Hitachi FD2 1590 important safety instructions Fire and Explosion Hazard

Page 4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

Warning

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground equipment and conductive objects in work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop operating and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com- ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only.

Do not alter or modify equipment.

For professional use only.

Use equipment only for its intended purpose. Call your Graco distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not use hoses to pull equipment.

Comply with all applicable safety regulations.

BURN HAZARD

Equipment surfaces and fluids that are heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.

4

311879F

Image 4
Contents Important Safety Instructions Instructions Parts ListII 2 G Contents Certificate of Conformance Fire and Explosion Hazard Toxic Fluid or Fumes Hazard Installation General InformationTightening Clamps Before First Use GroundingAir Line MountingsFluid Suction Line Fluid Outlet Line KeyChanging the Orientation of the Fluid Inlet Outlet Ports Air Exhaust Ventilation Venting Exhaust AirPressure Relief Procedure Starting and Adjusting the PumpOperation Sanitize the Pump Before First UseOperation Maintenance Preventive Maintenance ScheduleLubrication FlushingTroubleshooting Problem Cause SolutionTroubleshooting Service Repairing the Air ValveDisassembly ReassemblyTorque to 52-60 in-lb Ball Check Valve Repair Tools RequiredStandard Diaphragm Repair Reassembly Cutaway view, with diaphragms in place Heavy-Duty Diaphragm Repair 24 104 403 106 101 Bearing and Air Gasket Removal Detail of air valve bearings FDA-Compliant Stainless Steel Sanitary Pumps Pump MatrixFD1111 FD1122 FD1211 FD1222 FD1113 FD1213 FD1132 FD1232 Repair Kit Matrix For 1040 Stainless Steel Sanitary PumpsFK1111 FK1111 FK1122 FK1211 FK1222 FK1113 FK1213 FK1132 FK1232Parts Detail of Heavy-Duty DiaphragmAir Motor Parts List Matrix Column Fluid Section Parts List Matrix Column Seat Parts List Matrix ColumnBall Parts List Matrix Column Diaphragm Parts List Matrix ColumnPump Mounting Dimensional Drawing1040 FDA Technical Data Wetted materials on all models SSTPerformance Chart Fluid Pressure CurvesTo find Fluid Outlet Pressure Air Consumption CurvesFD2111 FD2122 FD2211 FD2222 FD2113 FD2213 FD2132 FD2232 FD2 All 1590 Stainless Steel FDA-Compliant PumpsFK2111 For 1590 Stainless Steel Sanitary PumpsFK2111 FK2122 FK2211 FK2222 FK2113 FK2213 FK2132 FK2232 TI8927b Air Motor Parts List Matrix Column SST Pump Mounting Hole Pattern 1590 FDAMaximum fluid working pressure Psi 0.8 MPa, 8 bar To find Pump Air Pressure FD3111 FD3122 FD3211 FD3222 FD3113 FD3213 FD3132 FD3232 FD3 All 2150 SST FDA-Compliant PumpsFK3111 For 2150 Stainless Steel Sanitary PumpsFK3111 FK3122 FK3211 FK3222 FK3113 FK3213 FK3132 FK3232 110 103 Air Motor Parts List Matrix Column 113 510490 CLAMP, sanitary 2150 FDA Gpm 568 lpm Fluid Graco Standard Pump Warranty Extended Product WarrantyGraco Warranties Graco Information

FD2 1590 specifications

The Hitachi FD2 1590 is a noteworthy addition to the world of industrial and commercial machinery, designed to meet the evolving needs of businesses that require robust, dependable equipment for their heavy-duty operations. This machine is engineered for versatility, equipped to handle a variety of tasks efficiently.

One of the standout features of the Hitachi FD2 1590 is its powerful engine, which delivers impressive torque and horsepower. This allows the equipment to perform effectively in challenging conditions, providing the necessary force to tackle tough terrains and heavy loads. The fuel efficiency of the engine also contributes to reduced operational costs, making it a cost-effective solution for businesses.

The FD2 1590 embraces advanced technologies that enhance its operational capabilities. Among these technologies are sophisticated hydraulic systems that allow for smooth operation and precise control. This ensures that the machine can carry out tasks such as lifting, moving, and digging with greater accuracy and ease. The hydraulic system is designed for quick response times, enabling operators to navigate their workload efficiently.

Durability is a hallmark of the Hitachi FD2 1590, as it is constructed with high-quality materials that withstand the rigors of daily use. The robust frame and components are designed to resist wear and tear, minimizing maintenance needs and extending the lifespan of the equipment. This reliability is crucial for businesses that depend on their machinery for consistent performance.

Operator comfort and safety are also key considerations in the design of the FD2 1590. The operator's cabin is spacious and ergonomically designed, providing easy access to controls and excellent visibility of the work area. Safety features such as reinforced structures, emergency shut-off systems, and stability controls further enhance the protection of both the operator and the machine.

In terms of technological integration, the Hitachi FD2 1590 is compatible with various monitoring systems that streamline operations. These systems offer data analytics capabilities that allow operators to track performance metrics, fuel consumption, and maintenance schedules in real-time. This connectivity not only optimizes machine efficiency but also informs better decision-making for operational improvements.

In summary, the Hitachi FD2 1590 is a powerful, durable, and technologically advanced machine, ideal for heavy-duty applications. Its performance capabilities, alongside its operator-friendly design and safety features, make it a valuable asset for any business looking to enhance its operational efficiency.