Genie 3627336241 General Troubleshooting Always Check the Status LED Light, Problem What To Do

Page 12

 

General Troubleshooting (Always Check the Status LED Light)

Problem

 

 

What To Do

Opener does not run

 

1. Check power source.

from Remote Control

 

A. If Opener is connected to an outlet :

 

 

Plug a working lamp into outlet used for Power Head.

 

 

If lamp glows, power source and outlet are OK.

 

 

If not, check fuse or circuit breaker or non-compatible GFCI.

 

 

NOTE: A licensed electrician must replace non-compatible GFCI’s.

 

 

B. If Opener is connected to a wiring box:

 

 

Check that fuse is not blown, or circuit breaker is on and not tripped or off..

 

 

If still no power, have a licensed electrician check circuit and wiring.

 

 

2. If Power Source is OK :

 

 

Check Power Head Terminal connections (Wall Console Installation on Assembly & Installation Poster), tighten if loose..

 

 

Check connections at Wall Console Terminals, tighten any loose connections..

 

 

Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive

 

 

Board is properly connected to Connectors on Circuit Boards, or call Customer Service at 1-800-35-GENIE..

 

 

 

 

Door Opener starts

 

Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires).

for no apparent reason

 

 

Replace any shorting Staples and shorted Wires.

 

 

Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory

 

 

 

and reprogram for remaining remote controls.. (See Erase All Receiver Memory on page 8)..

 

 

Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls..

Door starts down, then

 

Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 7).

stops before it is

 

 

Adjust as needed.

completely closed

 

Check for shorted Wires.

 

 

Check garage door for binding..

Door starts down, then

 

If a new installation, check Door Arm position.

stops and goes back up

 

Check operation of Contact Reverse function.

 

 

Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.

 

 

Check Safe-T-Beam® System diagnostic code.

 

 

Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed.

 

 

Check garage door for binding..

Door will only run closed

 

Check Open Limit Switch for a short circuit and for proper wiring.

 

 

Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed.

 

 

Check condition of garage door and door spring(s).

 

 

 

•WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie

 

 

 

Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE..

 

 

 

 

Door will only run open

 

Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart

 

 

 

(see Safe-T-Beam® System Self-diagnostic Troubleshooting Section on page 13)..

 

 

Check Close Limit Switch for a short circuit and for proper wiring.

 

 

Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed..

Lights will not go out

 

Disconnect Wires connected to Wall Console.. (Wall Console Installation on Assembly & Installation Poster)..

 

 

 

Check their condition and either replace or reconnect..

 

 

Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls

 

 

 

or Wireless Keypad to operate Opener.

 

 

 

 

Door starts up, but stops

 

Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly

before it is

 

 

balanced as detailed in Maintenance Section.

completely open

 

WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie

 

 

 

Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE..

 

 

Check Open Limit Switch for a short circuit and for proper wiring.

 

 

Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed..

Operator runs, but door

 

Ensure Magnetic Carriage Assembly is engaged to Rail Drive Screw (see Install Magnetic Carriage Assembly

does not move

 

 

onto Rails on page 10).

 

 

Check Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed.

 

 

Check that all sections of Rail Drive Screw are turning when Motor runs.. If not:

 

 

 

– Check condition (not cracked, split, or broken) and placement of Coupler.. Replace as needed.

 

 

 

– Check condition (not cracked, split, or broken) and placement of Collar and Clip.. Replace them

 

 

 

as needed..

 

 

 

 

Wall Console Vacation

 

Ensure Magnetic Carriage Assembly is in contact with Close Limit Switch.

Lock function does

 

Check when door is fully closed, that Carriage activates Close Limit Switch.. If not, adjust position of Close

not work

 

 

Limit Switch (See page 7).

 

 

 

 

continued on next page

12

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Image 12
Contents DC Powered Screw Drive Opener Manual 1 Warranty Information Genie Company Limited WarrantyService From Authorized Dealers What this warranty does not coverSafety Features Instructions­Tools used in this section Check following items before assembling OpenerCheck Check Ceiling for Grounded Power Source Mounting AreaMounting Bracket Location Check Recommended tools Check emove xisting arage Door LocksWood for header, ceiling, and/or door braces store Test Opener monthly.. The door Must reverse on contact withLittle effort is required to turn the Force Adjusting Knobs Adjustment 1 Adjusting Limit Switches and Force ControlsDo Not Unplug the Unit simply wait On pgAccessories Each Remote Control must be programmed separatelyTransmitter Compliance Statement Moving garage door may cause serious injury or deathInstall Light Bulbs and Lens Remote Control OperationTo Erase All Remotes from Power Head Memory To Replace Remote Control BatterySafe-T-Beam System Self-Diagnostic Troubleshooting Source Red LED Sensor Green LED Possible Problem SolutionGenie BLINKS, PauseYou See Problem What to Do Reference Door hardware or rollers may result in a ONE-BLINK signalCheck door condition.. Note This Opener is equipped with an OpenerGeneral Troubleshooting Always Check the Status LED Light Problem What To DoWiring Diagram Opening Cover May Result in Electric ShockPower Head Assembly Exploded View QuantityPart Name Hardware Exploded View Instructions Commandant Ordering InstructionsLas Instrucciones que Ordenan

3627336241 specifications

Genie 3627336241 is a cutting-edge machine that exemplifies the perfect blend of advanced features, innovative technologies, and remarkable characteristics. Designed primarily for enhancing productivity and efficiency, this equipment is widely regarded in the construction and maintenance sectors.

One of the standout features of the Genie 3627336241 is its exceptional lifting capability. With a maximum working height of approximately 36 feet, it provides operators with the ability to access elevated areas with ease. Its robust platform can accommodate a significant workload, making it ideal for various tasks such as electrical work, painting, and installation of infrastructure.

Safety is paramount when it comes to the Genie 3627336241. Equipped with advanced safety systems, including a secure ground control, tilt-level sensors, and emergency stop features, it ensures that operators can work confidently at heights. The non-slip surface of the platform further adds an extra layer of safety, making it a reliable choice for demanding environments.

The Genie 3627336241 is powered by a highly efficient electric drive system. This technology not only enhances energy efficiency but also minimizes environmental impact, making it a sustainable option for today's eco-conscious businesses. The quiet operation of the machine allows for use in noise-sensitive environments without disturbing surrounding activities.

Mobility is another key characteristic of the Genie 3627336241. The compact design, combined with durable rubber tires, enables smooth maneuverability across various terrains. Whether navigating indoor spaces or uneven outdoor surfaces, it offers stability and ease of movement.

In terms of operator comfort, the Genie 3627336241 features an ergonomic control layout. Controls are designed for intuitive operation, reducing the learning curve for new users while enhancing productivity for experienced operators. The spacious platform also allows for multiple workers to operate simultaneously, increasing overall efficiency on job sites.

Durability is integral to the design philosophy behind the Genie 3627336241. Constructed with high-quality materials, this machine withstands the rigors of everyday use, ensuring longevity and low maintenance costs. The reinforced frame and corrosion-resistant components contribute to its reliability and performance over time.

In conclusion, the Genie 3627336241 stands as a testament to innovation in the equipment industry. With its impressive height capabilities, advanced safety features, eco-friendly operation, and user-centric design, it represents an invaluable asset for professionals seeking to enhance productivity and efficiency in their operations. This machine is engineered to meet the demands of modern workspaces, making it a preferred choice for various applications in construction and maintenance industries.