Burner OPERATION AND Inspection

Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

At least once a year a visual inspection should be made of the main burner and the hot surface igniter assembly for proper flame characteristics and ignition sequences. This can be done by removing the Outer Door and viewing the main burner operation through the Viewport on the Inner Door, see Figure 1. The main burner should provide complete combustion of gas, ignite rapidly, give reasonably quiet operation, and cause no excessive flame lifting from the burner ports. If the proper flame characteristics are not evident (see Figure 27), make sure that the flow of combustion and ventilation air is not blocked.

You should also check for sooting. Soot is not normal and will impair proper combustion. A visual inspection of the main burner and HSI should also be done at least once a year, see Figure 27.

Soot build-up indicates a problem that requires correction before

further use. Turn “OFF” gas to water heater and leave off until repairs

are made, because failure to correct the cause of the sooting can result

in a fire causing death, serious injury, or property damage.

FIGURE 27.

Burner Cleaning

In the event your burner or burner air openings require cleaning, turn the blower switch to the “OFF” position and allow the burner to cool. Call a service agency to remove and clean the burner and correct the problem that required the burner to be cleaned.

Housekeeping

Vacuum around base of water heater for dust, dirt, and lint on a regular basis.

INSTALLED IN SUITABLE AREA: To insure sufficient ventilation and combustion air supply, proper clearances from the water heater

must be maintained. See “Locating the New Water Heater” section. Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater which can cause a fire.

ANODE ROD INSPECTION

Each water heater contains at least one anode rod, which will slowly

deplete (due to electrolysis) prolonging the life of the water heater by

protecting the glass-lined tank from corrosion. Adverse water quality, hotter water temperatures, high hot water usage, and water softening methods can increase the rate of anode rod depletion. Once the anode rod is depleted, the tank will start to corrode, eventually developing a leak.

Certain water conditions will cause a reaction between the anode rod and the water. The most common complaint associated with the anode

rod is a “rotten egg smell” produced from the presence of hydrogen sulfide gas dissolved in the water. IMPORTANT: Do not remove this

rod permanently as it will void any warranties. The parts list includes a special anode rod that can be ordered if water odor or discoloration occurs. NOTE: This rod may reduce but not eliminate water odor problems. The

water supply system may require special filtration equipment from a water

conditioning company to successfully eliminate all water odor problems.

Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The use of a water softener may decrease the life of the water heater tank.

The anode rod should be removed from the water heater tank every 3 years for inspection. NOTE: artificially softened water requires the anode rod to be inspected annually.

The following are typical (but not all) signs of a depleted anode rod:

*The majority of the rods diameter is less than 3/8”.

*Significant sections of the support wire (approx. 1/3 or more of the anode rod’s length) are visible.

If the anode rod show signs of either or both it should be replaced.

NOTE: Whether re-installing or replacing the anode rod, check for any leaks and immediately correct if found.

In replacing the anode:

1.Turn off gas supply to the water heater.

2.Shut off the water supply and open a nearby hot water faucet to depressurize the water tank.

3.Drain approximately 5 gallons of water from tank (Refer to “Draining and Flushing” for proper procedures). Close drain valve.

4.Remove old anode rod.

5.Use Teflon® tape or approved pipe sealant on threads and install new anode rod.

6.Turn on water supply and open nearby hot water faucet to purge air from water system. Check for any leaks and immediately correct any if found.

Restart the water heater as directed under “Operating Your Water Heater.” See the Repair Parts Illustration for anode rod location.

FIGURE 28. ANODE ROD DEPLETION.

