A.O. Smith BTH 120-250(A) warranty ECO Switch Open Figure, Control BAD Figure

Page 17

Display Flashes “05” when button is pressed:

 

 

 

 

 

 

 

Possible Cause

Remedy

 

 

 

 

 

 

 

1.

Temperature Probe wiring

1. Repair Wiring

 

 

 

open

 

 

 

2.

Defective probe

2. Replace probe

 

 

 

 

 

 

 

 

 

 

 

Display Flashes “15” when button is pressed:

 

 

 

 

 

 

Possible Cause

Remedy

 

 

1.

No water in tank and tank

1. The symptom does not

 

 

 

in freezing conditions

reflect a control problem

 

 

2.

Water in tank above freezing

2. Temperature probe out of

 

 

 

 

tolerance, replace temp.

 

 

 

 

probe

 

 

 

 

 

 

 

 

 

 

 

Display Flashes “25” when button is pressed:

 

 

 

 

 

 

 

 

Possible Cause

 

Remedy

 

 

 

 

 

 

 

 

1.

Water in tank is low, probe

1.

Fill tank

 

 

 

immersed in steam

 

 

 

 

2.

Probe wiring shorted

2.

Repair wiring

 

 

3.

Defective probe

3.

Replace probe

 

 

 

 

 

 

 

 

 

 

 

 

 

ECO SWITCH OPEN (Figure 22)

ECO LED Flashing:

ECO SWITCH OPEN, ECO LED Flashing

FIGURE 22

 

 

 

 

 

Possible Cause

Remedy

 

 

1. This indicates the control has

1. Press button on the

 

 

failed on of its internal

display board to reset

 

 

diagnostic self-tests.

control. If this error

 

 

 

occurs repeatedly,

 

 

 

replace control.

 

 

 

 

 

 

 

 

 

CONTROL BAD (Figure 23)

 

 

All LEDs Flashing:

 

 

CONTROL BAD, All LEDs Flashing

FIGURE 23

 

Possible Cause

Remedy

 

 

 

 

1.

Temp. Probe unplugged

1. Check connectors

2.

Temp. probe wiring damaged

2. Repair wiring

3.

Water in tank too hot

3. Normal condition when

water t e m p e r a t u r e exceeds safety limit. Allow water to cool or admit water into tank and manually reset the control. Determine cause for overtemp condition.

COMBUSTION AIR BLOCKAGE (Figure 24)

Pressure Switch LED Flashing:

COMBUSTION AIR BLOCKAGE, Pressure Switch LED Flashing

FIGURE 24

Possible Cause

 

Remedy

 

 

 

 

 

1.

Combustion air blocked

1.

Check exhaust piping and

 

 

 

flue for obstructions

2.

Blower not operating:

2.

a. Repair wiring

 

a. Check blower wiring

 

b. Replace blower motor

 

b. Check blower motor

 

 

3.

Defective air switch

3.

Replace air switch

4.

Pressure switch jumped out

4.

This controller must sense

 

 

 

an open contact on the

 

 

 

blower proving airflow

 

 

 

switch before the blower

comes on. Check to see if blower proving airflow switch is still connected to the unit.

17

Image 17
Contents What to do if YOU Smell GAS Cyclone XHE Model BTH 120-250AForeword Cyclone XHE BTH 120 250 ROUGH-IN-DIMENSIONSBTH-120 NPT BTH-150 199 InputFeatures Table of ContentsInstallation Instructions Clearances Locating the HeaterAIR Requirements Hard WaterChemical Vapor Corrosion Mechanical Exhausting of Room AIRHorizontal Vent Direct VentDirect Venting Direct Vent Terminal InstallationTransmitted Into the Living Spaces 6cm 45 PVC Elbow with Mesh ScreenVent terminals supplied with the heater must be used Installation SequenceInstallation of Vent System Vertical Vent Terminal InstallationVent Pipe Preparation Controls and SwitchesBlower Prover Switch GAS Piping System Connections Heater Wiring WHC1202 Integrated Water Heater Control Connection Diagram Water Line Connections Closed SystemOperation Self Diagnostic ControllerSequence of Operation Item DescriptionTemperature Probe Fault Figure Fault ConditionsGAS Valve LED Flashing No Incoming Line Voltage Line LED OffCombustion AIR Blockage Figure ECO Switch Open FigureControl BAD Figure Prior to Start UP Adjustment ProcedureOperating Instructions Initial START-UPFor Your Safety Read Before Operating General Information MaintenanceFlushing Anode Inspection and ReplacementDraining Sediment RemovalTo inspect or replace an anode Drain Valve and Access PanelsVent System Installation Diagrams Install in Accordance with Local Codes Must be Identical Heaters Pipe Relief Valve to Open Drain Page Manifold Kits TROUBLE-SHOOTING Checklist and Service InformationMotor will not RUN Replacement PartsMotor RUNS, Burner Lights Momentarily Then Locks OUT Noisy Burner OperationClaim Procedure Service and Repair ExpensesTank ALL Other PartsSmith Water Products Company