Graco 256200 important safety instructions Typical Installation with Circulation

Page 8

Typical Installation

Typical Installation with Circulation

Key for FIG. 2.

AReactor Proportioner

BHeated Hose

CFluid Temperature Sensor (FTS)

DHeated Whip Hose

EFusion Spray Gun

FProportioner and Gun Air Supply Hose

K

A

N

B

GFeed Pump Air Supply Lines 3/8 in. (76 mm) ID min.

JFluid Supply Lines (217382)

KFeed Pumps

LAgitator

MDesiccant Dryer

NBleed Lines/Over Pressure Relief

PGun Fluid Manifold

G

M

K

F

J

D

EL

N

P

C*

ti11571a

* Shown exposed for clarity. Wrap with tape during operation.

FIG. 2: Typical Installation with Circulation

8

312766N

Image 8
Contents Ratio Transfer Pump Contents Toxic Fluid or Fumes Hazard Equipment Misuse Hazard Isocyanate Hazard Moisture Sensitivity of IsocyanatesChanging Materials Foam Self-IgnitionKeep Components a and B Separate Typical Installation Typical Installation without CirculationTypical Installation with Circulation Typical Installation with CirculationTypical Installation for Lubrication Applications Typical Installation for Lubrication ApplicationsInstallation System AccessoriesSetup Grounding Flush Pump Before Use Pressure Relief ProcedureOperation Daily Startup Daily ShutdownBefore you start Air Motor DisassemblyRepair Air Motor Reassembly Pump Lower Disassembly Unscrew the piston cylinder 58 from the pump framePush down on the pump connecting rod Pump Lower Reassembly Series a and BTI21636a Troubleshooting Problem Cause SolutionParts T1 21 Ratio Transfer PumpPart Description Qty Accessories Grounding ClampAir Regulator and Gauge Dimensions Technical Data See Performance Chart onPerformance Chart Calculate Fluid Outlet Pressure black curvesTechnical Data 312766N Graco Standard Warranty Graco Information