Franklin TS-TPI manual Reserve, +/- Space

Page 26

MODE “User Entry” Note

(Mode functions are not available with STP-SC, STP-SCIII or IST-VFC)

MODE allows the operator to select which Level Management mode to use for a particular group. The choices are NONE, LEVELING, and PRIORITY:

Selecting NONE means NO level management mode for the Group (no Reserve to enter). This is used for Groups with TPCs configured as stand alone controllers.

Selecting the LEVELING mode seeks to maintain an equal level of fuel in each tank by placing pump controllers associated with the tank containing the most amount of fuel to priority. This will force the pump with the highest level of fuel to activate when the dispenser switch is activated (no Reserve to enter).

Selecting the PRIORITY option enables a mode that seeks to drain one tank before the other tank(s). Only when the PRIORITY mode is selected the RESERVE menu will appear.

Reserve Configuration Note

RESERVE is set after choosing the PRIORITY MODE. This entry sets the reserve level of fuel remain- ing in the tank. The programming defines this percentage as an “empty” tank and is programmed in % full.

For example, setting the Reserve to 20% means, when the tank is 20% full it is considered “empty”. This will trigger two events; the ATG will change the priority of the pumps so a pump starts pumping fuel from a different tank and lowers the priority of the pump in the tank that has reached its Reserve. This helps to prevent the faults Dry Run and PUMP in Water. If all tanks reach the Reserve level the pumps will function in leveling mode.

Mode Type and Reserve Note

The STND ALON “type” designated the GROUP as a Stand Alone Group without any Master/Slave associations. Members of the group consists of only one pump and one controller. The menus MODE and RESERVE are not enabled for Stand Alone TYPE. This completes Setup Programming for this type.

The MAST SLAV ‘type’ designates the GROUP as a Master/Slave configuration. The group consists of more than one pump controller. This “type” is further defined by the kind of Level Management “mode” either Leveling or Priority. If Priority is selected, the user is required to enter a value for

RESERVE.

MODE (user entry)

Description of Steps:

Here is the MODE GROUP 2 user entry field display. NONE is the default setting...

1)Use the UP/DOWN keys to change the default mode and scroll through the other modes - LEVELING and PRIORITY...

2)Press the ENTER key to accept data entry. This entry returns the display to the GROUP N menu.

If PRIORITY is selected, Proceed to the RESERVE menu, which is described next...

MODE GROUP 2

 

(UP/DN)

NONE

 

 

 

 

 

 

 

 

G T

 

K

X

 

UP

 

DOWN

 

+/- SPACE

ENTER

MODE GROUP 2

(UP/DN)

PRIORITY

 

GROUP 2

TYPE MODE RESERVE

TS-TPI SETUP PROGRAMMING

Page 4-9

TS-TPI Installation and Wiring Guide

 

4

Image 26
Contents TS-TPITurbine Pump Interface Installation and Wiring Guide Intelligent Controls INC Table of Contents Safety Graphic Symbol ConventionsSafety Safety TS-TPI Installation & Wiring OverviewTPI Board TPI Board TPI Board TPC Stand Alone TPI Stand Alone TS-TPI TPI Configuration Switch Monitor, Record and Reset Pump Controller Faults Tank SENTINEL/TS-TPI InterfaceTS-LS300 report, Leak Test Initiating Capabilities Diagnostic Operations TS-TPI Setup Programming TS-TPI MenuAuto CFG, PUMP1, PUMP2 TS-TPI Pump MenusAuto CFG Read only Note Number of Pumps MenuNO.PUMPS Read only Pump N Menus Type Read only Group Read only Address Read onlyType Read only SC STP-SC SCI STP-SCI Sciii STP-SCIII VFC IST-VFCPress the Cancel key to return to the Pump Group TPI Group Menu Group Menu NotesReserve +/- SpaceExiting Setup Mode ServeTPI and Line Leak Testing LN Line Test Menu NoteLN Line leak Tests Menu TH DAY Last DAY SundayST DAY GPH Line Test Time NLine Test Fail Output Group Fault OGFail OG Line Test Fail Output Group NTPI Status Display Notes TS-TPI Data and ReportsOverview Tank Sentinel Keypad & Menu NavigationDisplay Menu Down SpacePump Display examples TPI Diagnostic Function Notes Diag MenuReset Menu Calibration Procedure Calibrt MenuPump Controller Status Report How to print the report RUN ModeSystem Setup Report Additions TPI/Pump Controller Setup Select Setup Report Reports Menu Shift 1ST DAY Daily Monday 30TH DAY Last DAY SundayReports Schedule Menu Troubleshooting IST-VFC STP-SCIII Inside Back Cover

TS-TPI specifications

The Franklin TS-TPI (Total Pipeline Inspection) is a cutting-edge tool designed to revolutionize pipeline inspections across various industries, including oil and gas, water, and wastewater management. This advanced technology enables operators to assess the integrity of pipeline systems efficiently and accurately, ensuring safety and compliance with regulatory standards.

One of the main features of the Franklin TS-TPI is its ability to perform comprehensive inspections using a variety of sensors and imaging technologies. It incorporates high-definition cameras that provide detailed visual representations of the pipeline's interior, allowing for real-time monitoring and evaluation. Additionally, it leverages ultrasonic and electromagnetic sensors to detect anomalies such as corrosion, leaks, and structural defects—critical factors that could lead to catastrophic failures if left unaddressed.

The Franklin TS-TPI employs innovative robotics and autonomous capabilities, enabling it to navigate complex pipeline systems with ease. Its modular design allows for customization based on the specific needs of a pipeline, with attachments that can be added or removed as required. This flexibility not only enhances its functionality but also extends the lifespan of the equipment by allowing operators to upgrade sensors and technology as new advancements emerge.

Another notable characteristic of the Franklin TS-TPI is its data management capabilities. The system collects vast amounts of inspection data, which can be analyzed using advanced software solutions. This technology provides operators with insights into the condition of their pipelines, helping them make informed decisions regarding maintenance and repairs. Predictive analytics can also be applied to assess the likelihood of future failures, allowing for proactive actions to prevent costly disruptions.

The Franklin TS-TPI's user-friendly interface and powerful reporting tools enhance its usability, making it accessible to a wide range of professionals. With easy integration into existing pipeline management systems, it can streamline operations, improve response times to potential issues, and help operators meet compliance and safety standards more effectively.

Overall, the Franklin TS-TPI represents a significant leap forward in pipeline inspection technology. Its combination of advanced imaging, sensor technology, robotics, and data analytics creates a robust solution that addresses the challenges faced by industries reliant on pipeline infrastructure. By ensuring the integrity and operational efficiency of pipelines, the Franklin TS-TPI not only protects valuable resources but also promotes environmental sustainability and public safety.