Genie 3452535556 Limit Switch / Force Adjustment, Adjusting limit switches, Adjusting Open force

Page 19

6LIMIT SWITCH / FORCE ADJUSTMENT

WARNING

DOOR OPENS RAPIDLY.

Keep the path clear.

Position the ladder to the side of the power head so it is clear of all moving parts of the operator and door.

Always set the door operator to the minimum force required to operate the door.

NOTE: During operator cycling for force adjustment, the motor protector may shut off power to the operator. If this occurs, wait about 20 minutes to allow the motor protector to reset.

1.Adjusting limit switches.

Locate force control knobs on power head (Fig. 7-1).

Gently turn both control knobs counter-clockwise until they stop.

Verify emergency release lever in disengaged position.

Verify “OPEN” limit switch at point where chain attaches to carriage slide (Fig. 7-2).

Manually close door.

Move the “CLOSE” limit switch:

Loosen set screw.

Slide limit switch along rail to align front edge of switch with back edge of carriage (Fig. 7-3).

Gently tighten set screw.

Press wall control button.

Carriage slide will move toward power head and stop at the “OPEN” limit switch.

Manually open door.

Move the “OPEN” limit switch:

Loosen set screw.

Slide limit switch along rail to align front edge of switch with back edge of carriage (Fig. 7-4).

Gently tighten set screw.

Manually close door.

Place emergency release lever in engaged position.

Press wall control button.

Carriage slide will move toward door, engage with carriage and stop at “CLOSE” limit switch.

2.Adjusting “OPEN” force.

Press wall control button.

Door should open and stop at “OPEN” limit.

Door does not fully open.

Press wall control button.

Door should close and stop at “CLOSE” limit.

Turn “OPEN” force control knob slightly in clockwise direction.

Press wall control button.

a. Continue step 2 until door opens completely.

3.Adjusting “CLOSE” force.

Door is not fully closing.

Cycle door, turning “CLOSE” force knob clockwise slightly each time until door reaches fully closed.

FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM

FIG. 7-1 Force adjustment screws.

FIG. 7-2 Place “Open” limit switch.

FIG. 7-3 Align “CLOSE” limit switch.

19

FIG. 7-4 Align “OPEN” limit switch.

Image 19
Contents Series GCG, PCG, H Things to consider if you are planning to do-it-yourself Typical 1-PIECE Door Installation Typical Sectional Door InstallationOperator Features Table of ContentsSafety Features Parts Identification Not Shown Full Size Recommended ToolsPiece Rail Hardware Exploded View Power Head Exploded View Parts ListSafety Information Open Blue Parts BAG Operator AssemblySlip opposite no knot end through knob Attach rail to power headOpen Green Parts BAG Slip carriage into carriage slot of railAttach limit switch wires Attach limit switchesMarking final height InstallationHeader and Door Mounting Brackets Finding header bracket mounting locationFinding door bracket mounting location Open Orange Parts BAGDoor Bracket 12 2. Mounting the header bracketMounting the Operator Open Yellow Parts BAG Connecting the armsAttach the arms SAFE-T-BEAM System Installation Open RED Parts BAG Wiring cont’Check the following Mounting Wall Control InstallationWiring Finding the mounting locationInstructions for electrician With Permanent WiringAdjusting Close force Limit Switch / Force AdjustmentAdjusting limit switches Adjusting Open forceContact Reverse Test Programming Remote Controls Single Button RemoteLost or Stolen Remote Remote ControlLight BULB/LENS Installation MULTI-BUTTON RemoteDoor balance Maintenance Routine Monthly MaintenanceTroubleshooting Guide Door springs and hardwareNo reason Remote controlDoor operator Starts forTransmitter Compliance Statement Wiring DiagramDistributor Genie Company Garage Door Operator Accessories Order FormLimited Warranty