Hitachi FD2 1590 important safety instructions Performance Chart, To find Pump Air Pressure

Page 41

Performance Chart - 1590

Test Conditions: Pump tested in water with inlet submerged

Fluid Pressure Curves

Performance Chart - 1590

A

at 120 psi (0.7 MPa, 7 bar) operating air pressure

 

140

PressureOutlet bar)(MPa,psi

(0.96, 9.6)

(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and

(0.41, 4.1)

B

at 100 psi (0.7 MPa, 7 bar) operating air pressure

 

120

C

at 70 psi (0.48 MPa, 4.8 bar) operating air pressure

 

(0.84, 8.4)

D

at 40 psi (0.28 MPa, 2.8 bar) operating air pressure

 

100

 

(0.7, 7)

 

 

 

80

To find Fluid Outlet Pressure

 

(0.55, 5.5)

 

60

 

 

Fluid

operating air pressure (psi/MPa/bar):

40

 

 

 

 

 

 

 

(0.28, 2.8)

1.

Locate fluid flow rate along bottom of chart.

 

20

2.

Follow vertical line up to intersection with selected

 

(0.14, 1.4)

 

0

 

operating air pressure curve.

 

 

 

 

3.

Follow left to scale to read fluid outlet pressure.

 

 

 

 

Air Consumption Curves

 

 

 

A at 120 psi (0.7 MPa, 7 bar) operating air pressure

 

 

140

B at 100 psi (0.7 MPa, 7 bar) operating air pressure

 

 

(0.96, 9.6)

 

 

120

C at 70 psi (0.48 MPa, 4.8 bar) operating air pres-

 

 

ConsumptionAir

(mscfm

(0.84, 8.4)

sure

 

 

100

D at 40 psi (0.28 MPa, 2.8 bar) operating air pres-

 

 

(0.7, 7)

 

/min)

80

sure

 

 

 

 

 

 

(0.55, 5.5)

 

 

 

 

 

 

 

 

3

60

To find Pump Air Pressure

 

 

(0.41, 4.1)

 

 

40

 

3

 

 

 

(scfm or m

/min) at a specific fluid flow (gpm/lpm)

 

 

(0.28, 2.8)

 

 

 

20

and operating air pressure (psi/MPa/bar):

 

 

 

 

(0.14, 1.4)

1. Locate fluid flow rate along bottom of chart.

 

 

0

2.Read vertical line up to intersection with selected operating air pressure.

3.Follow left to scale to read air consumption.

20

40

60

80

(75)

(151)

(227)

(302)

Fluid Flow

gpm (lpm)

20

40

60

80

(75)

(151)

(227)

(302)

Fluid Flow

gpm (lpm)

100120

(378)(454)

TI8738A

TI8742A

100 120

(378)(454)

