Everpure ENVI-RO Cartridge Installation and Activation, Recovery adjustment

Page 5

Cartridge Installation and Activation

1.Remove the outer shrink-wrap and protective cap from the 2SR-BW & MR-600 RO cartridges. Position a bucket under the 2SR -BW cartridge head. Slowly open the Inlet shut-off valve. Apply power to the system by plugging the power cord into the receptacle. Within moments, the display water should illuminate and the system will go into PRESSURIZE mode. Once a solid flow of water has been established, flush 1 gallon. Unplug power cord. Empty bucket.

2.Install 2SR-BW cartridge. Align the lugs on the new cartridge with the slots in the head. Holding the head and cartridge firmly, press the cartridge upward into the head fully, and then turn the cartridge to the right until it stops.

3.Disconnect 3/8" OD line from 2SR-BW to Booster Pump inlet at Booster Pump. Route line into bucket and secure. Plug-in power cord. Once a solid flow of water has been established, flush 1 gallon. Unplug power cord. Re-connect 3/8" OD line to Booster Pump inlet. Empty bucket.

4.Route a blue line from the 3/8" storage tank drain valve to drain temporarily. Open storage tank drain valve.

5.Install MR-600 cartridge. Align the lugs on the new cartridge with the slots in the head. Holding the head and cartridge firmly, press the cartridge upward into the head fully, and then turn the cartridge to the right until it stops.

6.Plug-in power cord. Once a solid flow of water has been established, flush 5 gallons from storage tank drain (about 10 minutes). Unplug power cord.

WARNING Do not use this product water! It may contain a preservative solution from the RO cartridge and should not be consumed!

recovery adjustment

1.Measure the raw water TDS. Refer to Table 1 on page 6. Find the TDS range in the column labeled “Raw Water TDS” that corresponds to your TDS measurement. Read across that row to determine maximum recovery, permeate to reject ratio and permeate/reject volumes.

2.Using 2 - 32 oz. or 1,000 ml graduated containers, apply power to the system and collect the permeate flow (from storage tank drain valve) in one container and the reject (WASTE) flow in the second container. Compare the volumes collected to the data shown in the table. Adjust the reject needle valve to increase or decrease the flow. Empty the containers and collect additional samples.

3.Once the ratio of Permeate-to-Reject closely matches the data in Table 1, the Reject Only volume requires measurement. Using only 1 graduated cylinder, collect the reject flow for 1 minute.

NOTE: Reject volume in 1 minute may exceed 32 oz./1,000 ml. If so, use a larger container, or collect samples in multiple containers and add all collected volumes together.

4.Unplug power cord. Close storage tank drain valve.

5.Return to page 6, Table 2. Find the volume range in the column labeled “Reject Volume per Minute” that corresponds to the volume collected in Step 4. Read across that row to identify the correct capillary tube combination.

6.Locate the correct capillary tubes from the parts kit. Remove the 2 - 1/4"OD tubes from the upper Y-connector. Insert the capillary tubes into each line and re-assemble to the Y-connector.

NOTE: In some cases, the capillary tube requires trimming. Use a SHARP utility knife to cut the tube cleanly without tearing or crushing the tube.

7.Remove Reject Needle valve assembly and reconnect 3/8" tube. Plug-in power cord. Allow system to run and fill tank. This will take 5-10 minutes.

8.Refer to Table 2 again. Under the column labeled “Flush Time in Seconds”, find the value that corresponds to the Raw Water TDS. Enter this value in the controller under “FLUSH TIME X1”. Adjust “FLUSH INT X2” to 1.5 Hours.

Figure 5. RO Reject Flow Control Assembly

Capillary

Not Trimmed FLOW

TUBECONTROL

Capillary

Trimmed FLOW

TUBE CONTROL

5

Image 5
Contents Introduction Operating SpecificationsUnpacking And Inspection System AssemblyProcessor Assembly Mounting Inlet and Outlet Connections Piping/Tubing ConnectionsControl system operation Recovery adjustment Cartridge Installation and ActivationTDS Operation Placing ENVI-RO Into ServiceDisinfection PERFORMANCE* section RO Production † Dimensions and operating weights System OnlyStored Water System Cartridges and ElementsPpm Reduction Maintenance section Performance LogInlet Problem Possible Cause Remedy Troubleshooting GuideReplacement Cartridges Replacement PartsEvery 6 months Replace the SR cartridge MaintenanceTop View General Installation Arrangement Page 800.942.1153

ENVI-RO specifications

The Everpure ENVI-RO is a revolutionary reverse osmosis water filtration system designed to deliver high-quality drinking water while ensuring exceptional taste, safety, and convenience. Ideal for residential settings, this advanced system employs cutting-edge technology to remove impurities, contaminants, and unwanted minerals, providing users with clean and refreshing water.

One of the standout features of the ENVI-RO is its multi-stage filtration process, which includes a pre-filter, reverse osmosis membrane, and post-filter. The pre-filter effectively captures larger particles and sediments, prolonging the life of the subsequent filters. The heart of the system, the reverse osmosis membrane, boasts a high rejection rate for a wide range of contaminants, such as chlorine, lead, fluoride, and nitrates, resulting in water that is not only pure but also tastes fantastic.

The post-filter further enhances the quality of the water by removing any remaining odors and tastes, ensuring that each drop is crisp and clean. The ENVI-RO system also features an integrated water storage tank that provides ample supply, delivering filtered water on demand. The tank is designed to minimize space, making it an ideal choice for kitchens with limited under-sink areas.

Another notable characteristic of the Everpure ENVI-RO is its ease of installation and maintenance. Designed with user-friendliness in mind, the system can be installed without the need for professional assistance, allowing homeowners to enjoy high-quality water quickly and efficiently. The filters are easily replaceable, and the system includes a convenient indicator light that alerts users when it’s time for a filter change, ensuring optimal performance at all times.

Durability and reliability are also key components of the ENVI-RO design. The system features high-quality materials that ensure long-lasting performance, coupled with a design that minimizes wastewater during the filtration process, making it an environmentally friendly choice.

Whether for cooking, drinking, or preparing beverages, the Everpure ENVI-RO provides a superior solution for families seeking the best in water quality. With its innovative technologies and user-centric features, the ENVI-RO system stands as a testament to Everpure's commitment to delivering clean, delicious water that enhances everyday living.