WARNING

INJECTION HAZARD

Spray from the gun/valve, leaks or ruptured components can inject fluid into your body and cause ex- tremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medi- cal attention.

DDo not point the gun/valve at anyone or at any part of the body.

DDo not put your hand or fingers over the spray tip/valve nozzle.

DDo not stop or deflect leaks with your hand, body, glove or rag.

DDo not “blow back” fluid; this is not an air spray system.

DAlways have the tip guard and the trigger guard on the gun/valve when spraying/dispensing.

DBe sure the gun/valve trigger safety operates before spraying/dispensing.

DLock the gun/valve trigger safety when you stop spraying/dispensing.

DFollow the Pressure Relief Procedure on page 8 if the spray tip clogs and before cleaning, checking or servicing the equipment.

DTighten all fluid connections before operating the equipment.

DCheck the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose.

MOVING PARTS HAZARD

Moving parts can pinch or amputate your fingers.

DKeep clear of all moving parts when starting or operating the pump.

DBefore checking or servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

307160 3

Image 3 Contents
Model 210313, Series D Instructions Parts ListSymbols Table of ContentsInjection Hazard Fire and Explosion Hazard General Information Grounding InstallationDrain Valve FiltersHydraulic Lines Drip PanKEY Pressure Relief Procedure OperationFlushing the Pump Check Valve Adjustment Starting and Adjusting the PumpMaintenance Corrosion ProtectionShutdown Problem Cause Solution TroubleshootingDisassembly See Fig ServiceDescription Qty PartsNpt outlet Npt inlet 48.1 1220 mm 23.2 585 mm Dimensions Mounting Hole LayoutPump Output Technical DataPump Performance Charts Pump Pressure DevelopedGraco Information Graco Standard Warranty