Warnings

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the low- est rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See

Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts imme- diately.

MOVING PARTS HAZARD

Moving parts can pinch or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Dis- connect power or air supply.

4

312766N

Image 4
Contents Ratio Transfer Pump Contents Toxic Fluid or Fumes Hazard Equipment Misuse Hazard Isocyanate Hazard Moisture Sensitivity of IsocyanatesKeep Components a and B Separate Foam Self-IgnitionChanging Materials Typical Installation Typical Installation without CirculationTypical Installation with Circulation Typical Installation with CirculationTypical Installation for Lubrication Applications Typical Installation for Lubrication ApplicationsInstallation System AccessoriesSetup Grounding Operation Pressure Relief ProcedureFlush Pump Before Use Daily Startup Daily ShutdownRepair Air Motor DisassemblyBefore you start Air Motor Reassembly Pump Lower Disassembly Unscrew the piston cylinder 58 from the pump framePush down on the pump connecting rod Pump Lower Reassembly Series a and BTI21636a Troubleshooting Problem Cause SolutionParts T1 21 Ratio Transfer PumpPart Description Qty Accessories Grounding ClampAir Regulator and Gauge Dimensions Technical Data See Performance Chart onPerformance Chart Calculate Fluid Outlet Pressure black curvesTechnical Data 312766N Graco Standard Warranty Graco Information