Electrolux W 345 B/M, W 375 B, W 365 B, W 355 B/M manual Machine Controls, Trouble Shooting

Page 6

MACHINE CONTROLS

1

 

2 3

4

 

5

6

7

8

9

1- Scrubbing detergent flow adjustment push button

2- Suction on/off push button

3- Brush motor on/off push button

4- Run-time hour meter

5- Scrubbing detergent flow boost pump on/off push button

6- Recovery tank full warning indicator

7- Brush release push button

8- Battery condition voltmeter

9- Master key-switch

10- Drive function control

10

11- Switch for the speed selection

11

12- Scrubbing detergent tank emptying

12

hose

13- Handle height adjustment locking hand- 13

wheel

14

14- Drive motor on/off switch

15

15- Squeegee control lever

16

16- Recovery tank emptying hose

17

17- Squeegee

18- Brush pressure control hand-wheel

18

19- Squeegee pressure control

19

20- Squeegee rake angle control

20

21- Brush lift/lower pedal

21

 

4

TROUBLE SHOOTING

PROBLEM

POSSIBLE CAUSE

CHECK

 

 

 

 

 

 

Nothing works.

No power.

Is the battery plugged in.

 

 

Is the mains lead plugged in

 

 

and switched on.

 

 

Is the mains socket live.

 

 

 

No liquid supply to the

Is the tank empty.

Fill the tank.

brushes.

 

 

 

 

 

 

 

 

Are the brushes revolving and

Try this sequence.

 

the machine moving as well

 

 

 

 

as the flow control activated.

 

 

 

 

 

 

 

Is the tank filter blocked.

Remove and clean.

 

 

 

 

Are the solenoid valves

Remove and clean.

 

blocked.

 

 

 

 

 

 

 

Are the pipes blocked.

Flush through with clean hot

 

 

water.

 

 

 

Squeegee is not drying the

Blockage in hose.

Remove and flush through

floor well.

 

with water.

 

 

 

 

Worn sgueegee not sitting

Adjust pressure and rake.

 

fully on floor.

 

 

 

 

 

 

 

Torn tank lid gasket.

Replace

 

 

 

All indicators flashing when

Traction control not in neutral

Centre the traction control

key switched on.

position.

then switch the key on.

 

 

 

All 3 indicators of the battery

Traction drive electronics

Call Service Engineer. or

condition meter flashing.

faulty.

Replace P.C.B.

 

 

 

3 indicators of battery

Overload in electrical circuit.

Will reset when cooled

condition meter flashing in

 

down. Check motor currents

sequence

 

for overload, or tight

 

 

bearings etc.

 

 

 

 

 

 

 

 

 

 

 

21

 

Image 6
Contents Manual for USE and Maintenance Index Optionals IntroductionUnpacking Optionals Technical Specification ModelsTrouble Shooting Machine ControlsSafety and Faults Preparation for USEPreparation for USE Maintenance Maintenance Preparation for USE 345-355Preparation for USE Changing Brushes Brushes are now loaded onto the machine OFF Scrubbing and Drying OperationTravel Direction Floor Level Scrubbing and Drying Operation