Harbor Freight Tools 92274 manual Pump Motor Runs, but does not discharge water

Page 11

B.Water level in pit may be too low (Switch has not yet activated). Add more water to pit.

C.Power Cord may not be making contact in electrical outlet. Check connec- tion.

D.Float may be obstructed. Make sure the Float is free and not rubbing against the pit wall or other obstruction.

3.Pump Motor Runs, but does not discharge water.

A.Check Valve (not included) may be installed backwards or is defective. Check to make sure it is installed properly and flapper in valve is free to move.

B.Discharge Pipe may be frozen or blocked. Check to see if Discharge Pipe passes through cold areas or is blocked.

C.Sump Pump may be airlocked. Check to see if air bleed hole is open.

D.Vertical lift is beyond Sump Pump’s capability. Maximum lift capability is 17 feet.

E.Inlet screen of Sump Pump is blocked, or Impeller is jammed. Remove Pump and clean inlet screen and Impeller.

4.Pump Motor runs and discharges water, but will not shut off.

A.Float is stuck in the “ON” position. Check to make sure Float is free to move up and down without interference.

B.Switch is not working. Have a qualified service technician replace Switch.

5.Pump Motor runs, but delivers small amount of water.

A.Vertical lift is approaching Sump Pump’s maximum lift capability. Maximum lift capability is 17 feet. Reduce height of vertical lift.

B.Inlet is partially blocked. Check to make sure inlet is clear of debris.

C.Discharge Pipe is partially blocked. Check Pipe for blockage.

D.Check Valve is not opening all the way. Check for defective or blocked Check Valve.

6.Circuit breaker trips or fuse blows when Sump Pump starts.

A.Breaker or fuse size is too small. A minimum 15 AMP breaker or fuse should be used.

B.Other major appliances are on the same circuit. Sump Pump should be on its own separate circuit.

C.Sump Pump is connected to an extension cord, or wiring is inadequate. DO NOT USE EXTENSION CORDS. Have a certified electrician check

for proper wiring.

D.Switch or Motor not working. Have a qualified service technician check Switch and Motor for proper operation.

SKU 92274

For technical questions, please call 1-800-444-3353.

PAGE 11

Image 11
Contents For technical questions, please call HP Pedestal Sump PumpUnpacking Product SpecificationsGeneral Safety Rules Save this ManualSKU For technical questions, please call Electrical SafetyPersonal Safety Work AreaTool USE and Care Grounded Tools Tools with Three Prong Plugs ServiceGrounding Figure a SymbologySee Figure C Specific Safety RulesSKU For technical questions, please call Figure D Assembly and Operating InstructionsPump Motor does not run TroubleshootingSee Figure D Pump Motor runs, but delivers small amount of water Circuit breaker trips or fuse blows when Sump Pump startsPump Motor Runs, but does not discharge water Pump Motor runs and discharges water, but will not shut offPlease Read the Following Carefully INSPECTION, MAINTENANCE, and CleaningDescription Qty Parts ListAssembly Diagram