American Water Heater American Water Heaters Residential Gas Water Heater Typical Installation

Page 7
VACUUM RELIEF
VALVE
*INSTALL PER LOCAL CODES
* CAUTION HARNESS HAS 120 VAC. IN OPERATION.
** See “PLANNING THE VENT SYSTEM”, “CONDENSATE” and “BLOWER ASSEMBLY INSTALLATION” for more information.
***The side recirculation loop connections may not be used as the primary water inlet and outlet connections. For your convenience, plugs are installed in these fittings at the factory. Remove these plugs if needed for your specific installation. Otherwise (as with all connections) check for leaks while filling the tank with water and after completing the installation.
FIGURE 1 7

TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

AVent Pipe

BAnode

CHot Water Outlet

D Outlet (120 VAC)

FGas Supply

GMain Manual Gas Shuttoff Valve

HGround Joint Union J Sediment trap

KOuter Door

LUnion

MInlet Water Shuttoff Valve

NCold Water Inlet

OInlet Dip Tube

PTemperature & Pressure Relief Valve

Q

Rating Plate

H H

Bushing

R

Insulation

II

Nipple

S

Vent Terminal

JJ

Condensate Tee

T

Drain Valve

KK

Adapter

U

Igniter And Main Burner

LL

Plug

W

Drain Pan

MM

Vent Pipe Assembly #1

X

Gas Control Valve

NN

Vent Pipe Assembly #2

Y

Control Harness*

OO

Vent Pipe Assembly #3

AA

Motor & Blower

PP

Side Recirculation Loop

CC

Condensate Fitting

QQ

Inlet***

DD

(4 Places Shown)**

Side Recirculation Loop

Plastic Top

RR

Outlet*** (not shown)

EE

On/Off Switch

Vent Attenuation

FF

Exhaust Tee

SS

Assembly (VAA) (Optional)

GG

Elbow

Access Door

REPLACEMENT PARTS AND DELIMING

PRODUCTS

Replacement parts and recommended delimer may be ordered through authorized servicers or distributors. When ordering parts, provide complete model and serial numbers (see rating plate), quantity and name of part desired. Standard hardware items may be purchased locally.

SS

(SEE ACCESS

PANEL CAUTION)

W

PP

6 (15cm)

MAXIMUM AIR GAP

TO A SUITABLE

DRAIN

CONDENSATE ASSEMBLY

(U)NATURAL GAS MAIN BURNER

WITH IGNITER ASSEMBLY

SIDE VIEW

(X)

Image 7
Contents Printed Whenever maintenance adjustment or service is required319339-002 Approvals Safe INSTALLATION, USE and ServiceImportant Definitions General Safety Information General Safety Information Introduction Table of ContentsExemptions Installation of Carbon Monoxide DetectorsApproved Carbon Monoxide Detectors SignageReplacement Parts and Deliming Products Typical InstallationElbow Access Door Condensate Hose and Drain PAN Less Severe Burns 2nd & 3rd Degree Mixing ValvesFacts to Consider About the Location Locating the NEW Water HeaterAir REQUIREMENTs Insulation BlanketsOutdoor Air Through Two Openings Unconfined SpaceConfined Space Fresh Air Openings For Confined SpacesOutdoor AIR Through TWO Vertical Ducts Outdoor AIR Through TWO Horizontal DuctsAIR from Other Indoor Spaces Space Heating and Potable Water System Installing the NEW Water HeaterChemical Vapor Corrosion Water PipingThermal Expansion Temperature-Pressure Relief ValveValve and Pipe Insulation Gas Piping High Altitude InstallationFilling the Water Heater Sediment TrapsVenting Vent Pipe AssemblyVent Pipe Termination Termination Clearances Sidewall Power VentCondensate Planning the Vent SystemBreathing Hazard Carbon Monoxide Gas Installation of Vent System Blower Assembly InstallationVent Terminal INSTALLATION, Sidewall Power Vent Wiring Schematic Figure Sequence of INSTALLATIONS, FigureVent Termination Figure Installation of Vertical Vent System Installation of Vent SYSTEM, SidewallVertical VAA Installations Recommended Vent Attenuation Assembly InstallationInch vent Vertical VAA Installations Recommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep G Step BStep E Step FPage GAS Control Valve Front View Temperature RegulationOperational Conditions Periodic MaintenanceFor Your Information Start UP ConditionsAnode ROD Inspection Burner CleaningBurner Operation and Inspection HousekeepingTo Flush the Water Heater Storage Tank Temperature-Pressure Relief Valve TestDraining and Flushing To Drain the Water Heater Storage TankLeakage Checkpoints ServiceRepair Parts List LED Status Problem Solution Troubleshooting GuidelinesLED Status Problem Solution Troubleshooting Guidelines Page Fill in Warranty and Keep for Future Reference Limited Warranty