Genie 3681036666 warranty General Troubleshooting, Problem, Openerdoesnot run from WallControl

Page 11

Problem

Openerdoesnot run from WallControl

Door Opener starts

for no apparent reason

Door starts down, then stops before it is completely closed

Door starts down, then stops and goes back up

Door will only run closed

Doorwill onlyrunopen

Lights will not turn off

Door startsup,

but stops beforeit is completelyopen

Operator runs, but door does not move

Wall ConsoleVacation Lock function does not work

Noisy Operation

General Troubleshooting

What To Do

1.Check Lock switch on Wall Control Installation Poster.

2.Check Power Source:

For Grounded Plug Connection.

-Plug a lamp into the electrical outlet used for the door opener.

a.If lamp lights, power source is good.

b.If lamp does not light, check fuse or circuit breaker.

For Permanent Wiring Connection.

-Check fuse or circuit breaker.

3.Check connections (see Wall Console Installation on Installation Poster):

At Power Head Terminals and Wall Control.

1.Check Wires to ensure that they are not cut (Staples can cut insulation and short Wires) Replace any shorting Staples and shorted Wires.

2.Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver'smemory and reprogram for remaining remote controls. (See EraseAll Receiver Memory on page 8).

3.Ensure that no Buttons are stuck "pushed-in" on Wall Console or any Remote Controls.

1.Check Close Limit Switch setting (page 7 and poster). Adjust as needed.

2.Check Force Setting (pages 7).Adjust as needed.

3.Check for shorted wires.

1.Ifa new installation, check Door Arm position.

2.Check operation of Contact Reversefunction.

3.Check Safe-T-Beam® Systemfor beam obstruction or misalignment of Lenses.

4.Check Safe-T-Beam® System diagnostic code.

5.Check CloseForceadjustment (seeSet Limit Switches and Force Controls on pages 7). Adjust as needed.

6.Check garage door for binding.

1.Check Open Limit Switch for a short circuit and for proper wiring.

2.Check Open Force adjustment (seeSet Limit Switches and ForceControls on pages 7). Adjust as needed.

3.Check condition of garage door and door spring(s).

4.WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie Factory Authorized Dealer for service,or contact Customer Serviceat 1-800-35-GENIE.

5.CheckPosition of Lock Switch on Console.

1.CheckSafe-T-Beam® Systemas detailed in the Safe-T-Beam® System Self-diagnosticTroubleshooting Chart (page 10).

2.CheckCloseLimit Switch for a short circuitand for proper wiring.

3.CheckCloseForceadjustment (seeSet Limit Switches and Force Controlson pages 7). Adjust asneeded.

1.Disconnect Wires connectingPushbutton to Power Head(seePushbutton Installation on poster). Checktheir conditionand either replaceor reconnect.

2.Until a replacement Wall Consolecan be obtained, disconnect Wall Consoleand use only Remote Controls or Wireless Keypadto operate Opener.

3.Check for non-compatible wall control.

1.Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly balanced as detailed in Maintenance Section.

2.WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie Factory Authorized Dealer for service, or contact Customer Serviceat 1-800-3S-GENIE.

3.CheckOpen Limit Switch for a short circuitand for proper wiring.

4.CheckOpen Forceadjustment (seeSet Limit Switches and ForceControlson pages 7). Adjust as needed.

1.EnsureCarriageAssembly is engaged to CarriageSlide (seeInstallCarriageAssemblyonto Railson InstallationPoster).

2.CheckForceadjustment (seeSet Limit Switches and Force Controlson pages 9 and 10). Adjust as needed.

1.EnsureCarriageAssembly is in contactwith CloseLimit Switch.

2.Checkwhen door is fully closed,that Carriageactivates CloseLimit Switch. If not, adjust position of Close Limit Switch (Seepages 7).

1.Be sure all fastenersare tight.

2.Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly balanced as described in Maintenance Section (page 10).

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

11

Image 11
Contents Remote Control and Seriesii Table of ContentsInstructions Serial/Mfg NoSerial Number DealerAddress CityManual Emergency Release Safe-T-ReverseContact Reversing SystemSafe-T-StopTimed Reversed System ForceGuard ControlSectional Door ONE-PIECE Door PRE=INSTALLATION ChecklistTools used in this section Check following items before assembling OpenerMOUlJ PowersourceShou d be hand ed ONLYby a trained professiona Readandfollowallinstructions LwarningForce Located Under Light Cover Close Class 2 Supply Coarse Setting of Limit SwitchesSetting Force Controls and Final Adjustment Limit Switches ForcecontrolsReversefunction AccessoriesTo Replace Remote Control Battery Remote Control OperationReadand Followallinstructions INSTALLATiON of Lensand BulbCompliance Source Red LED Troubleshooting GuideSafe=T=Beam System Self=Diagnostic Troubleshooting Possible ProblemDoorwill onlyrunopen General TroubleshootingProblem Openerdoesnot run from WallControlYellow Power Head Parts List NumberParts MLRParts i Dentification Parts ListSTB Instructions CommandantOrdering Instructions
Related manuals
Manual 14 pages 1.8 Kb