal well sensor (see caution photos 19 & 20)

19

20

CAUTION

DO NOT use standard multimeter probes for this test. Doing so will damage connector. Use special pin type electronic probes or small diameter wire pins inserted into connector.

Using a multi-meter set to the ohms setting, insert one meter probe (see caution) into center wire position of thermal well connector, insert the second probe (see caution) into either of the outside wire positions (see photo 19).

Alternate the probe on the outside position to the opposite outside wire position (see photo 20).

Once the thermal well resistance values are known, the water

 

 

temperature must also be known to determine if the resistance

N

Replace thermal well

values are correct. See page 25 to obtain water temperature.

 

(see page 26)

 

 

Are thermal well resistance values correct?

Y

Replace gas control

(see page 26)

Page 24

Page 24

24

Image 24
Contents Service Manual Through-The-Wall Gas Water Heaters For Your Safety Introduction How to Use This Manual Specifications Vent Tables Vent Tables Control Timings Sequence of Operation Steady state operation Pressure Switch/Blower Temperature Fault Troubleshooting Eight-one flash, three Vapor Sensor Burner Inspection and Air Shutter Adjustment Burner Cleaning Pilot Inspection, Testing and Replacement Pressure Switch Testing Pressure Switch Replacement Blower Testing Pressure tapRemove exhaust Blower Temperature Switch Testing Blower Temperature Switch Replacement Gas Control Testing Thermal Well TestingDetermine Water Temperature Inside Tank Gas Control & Thermal Well Removal From Water Heater Gas Control Removal From Thermal WellGas Control Assembly to Thermal Well Flammable Vapor Device Testing Safety Circuit Voltage Trace Red wire leading to blower temperature NVAC Circuit Trace Dip Tube Inspection and Replacement Anode Inspection and Replacement Remove blower to gain access to system from exhaust Flue baffleInner Door Removal Procedure Inner Door Gasket Replacement ProcedureInstallation of Inner Door With Gasket Replace outer jacket burner access door ScreenLok Flame Arrestor Cleaning Glossary of Terms Parts List Parts@bradfordwhite.com Techserv@bradfordwhite.com

M4TW40T*F, M1TW50S*F, M2TW50T*F, M4TW50T*F, M4TW60T*F specifications

Bradford-White Corporation is a leading manufacturer of water heating and storage solutions, known for its commitment to quality and innovation. Among its impressive product lineup, the M2TW65T*F, TW465S65F, TW450S65F, M1TW40S*F, and M1TW60T*F models stand out for their reliability and advanced technology suitable for both residential and commercial applications.

The M2TW65T*F model is distinguished by its high efficiency and performance. It features a 65-gallon capacity, which is ideal for households that require a significant amount of hot water. This model is equipped with an innovative electronic ignition system that enhances energy efficiency while providing reliable hot water on demand. Additionally, it includes advanced insulation technology that minimizes heat loss, ensuring that water remains hot for extended periods.

The TW465S65F and TW450S65F are other exemplary models in the Bradford-White lineup, boasting impressive storage capabilities. Both models offer a combination of a 65-gallon tank and powerful burner systems that significantly reduce recovery time, meaning users can enjoy hot water faster. These models are designed with a user-friendly control panel, making adjustments and monitoring water temperature straightforward. Their robust construction ensures durability and longevity, making them a smart investment.

For smaller households or spaces, the M1TW40S*F and M1TW60T*F models provide excellent options without compromising performance. The M1TW40S*F, with a 40-gallon capacity, is specifically designed for efficiency in limited spaces, while the M1TW60T*F offers extra capacity for larger demands. Both models utilize Bradford-White's state-of-the-art gas burner technology, promoting energy conservation while delivering consistent hot water.

All models are built with a high-quality glass-lined tank to protect against corrosion, further enhancing their lifespan. The incorporation of Bradford-White's exclusive EverKlean technology in their tank designs minimizes sediment buildup, ensuring clean and efficient operation over time.

In addition to their standout performance and efficiency, Bradford-White products prioritize safety. Built-in safety features, such as the temperature and pressure relief valve and advanced venting designs, provide peace of mind for users. These models not only meet but often exceed industry standards for safety and efficiency.

Bradford-White's commitment to innovation and quality is reflected in the M2TW65T*F, TW465S65F, TW450S65F, M1TW40S*F, and M1TW60T*F models, making them excellent choices for anyone in need of reliable hot water solutions. With their advanced technologies, durability, and energy efficiency, these water heaters are ideal for diverse applications in modern homes and businesses.