Hitachi 210313 manual Operation, Pressure Relief Procedure, Flushing the Pump

Page 8

Operation

Pressure Relief Procedure

WARNING

INJECTION HAZARD

Fluid under high pressure can be in- jected through the skin and cause seri- ous injury. To reduce the risk of an injury

from injection, splashing fluid, or moving parts, fol- low the Pressure Relief Procedure whenever you

DAre instructed to relieve the pressure

DStop spraying/dispensing

DCheck or service any of the system equipment

DInstall or clean the spray tips/nozzles

1.Engage the safety latch.

2.Shut off the power supply to the hydraulic motor.

3.Disengage the gun safety latch.

4.Hold a metal part of the gun firmly to the side of a grounded metal pail. Trigger to relieve pressure.

5.Open the fluid drain valve (required in your sys- tem) having a container ready to catch the drain- age. Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely, then clear the tip or hose.

CAUTION

When shutting down the hydraulic system, always shut off the hydraulic supply line shutoff valve (S) first, and then the return line shutoff valve (E). This is to prevent overpressurizing the motor or its seals. When starting the hydraulic system, open the return line shutoff valve first.

Flushing the Pump

Flush the pump before using it for the first time to remove the lightweight oil which is left in the pump after factory testing to protect it from corrosion. Be sure the solvent used is compatible with the fluid to be sprayed, and with the wetted parts of the pump. Refer to the Technical Data in the separate displacement pump manual for the wetted parts. Flush until clean solvent comes from the gun. In a circulating system, flush long enough to clean the entire system.

8307160

Image 8 Contents
Instructions Parts List Model 210313, Series DTable of Contents SymbolsInjection Hazard Fire and Explosion Hazard Installation General Information GroundingFilters Hydraulic LinesDrip Pan Drain ValveKEY Flushing the Pump Pressure Relief ProcedureOperation Starting and Adjusting the Pump Check Valve AdjustmentShutdown MaintenanceCorrosion Protection Troubleshooting Problem Cause SolutionService Disassembly See FigParts Description QtyDimensions Mounting Hole Layout Npt outlet Npt inlet 48.1 1220 mm 23.2 585 mmTechnical Data Pump Performance ChartsPump Pressure Developed Pump OutputGraco Standard Warranty Graco Information