Hitachi 210313 manual Installation, General Information Grounding

Page 5

Installation

General Information

NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor.

Grounding

WARNING

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE OR EXPLOSION HAZ- ARD on page 4.

DPump: Use a ground wire and clamp as shown in Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm@) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. Order part num- ber 237569 Grounding Clamp and Wire.

DFluid and hydraulic hoses: Use only grounded hoses with a maximum of 500 ft (150 m) combined hose length to ensure grounding continuity.

DHydraulic Power Supply: Follow the manufacturer’s recommendations.

DSpray gun: Ground through connection to a prop- erly grounded fluid hose and sprayer.

DObject being sprayed: Follow the local code.

DFluid supply container: Follow the local code.

DSolvent pails used when flushing: Follow the local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continu- ity.

DTo maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

Z

X

Y

W

06431

Fig. 1

307160 5

Image 5 Contents
Model 210313, Series D Instructions Parts ListSymbols Table of ContentsInjection Hazard Fire and Explosion Hazard General Information Grounding InstallationHydraulic Lines FiltersDrip Pan Drain ValveKEY Flushing the Pump Pressure Relief ProcedureOperation Check Valve Adjustment Starting and Adjusting the PumpShutdown MaintenanceCorrosion Protection Problem Cause Solution TroubleshootingDisassembly See Fig ServiceDescription Qty PartsNpt outlet Npt inlet 48.1 1220 mm 23.2 585 mm Dimensions Mounting Hole LayoutPump Performance Charts Technical DataPump Pressure Developed Pump OutputGraco Information Graco Standard Warranty