31

Image 31
Contents Printed Whenever maintenance adjustment or service is required319339-002 Approvals Safe INSTALLATION, USE and ServiceImportant Definitions General Safety Information General Safety Information Introduction Table of ContentsExemptions Installation of Carbon Monoxide DetectorsApproved Carbon Monoxide Detectors SignageReplacement Parts and Deliming Products Typical InstallationElbow Access Door Condensate Hose and Drain PAN Less Severe Burns 2nd & 3rd Degree Mixing ValvesFacts to Consider About the Location Locating the NEW Water HeaterAir REQUIREMENTs Insulation BlanketsOutdoor Air Through Two Openings Unconfined SpaceConfined Space Fresh Air Openings For Confined SpacesOutdoor AIR Through TWO Vertical Ducts Outdoor AIR Through TWO Horizontal DuctsAIR from Other Indoor Spaces Space Heating and Potable Water System Installing the NEW Water HeaterChemical Vapor Corrosion Water PipingThermal Expansion Temperature-Pressure Relief ValveValve and Pipe Insulation Gas Piping High Altitude InstallationFilling the Water Heater Sediment TrapsVenting Vent Pipe AssemblyVent Pipe Termination Termination Clearances Sidewall Power VentCondensate Planning the Vent SystemBreathing Hazard Carbon Monoxide Gas Installation of Vent System Blower Assembly InstallationVent Terminal INSTALLATION, Sidewall Power Vent Wiring Schematic Figure Sequence of INSTALLATIONS, FigureVent Termination Figure Installation of Vertical Vent System Installation of Vent SYSTEM, SidewallVertical VAA Installations Recommended Vent Attenuation Assembly InstallationInch vent Vertical VAA Installations Recommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep G Step BStep E Step FPage GAS Control Valve Front View Temperature RegulationOperational Conditions Periodic MaintenanceFor Your Information Start UP ConditionsAnode ROD Inspection Burner CleaningBurner Operation and Inspection HousekeepingTo Flush the Water Heater Storage Tank Temperature-Pressure Relief Valve TestDraining and Flushing To Drain the Water Heater Storage TankLeakage Checkpoints ServiceRepair Parts List LED Status Problem Solution Troubleshooting GuidelinesLED Status Problem Solution Troubleshooting Guidelines Page Fill in Warranty and Keep for Future Reference Limited Warranty
Related manuals
Manual 40 pages 29.25 Kb

American Water Heaters Residential Gas Water Heater, VG6250T76NV Series 100 specifications

The American Water Heater VG6250T76NV, part of the VG6250T76NV Series 100, stands out as a reliable and efficient option for residential water heating needs. This model is designed to offer optimal performance and longevity, making it an ideal investment for any homeowner.

One of the main features of the VG6250T76NV is its impressive capacity. With a 50-gallon tank, it can provide ample hot water for families with multiple bathrooms, ensuring that everyone has enough hot water for showers, laundry, and dishwashing without running out. This feature is particularly beneficial for busy households where hot water demand can be high.

The VG6250T76NV is equipped with a highly efficient gas burner system. This system not only reduces heating times but also enhances energy savings, allowing homeowners to save on their utility bills. The gas burner provides quick recovery rates, meaning that users will not experience long waits for hot water after heavy usage.

Another significant aspect of this water heater is its innovative insulation design. The tank features high-density foam insulation that minimizes heat loss, which helps to maintain water temperature for longer periods. This insulation technique also contributes to overall energy efficiency, making it an environmentally friendly choice.

Safety is also a top priority with the VG6250T76NV. It includes a reliable temperature and pressure relief valve to prevent overheating and potential hazards. Additionally, it is equipped with a built-in safety shut-off feature, ensuring peace of mind for homeowners.

The VG6250T76NV is designed with user-friendliness in mind. It features an adjustable thermostat that allows for easy temperature control, as well as a side-mounted tap for flexible installation options. The unit has a robust construction that ensures durability, with a corrosion-resistant tank that helps extend its lifespan.

With a limited warranty, the American Water Heater VG6250T76NV provides additional assurance of quality and performance. This water heater combines advanced technology, thoughtful design, and efficient operation to deliver a product that meets and exceeds consumer expectations. Overall, the VG6250T76NV Series 100 is an excellent choice for anyone looking to upgrade their home’s hot water supply system.