Genie 3452535556 Maintenance Routine Monthly Maintenance, Troubleshooting Guide, Door balance

Page 22

22

IMPORTANT SAFETY INSTRUCTIONS

WARNING:

Toreduce the risk of severe injury or death:

1.READ AND FOLLOW ALL INSTRUCTIONS.

2.Never let children operate or play with the door controls. Keep the remote control away from children.

3.Always keep the moving door in sight and away from people and objects until the door is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4.NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5.Test operator monthly. The door MUST reverse on contact with a 11/ 2" high object (or a 2" x 4" board laid flat) at the center of the doorway on the floor. After adjusting either the force or the limit of travel, retest the door Opener. Failure to adjust the Opener properly may cause severe injury or death.

6.When possible, use the emergency release only when the door is closed. Use caution when using this release with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death.

7.KEEP DOORS PROPERLY BALANCED. See Owner’s Manual. An improperly balanced door increases the risk of severe injury or death. Have a qualified service person make repairs to cables, spring assemblies, and other hardware.

8.SAVE THESE INSTRUCTIONS.

10 MAINTENANCE

ROUTINE MONTHLY MAINTENANCE

1.Door springs and hardware.

Do not operate garage door automatically or manually if springs are broken.

CONTACT A PROFESSIONAL FOR SERVICE.

2.Door balance.

Close the door.

Pull emergency release knob down to release door from carriage assembly.

Raise door manually approximately 3 feet.

Door should stay in that position or close very slowly.

If door moves quickly, HAVE DOOR SERVICED BY A PROFESSIONAL.

Close the door.

Pull emergency release knob toward power head to place release lever in engaged position.

Operate door using remote.

Door will re-attach itself to carriage assembly.

3.Contact reverse.

Place a 2" x 4" board laid flat on floor.

In center of garage door opening.

Close door by using wall button or remote control.

Door fails to reverse on contact with board see Section 7 “CONTACT REVERSE.

Operator still fails CONTACT A SERVICE PROFESSIONAL.

4.Safe-T-Beam®System.

Use Self-Diagnostic STB system Troubleshooting information to maintain safe operation (Below).

TROUBLESHOOTING GUIDE

Use This Guide To Correct Problems With Door Operator.

If These Solutions Do Not Work,

Call Customer Service at 1.800.35.GENIE

SELF-DIAGNOSTIC

STB SYSTEM TROUBLESHOOTING

SOURCE

SENSOR

INDICATED

REQUIRED

RED LED

GREEN LED

CONDITION

ACTION

 

 

 

 

 

ON

ON

NORMAL OPERATION

NONE REQUIRED

 

 

 

 

 

OFF

OFF

1. POWER HEAD NOT

1. CHECK BREAKERS,

 

 

POWERED

FUSES, PLUGS

 

 

2. WIRING FROM

2. CHECK WIRING FOR

 

 

POWER HEAD BAD

OBVIOUS SHORTS

OFF

ON

1. WIRING TO

1. CHECK WIRING

 

 

SOURCE MISSING

 

 

 

 

OR BAD

2. REMOVE POWER

 

 

2. POWER HAS BEEN

 

 

AND REAPPLY

 

 

INTERRUPTED

 

 

 

 

 

 

 

 

 

 

ON

1. BEAM NOT ALIGNED

1. CHECK ALIGNMENT

 

2. BEAM OBSTRUCTED

2. CHECK FOR

2 BLINKS, PAUSE

 

 

 

OBSTRUCTION

(REPEAT)

 

 

 

3. SENSOR DEFECTIVE

3. CALL CUST. SERV.

 

 

 

 

OFF

1. WIRE TO SENSOR

1. CHECK WIRING

 

MISSING OR BAD

 

 

2 BLINKS, PAUSE

 

 

 

 

2. SENSOR DEFECTIVE

2. CALL CUST. SERV.

(REPEAT)

 

 

 

 

 

 

ON

1. SENSOR RECEIVING

1. ATTEMPT TO

 

INTERFERENCE

DETERMINE SOURCE

 

 

3 BLINKS, PAUSE

 

 

OF INTERFERENCE

(REPEAT)

 

 

2. CALL CUST. SERV.

 

 

 

 

 

ON

1. SOURCE NOT

1. CALL CUST. SERV.

 

SENDING PULSES

 

 

4 BLINKS, PAUSE

 

 

 

 

2. SOURCE DEFECTIVE

2. CALL CUST. SERV.

(REPEAT)

 

 

 

 

NOTE: IF OPERATING PROBLEM EXISTS, THE DOOR CAN BE CLOSED IF YOU:

DISCONNECT THE STB SYSTEM FROM THE OPERATOR

HOLD WALL CONTROL BUTTON DOWN UNTIL DOOR IS CLOSED (REMOTE CONTROL & WIRELESS KEYPAD WILL NOT WORK WITHOUT STB)

For Answers: CALL CUSTOMER SERVICE at 1.800.35.GENIE

Image 22
Contents Series GCG, PCG, H Things to consider if you are planning to do-it-yourself Typical Sectional Door Installation Typical 1-PIECE Door InstallationOperator Features Table of ContentsSafety Features Recommended Tools Parts Identification Not Shown Full SizePiece Rail Hardware Exploded View Power Head Exploded View Parts ListSafety Information Operator Assembly Open Blue Parts BAGSlip carriage into carriage slot of rail Attach rail to power headOpen Green Parts BAG Slip opposite no knot end through knobAttach limit switches Attach limit switch wiresFinding header bracket mounting location InstallationHeader and Door Mounting Brackets Marking final height12 2. Mounting the header bracket Open Orange Parts BAGDoor Bracket Finding door bracket mounting locationMounting the Operator Open Yellow Parts BAG Connecting the armsAttach the arms SAFE-T-BEAM System Installation Open RED Parts BAG Wiring cont’Check the following Finding the mounting location Wall Control InstallationWiring MountingWith Permanent Wiring Instructions for electricianAdjusting Open force Limit Switch / Force AdjustmentAdjusting limit switches Adjusting Close forceProgramming Remote Controls Single Button Remote Contact Reverse TestMULTI-BUTTON Remote Remote ControlLight BULB/LENS Installation Lost or Stolen RemoteDoor springs and hardware Maintenance Routine Monthly MaintenanceTroubleshooting Guide Door balanceStarts for Remote controlDoor operator No reasonWiring Diagram Transmitter Compliance StatementDistributor Garage Door Operator Accessories Order Form Genie CompanyLimited Warranty