Genie 3452535556 PCG, 3452535556 GCG Open RED Parts BAG, Wiring cont’, Check the following

Page 16

OPEN RED PARTS BAG

3.Wiring (cont’).

Securely fasten wires to wall as you go.

Use insulated staples (included).

16

[30]

Staples should be snug only.

CAUTION

Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the “STB” System to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snuggly.

Make wire attachments at STBs.

Splitting and stripping wire ends to be connected as shown (Fig. 3-6).

Loosen terminal screws.

Insert wire under flat plate and tighten screw. It does not matter which wire, white or striped, goes on which terminal (Fig. 3-7).

Make wire attachments at power head.

STBsare connected to terminals #2 and #3 on power head (Fig. 3-8).

4.Check the following.

Insure that no part of door or its hardware is in path between lenses of source and sensor.

Insure that tops of lenses are between 5"-6" above the floor (Fig. 3-9). The brackets are flexible, and can be adjusted slightly if needed.

NOTE: Safe-T-Beam ® alignment check must be performed following connection to electrical power (see page18). DO NOT PLUG IN YET!

FIG. 3-6 Splitting and stripping.

FIG. 3-7 Terminal attachments at STB.

2

3

FIG. 3-8 Terminal attachments at power head.

top edge of lens between 5" - 6" above floor.

FIG. 3-9 Check lens height.

Image 16
Contents Series GCG, PCG, H Things to consider if you are planning to do-it-yourself Typical Sectional Door Installation Typical 1-PIECE Door InstallationOperator Features Table of ContentsSafety Features Recommended Tools Parts Identification Not Shown Full SizePiece Rail Hardware Exploded View Power Head Exploded View Parts ListSafety Information Operator Assembly Open Blue Parts BAGAttach rail to power head Open Green Parts BAGSlip carriage into carriage slot of rail Slip opposite no knot end through knobAttach limit switches Attach limit switch wiresInstallation Header and Door Mounting BracketsFinding header bracket mounting location Marking final heightOpen Orange Parts BAG Door Bracket12 2. Mounting the header bracket Finding door bracket mounting locationMounting the Operator Open Yellow Parts BAG Connecting the armsAttach the arms SAFE-T-BEAM System Installation Open RED Parts BAG Wiring cont’Check the following Wall Control Installation WiringFinding the mounting location MountingWith Permanent Wiring Instructions for electricianLimit Switch / Force Adjustment Adjusting limit switchesAdjusting Open force Adjusting Close forceProgramming Remote Controls Single Button Remote Contact Reverse TestRemote Control Light BULB/LENS InstallationMULTI-BUTTON Remote Lost or Stolen RemoteMaintenance Routine Monthly Maintenance Troubleshooting GuideDoor springs and hardware Door balanceRemote control Door operatorStarts for No reasonWiring Diagram Transmitter Compliance StatementDistributor Garage Door Operator Accessories Order Form Genie CompanyLimited Warranty