Franklin TS-TPI manual Pump N Menus, Type Read only Group Read only Address Read only

Page 21

PUMP N Menu(s)

NAME (user entry)

TYPE “READ ONLY”

GROUP “READ ONLY”

ADDRESS “READ ONLY”

TANK (user entry)

HEIGHT (user entry)

NAME (user entry)

NOTE In the following examples, “N” represents any pump

Description of Steps:

number - 1, 2, 3 and so on.

The PUMP N menu displays six subsequent

PUMP N

fields, including TANK and HEIGHT (scroll

NAME

down)...

 

1) Press the M1 key to display the NAME

M1

PUMP N user entry field...

 

TYPE

M2

(MORE)

GROUP ADDRESS

M3

 

M4

 

 

 

The default name of “PUMP 1 is displayed...

NAME PUMP N

A ... M

 

PUMP1

BACKSPACE

2)Press the M4 key to backspace and erase the “PUMP 1” default name.

M1

M2

M3

M4

3)Use the keypad to enter a unique name for each pump, up to 8 characters long (See NOTE below).

Remember:

Use the SHIFT key to change the keypad for A...M to N...Z and to (numeric) 1-9, 0, ., =/-, and SPACE (a blank space)

4)Press the ENTER key to accept the data entry.

The display returns to the PUMP N menu. Repeat the user entry steps for each pump.

4

NOTE The Pump name can be up to 8 alpha/numeric characters. This alias is used throughout the system in the display and reports. An example name would be UNLEADED. The name is not automatically updated or over-written by an AUTO CFG operation.

Page 4-4

TS-TPI SETUP PROGRAMMING

 

TS-TPI Installation and Wiring Guide

Image 21
Contents TS-TPITurbine Pump Interface Installation and Wiring Guide Intelligent Controls INC Table of Contents Graphic Symbol Conventions SafetySafety Safety Overview TS-TPI Installation & WiringTPI Board TPI Board TPI Board TPC Stand Alone TPI Stand Alone TS-TPI TPI Configuration Switch Tank SENTINEL/TS-TPI Interface Monitor, Record and Reset Pump Controller FaultsTS-LS300 report, Leak Test Initiating Capabilities Diagnostic Operations TS-TPI Menu TS-TPI Setup ProgrammingTS-TPI Pump Menus Auto CFGAuto CFG, PUMP1, PUMP2 Number of Pumps Menu NO.PUMPS Read onlyRead only Note Type Read only Group Read only Address Read only Pump N MenusSC STP-SC SCI STP-SCI Sciii STP-SCIII VFC IST-VFC Type Read onlyPress the Cancel key to return to the Pump Group Group Menu Notes TPI Group Menu+/- Space ReserveServe Exiting Setup ModeLN Line Test Menu Note TPI and Line Leak TestingLN Line leak Tests Menu ST DAY SundayTH DAY Last DAY GPH Line Test Time NFail OG Fault OGLine Test Fail Output Group Line Test Fail Output Group NOverview TS-TPI Data and ReportsTPI Status Display Notes Tank Sentinel Keypad & Menu NavigationDown Space Display MenuPump Display examples Diag Menu TPI Diagnostic Function NotesReset Menu Calibrt Menu Calibration ProcedurePump Controller Status Report RUN Mode How to print the reportSystem Setup Report Additions TPI/Pump Controller Setup Select Setup Report Shift 1ST DAY Daily Monday 30TH DAY Last DAY Sunday Reports MenuReports Schedule Menu Troubleshooting IST-VFC STP-SCIII Inside Back Cover

TS-TPI specifications

The Franklin TS-TPI (Total Pipeline Inspection) is a cutting-edge tool designed to revolutionize pipeline inspections across various industries, including oil and gas, water, and wastewater management. This advanced technology enables operators to assess the integrity of pipeline systems efficiently and accurately, ensuring safety and compliance with regulatory standards.

One of the main features of the Franklin TS-TPI is its ability to perform comprehensive inspections using a variety of sensors and imaging technologies. It incorporates high-definition cameras that provide detailed visual representations of the pipeline's interior, allowing for real-time monitoring and evaluation. Additionally, it leverages ultrasonic and electromagnetic sensors to detect anomalies such as corrosion, leaks, and structural defects—critical factors that could lead to catastrophic failures if left unaddressed.

The Franklin TS-TPI employs innovative robotics and autonomous capabilities, enabling it to navigate complex pipeline systems with ease. Its modular design allows for customization based on the specific needs of a pipeline, with attachments that can be added or removed as required. This flexibility not only enhances its functionality but also extends the lifespan of the equipment by allowing operators to upgrade sensors and technology as new advancements emerge.

Another notable characteristic of the Franklin TS-TPI is its data management capabilities. The system collects vast amounts of inspection data, which can be analyzed using advanced software solutions. This technology provides operators with insights into the condition of their pipelines, helping them make informed decisions regarding maintenance and repairs. Predictive analytics can also be applied to assess the likelihood of future failures, allowing for proactive actions to prevent costly disruptions.

The Franklin TS-TPI's user-friendly interface and powerful reporting tools enhance its usability, making it accessible to a wide range of professionals. With easy integration into existing pipeline management systems, it can streamline operations, improve response times to potential issues, and help operators meet compliance and safety standards more effectively.

Overall, the Franklin TS-TPI represents a significant leap forward in pipeline inspection technology. Its combination of advanced imaging, sensor technology, robotics, and data analytics creates a robust solution that addresses the challenges faced by industries reliant on pipeline infrastructure. By ensuring the integrity and operational efficiency of pipelines, the Franklin TS-TPI not only protects valuable resources but also promotes environmental sustainability and public safety.