Harbor Freight Tools 92274 manual INSPECTION, MAINTENANCE, and Cleaning

Page 12

INSPECTION, MAINTENANCE, AND CLEANING

1. WARNING! Make sure the Sump Pump is unplugged from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.

2.Before each use, inspect the general condition of the Sump Pump. Check for clogs throughout the system, misalignment or binding of moving parts, damaged electrical wiring, damaged or loose discharge pipes, and any other condition that may affect its safe operation. If abnormal noise or vibration occurs, have the problem corrected before further use. Do not use damaged equipment.

3.Every six months, pour an ounce of 30 weight oil into the hole near the top of the Support (21). A label next to the hole indicates where to add the oil.

4.The Motor is permanently lubricated and requires no additional lubrication.

5.If the Sump Pump is not in use due to dry conditions, etc., pour enough water into the pit to activate the Pump once every 3 months.

6.Periodically, check to make sure the pit is free from accumulated debris, rocks, and other objects that may damage the Sump Pump.

7.When cleaning, NEVER introduce water or any other liquid into the Motor Hous- ing.

8.In cold weather, when the Sump Pump is not in use, protect the interior of the Pump from freezing by draining the liquid and pumping a permanent type auto- mobile anti-freeze containing a rust inhibitor through the system. A 50% mixture with water is recommended. Be sure to flush the system with a neutralizing liquid prior to re-use of the unit.

9. CAUTION! All maintenance, service, or repairs not listed in this manual are only to be attempted by a qualified service technician.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

SKU 92274

For technical questions, please call 1-800-444-3353.

PAGE 12

Image 12
Contents HP Pedestal Sump Pump For technical questions, please callProduct Specifications General Safety RulesSave this Manual UnpackingElectrical Safety Personal SafetyWork Area SKU For technical questions, please callTool USE and Care Service GroundingGrounded Tools Tools with Three Prong Plugs Symbology Figure aSpecific Safety Rules See Figure CSKU For technical questions, please call Assembly and Operating Instructions Figure DTroubleshooting See Figure DPump Motor does not run Circuit breaker trips or fuse blows when Sump Pump starts Pump Motor Runs, but does not discharge waterPump Motor runs and discharges water, but will not shut off Pump Motor runs, but delivers small amount of waterINSPECTION, MAINTENANCE, and Cleaning Please Read the Following CarefullyParts List Description QtyAssembly Diagram