Graco 256200 Performance Chart, Calculate Fluid Outlet Pressure black curves

Page 28

Technical Data

Performance Chart

Calculate Fluid Outlet Pressure (black curves)

To calculate fluid outlet pressure (MPa/bar/psi) at a specific fluid flow (lpm/gpm) and operating air pressure (MPa/bar/psi), use the following instructions and pump data chart.

1.Locate desired fluid flow along bottom of chart.

2.Follow vertical line up to intersection with selected air pressure curve (black). Follow horizontally left to read fluid outlet pres- sure.

Calculate Pump Air Consumption (gray curves)

To calculate pump air consumption (m3/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (MPa/bar/psi), use the following instructions and pump data chart.

1.Locate desired fluid flow along bottom of chart.

2.Follow vertical line up to intersection with selected air pressure curve (gray). Follow horizontally right to read air consumption.

Key:

 

 

 

 

 

 

 

 

 

 

A 180 psi (1.2 MPA, 12.4 bar)

 

 

 

 

 

 

 

 

 

B 100 psi (0.7 MPA, 7 bar)

 

 

 

 

 

 

 

 

 

C 70 psi (0.5 MPa, 7.8 bar)

 

 

 

 

 

 

 

 

 

D 40 psi (0.3 MPa, 2.8 bar)

 

 

 

 

 

 

 

 

 

 

350

 

 

 

 

 

 

 

24

 

 

(24.5, 245)

 

 

 

 

 

 

 

(0.672)

 

PSI (MPa, bar)

300

 

 

 

 

 

 

 

20

Air

(21, 210)

 

 

 

 

A

 

 

Consumption

 

 

 

 

 

 

(0.560)

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(17.5, 175)

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

(0.448)

 

 

B

 

 

 

 

 

in

(14, 140)

 

 

 

 

A

12

in

Pressure

 

 

 

 

 

 

SCFM

150

 

 

 

 

 

 

 

(0.336)

 

C

 

 

 

 

 

 

(10.5, 105)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(m

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

3

Outlet

100

 

 

 

 

 

 

 

/min)

 

 

 

 

 

 

 

(0.224)

(7, 70)

D

 

 

 

B

 

 

4

 

50

 

 

 

 

 

 

 

D

 

 

 

 

 

 

(0.112)

 

 

(3.5, 35)

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

1

1.5

2

2.5

3

3.5

4

 

 

0

0.5

 

 

 

(1.9)

(3.8)

(5.7)

(7.6)

(9.5)

(11.4)

(13.2) (15.1)

 

 

 

 

Fluid Flow in gpm (lpm)

 

 

 

 

28

312766N

Image 28
Contents Ratio Transfer Pump Contents Toxic Fluid or Fumes Hazard Equipment Misuse Hazard Isocyanate Hazard Moisture Sensitivity of IsocyanatesKeep Components a and B Separate Foam Self-IgnitionChanging Materials Typical Installation Typical Installation without CirculationTypical Installation with Circulation Typical Installation with CirculationTypical Installation for Lubrication Applications Typical Installation for Lubrication ApplicationsInstallation System AccessoriesSetup Grounding Operation Pressure Relief ProcedureFlush Pump Before Use Daily Startup Daily ShutdownRepair Air Motor DisassemblyBefore you start Air Motor Reassembly Pump Lower Disassembly Unscrew the piston cylinder 58 from the pump framePush down on the pump connecting rod Pump Lower Reassembly Series a and BTI21636a Troubleshooting Problem Cause SolutionParts T1 21 Ratio Transfer PumpPart Description Qty Accessories Grounding ClampAir Regulator and Gauge Dimensions Technical Data See Performance Chart onPerformance Chart Calculate Fluid Outlet Pressure black curvesTechnical Data 312766N Graco Standard Warranty Graco Information