Franklin TS-TPI manual Reports Menu, Shift 1ST DAY Daily Monday 30TH DAY Last DAY Sunday

Page 42

7

LINE Reports SETUP

Reports Menu

H

U

 

MENU

½ Press this key in the highlighted

 

7

sequence shown below

SELECT MENU OPTION

SETUP UPGRADE LANGUAGE DATALOG

M1

M2

M3

M4

SETUP MENU

 

(MORE)

EXIT

SYSTEM

TANKS

PROBES

Press the DOWN ▼ key...

SETUP MENU

(MORE)

PRODUCTS MANIFOLDS* REPORTS

LK TSTS

Use this menu to program reports to print or FAX automatically on a schedule (faxing requires an optional Fax/Modem device). See Tank Sentinel Setup Programming Guide Chapters 1, 10, 11 and 12 about Tank and Line Test Reports & Scheduling.

See TABLE 7.1 – The SHIFT selection allows 2 or 3 scheduled reports to print or Fax per day

...only one report will print if two report-times are duplicated / identical.

M1

M2

M3

M4

The asterisked (*) menus are hardware or software dependent and may or may not appear.

Press the DOWN ▼ key until the Line Comp, Line Diag, Line Hist and Line Test menus are shown.

REPORT SCHEDULE

(MORE)

LINE COMP * LINE DIAG LINE HIST *

LINE TEST *

TABLE 7.1 Typical Report Schedule

NONE (no schedule)

SHIFT

1ST DAY

DAILY

:

MONDAY

30TH DAY

:

LAST DAY

SUNDAY

(Feb. does not have 30 days)

Push UP/DOWN ▲ ▼ keys to show more menus or menu selections.

To access menus, press the corrsponding (M) key below each menu name.

— Continued on next page —

TABLE 7.2 24 Hour Time Input Format

HH:MM:SS

00:00:00 = midnight

22:00:00 = 10 pm + 12 ( hours )

( add 12 hours to pm times starting at

1 pm to 11:59 pm )

02:05:00 = 2:05 am

LINE REPORTS SETUP

Page 7-1

TS-TPI Installation and Wiring Guide

 

7

Image 42
Contents TS-TPITurbine Pump Interface Installation and Wiring Guide Intelligent Controls INC Table of Contents Safety Graphic Symbol ConventionsSafety Safety TS-TPI Installation & Wiring OverviewTPI Board TPI Board TPI Board TPC Stand Alone TPI Stand Alone TS-TPI TPI Configuration Switch Monitor, Record and Reset Pump Controller Faults Tank SENTINEL/TS-TPI InterfaceTS-LS300 report, Leak Test Initiating Capabilities Diagnostic Operations TS-TPI Setup Programming TS-TPI MenuTS-TPI Pump Menus Auto CFGAuto CFG, PUMP1, PUMP2 Number of Pumps Menu NO.PUMPS Read onlyRead only Note Pump N Menus Type Read only Group Read only Address Read onlyType Read only SC STP-SC SCI STP-SCI Sciii STP-SCIII VFC IST-VFCPress the Cancel key to return to the Pump Group TPI Group Menu Group Menu NotesReserve +/- SpaceExiting Setup Mode ServeTPI and Line Leak Testing LN Line Test Menu NoteLN Line leak Tests Menu TH DAY Last DAY SundayST DAY GPH Line Test Time NLine Test Fail Output Group Fault OGFail OG Line Test Fail Output Group NTPI Status Display Notes TS-TPI Data and ReportsOverview Tank Sentinel Keypad & Menu NavigationDisplay Menu Down SpacePump Display examples TPI Diagnostic Function Notes Diag MenuReset Menu Calibration Procedure Calibrt MenuPump Controller Status Report How to print the report RUN ModeSystem Setup Report Additions TPI/Pump Controller Setup Select Setup Report Reports Menu Shift 1ST DAY Daily Monday 30TH DAY Last DAY SundayReports Schedule Menu Troubleshooting IST-VFC STP-SCIII Inside Back Cover

TS-TPI specifications

The Franklin TS-TPI (Total Pipeline Inspection) is a cutting-edge tool designed to revolutionize pipeline inspections across various industries, including oil and gas, water, and wastewater management. This advanced technology enables operators to assess the integrity of pipeline systems efficiently and accurately, ensuring safety and compliance with regulatory standards.

One of the main features of the Franklin TS-TPI is its ability to perform comprehensive inspections using a variety of sensors and imaging technologies. It incorporates high-definition cameras that provide detailed visual representations of the pipeline's interior, allowing for real-time monitoring and evaluation. Additionally, it leverages ultrasonic and electromagnetic sensors to detect anomalies such as corrosion, leaks, and structural defects—critical factors that could lead to catastrophic failures if left unaddressed.

The Franklin TS-TPI employs innovative robotics and autonomous capabilities, enabling it to navigate complex pipeline systems with ease. Its modular design allows for customization based on the specific needs of a pipeline, with attachments that can be added or removed as required. This flexibility not only enhances its functionality but also extends the lifespan of the equipment by allowing operators to upgrade sensors and technology as new advancements emerge.

Another notable characteristic of the Franklin TS-TPI is its data management capabilities. The system collects vast amounts of inspection data, which can be analyzed using advanced software solutions. This technology provides operators with insights into the condition of their pipelines, helping them make informed decisions regarding maintenance and repairs. Predictive analytics can also be applied to assess the likelihood of future failures, allowing for proactive actions to prevent costly disruptions.

The Franklin TS-TPI's user-friendly interface and powerful reporting tools enhance its usability, making it accessible to a wide range of professionals. With easy integration into existing pipeline management systems, it can streamline operations, improve response times to potential issues, and help operators meet compliance and safety standards more effectively.

Overall, the Franklin TS-TPI represents a significant leap forward in pipeline inspection technology. Its combination of advanced imaging, sensor technology, robotics, and data analytics creates a robust solution that addresses the challenges faced by industries reliant on pipeline infrastructure. By ensuring the integrity and operational efficiency of pipelines, the Franklin TS-TPI not only protects valuable resources but also promotes environmental sustainability and public safety.