THINGS YOU NEED TO KNOW

WARNINGS:
This appliance must be installed by a qualified
electrician/competent person. Safety may be
impaired if installation is not carried out in
accordance with these instructions.
This appliance must be earthed.
Do not remove the screws from the earth tab
extending from the oven mains terminal block
(Fig. 6).
Before connecting the appliance make sure that
the voltage of your electricity supply is the same
as that indicated on the rating plate. This is
situated on the lower front frame of the appliance
upon opening the main cavity door. Alternatively
the rating plate may also be found on the back or
top of some models (where applicable).
Do not alter the electrical circuitry of this
appliance.
THINGS TO NOTE
This appliance is designed to be fitted in cabinets
of the recommended dimensions as shown in Fig.
2. If your cabinet interior dimension is between
565-570mm the oven may still be fitted. However
a minor modification to the cabinet will be
required.
The dimensions given provide adequate air
circulation around the unit within the cabinet,
ensuring compliance with BS EN60-335.
Enquiries regarding the installation of the cooker
point if required should be made to your Regional
Electricity Company to ensure compliance with
their regulations.
The cooker point should be within 2m of the
appliance to make it accessible to switch off the
appliance in case of an emergency.
To protect the hands wear gloves when lifting the
oven into its housing.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried out
before the appliance is connected to the mains supply
and re-checked after fitting.

GETTING THINGS READY

CHOICE OF ELECTRICAL CONNECTION
There are three possible ways to connect your
appliance. In each case the appliance should be
operated using at least 6mm² twin core and earth PVC
insulated multicore cable. Please choose from the
most appropriate after reading the descriptions:
a) By connecting the appliance to a cooker point having a
double pole isolating switch with at least 3mm contact
separation in all poles and neutral, and protected with
a fuse or miniature circuit breaker at your mains fuse
box.
b) By connecting the appliance together with a hob box
directly to a cooker point(s). Having a double pole
isolating switch with at least 3mm contact separation in
all poles and neutral.
c) If you wish to connect an oven and a hob to a cooker
point you can by connecting the oven and hob
separately to the cooker point. Oven and hob units
should be separately connected to a control panel. See
Fig. 1.
NOTE: It is good practice to:
Fit an Earth Leakage Circuit Breaker to your house
wiring.
Wire your appliance to the latest IEE regulations.
PREPARING CABINET FOR FITTING OVEN
Make sure the cabinet is the correct size for the
appliance to be fitted (Ref. Fig. 2).
If the size is between 565-570*mm, then the cabinet
should be modified so that at the screw fixing points
the recommended dimension of at least 560-565mm is
maintained. The modification should ideally be
localised to ensure that after screw fitment the oven is
securely fixed into position.
The cabinet must be stable and level by firmly securing
it to the wall or floor. If necessary, make arrangements
to ensure the shelf upon which the oven will rest is
level
When the appliance is installed ensure a minimum gap
of 2mm is maintained between the trim on the
bottomedge of the appliance and any corresponding
door/ panel underneath.
Subject to Regional Electricity Company
regulations if you wish to connect the oven
and hob to the power supply you may use one
of the following two methods:-
INSTALLATION INSTRUCTIONS
Fig. 1
7