TI8739A

TI8742A

311879F

41

Image 41
Contents II 2 G Instructions Parts ListImportant Safety Instructions Contents Certificate of Conformance Fire and Explosion Hazard Toxic Fluid or Fumes Hazard General Information InstallationTightening Clamps Before First Use GroundingFluid Suction Line MountingsAir Line Key Fluid Outlet LineChanging the Orientation of the Fluid Inlet Outlet Ports Venting Exhaust Air Air Exhaust VentilationStarting and Adjusting the Pump Pressure Relief ProcedureOperation Sanitize the Pump Before First UseOperation Preventive Maintenance Schedule MaintenanceLubrication FlushingProblem Cause Solution TroubleshootingTroubleshooting Repairing the Air Valve ServiceDisassembly ReassemblyTorque to 52-60 in-lb Tools Required Ball Check Valve RepairStandard Diaphragm Repair Reassembly Cutaway view, with diaphragms in place Heavy-Duty Diaphragm Repair 24 104 403 106 101 Bearing and Air Gasket Removal Detail of air valve bearings FD1111 FD1122 FD1211 FD1222 FD1113 FD1213 FD1132 FD1232 Pump MatrixFDA-Compliant Stainless Steel Sanitary Pumps For 1040 Stainless Steel Sanitary Pumps Repair Kit MatrixFK1111 FK1111 FK1122 FK1211 FK1222 FK1113 FK1213 FK1132 FK1232Detail of Heavy-Duty Diaphragm PartsAir Motor Parts List Matrix Column Seat Parts List Matrix Column Fluid Section Parts List Matrix ColumnBall Parts List Matrix Column Diaphragm Parts List Matrix Column1040 FDA Dimensional DrawingPump Mounting Wetted materials on all models SST Technical DataFluid Pressure Curves Performance ChartTo find Fluid Outlet Pressure Air Consumption CurvesFD2 All 1590 Stainless Steel FDA-Compliant Pumps FD2111 FD2122 FD2211 FD2222 FD2113 FD2213 FD2132 FD2232FK2111 FK2122 FK2211 FK2222 FK2113 FK2213 FK2132 FK2232 For 1590 Stainless Steel Sanitary PumpsFK2111 TI8927b Air Motor Parts List Matrix Column SST 1590 FDA Pump Mounting Hole PatternMaximum fluid working pressure Psi 0.8 MPa, 8 bar To find Pump Air Pressure FD3 All 2150 SST FDA-Compliant Pumps FD3111 FD3122 FD3211 FD3222 FD3113 FD3213 FD3132 FD3232FK3111 FK3122 FK3211 FK3222 FK3113 FK3213 FK3132 FK3232 For 2150 Stainless Steel Sanitary PumpsFK3111 110 103 Air Motor Parts List Matrix Column 113 510490 CLAMP, sanitary 2150 FDA Gpm 568 lpm Fluid Extended Product Warranty Graco Standard Pump WarrantyGraco Warranties Graco Information

FD2 1590 specifications

The Hitachi FD2 1590 is a noteworthy addition to the world of industrial and commercial machinery, designed to meet the evolving needs of businesses that require robust, dependable equipment for their heavy-duty operations. This machine is engineered for versatility, equipped to handle a variety of tasks efficiently.

One of the standout features of the Hitachi FD2 1590 is its powerful engine, which delivers impressive torque and horsepower. This allows the equipment to perform effectively in challenging conditions, providing the necessary force to tackle tough terrains and heavy loads. The fuel efficiency of the engine also contributes to reduced operational costs, making it a cost-effective solution for businesses.

The FD2 1590 embraces advanced technologies that enhance its operational capabilities. Among these technologies are sophisticated hydraulic systems that allow for smooth operation and precise control. This ensures that the machine can carry out tasks such as lifting, moving, and digging with greater accuracy and ease. The hydraulic system is designed for quick response times, enabling operators to navigate their workload efficiently.

Durability is a hallmark of the Hitachi FD2 1590, as it is constructed with high-quality materials that withstand the rigors of daily use. The robust frame and components are designed to resist wear and tear, minimizing maintenance needs and extending the lifespan of the equipment. This reliability is crucial for businesses that depend on their machinery for consistent performance.

Operator comfort and safety are also key considerations in the design of the FD2 1590. The operator's cabin is spacious and ergonomically designed, providing easy access to controls and excellent visibility of the work area. Safety features such as reinforced structures, emergency shut-off systems, and stability controls further enhance the protection of both the operator and the machine.

In terms of technological integration, the Hitachi FD2 1590 is compatible with various monitoring systems that streamline operations. These systems offer data analytics capabilities that allow operators to track performance metrics, fuel consumption, and maintenance schedules in real-time. This connectivity not only optimizes machine efficiency but also informs better decision-making for operational improvements.

In summary, the Hitachi FD2 1590 is a powerful, durable, and technologically advanced machine, ideal for heavy-duty applications. Its performance capabilities, alongside its operator-friendly design and safety features, make it a valuable asset for any business looking to enhance its operational efficiency.