ABOUT THE FILTER CARTRIDGE
Performance Data Sheet
GXWH20F system using FXUSC (Rev. 2) filter has been tested according to NSF/ANSI 42 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system
was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42. While testing was performed under standard laboratory conditions, actual performance may vary.
| INFLUENT CHALLENGE | REDUCTION |
|
| |||
SUBSTANCE | CONCENTRATION |
| REQUIREMENT | Rated Service Flow: 8 gpm | |||
Particulate, Class V particles 30 to < 50 | At least 1,000 particles/mL | > + 85% |
| ||||
| |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
Replacement Filter Cartridges |
|
|
|
|
|
| Rated Service Flow: 4 gpm |
|
|
|
|
|
|
| |
|
| GE MODEL | FUNCTION | LIFE | CONSTRUCTION | ||
|
|
| |||||
Several variables determine how long the cartridge will |
|
|
|
|
|
| |
| FXUSC (Rev. 2) | Sediment* | 3 month/16,000 gallons* | Polypropylene Fiber | |||
last in your Household Water Filtration Housing. These |
| ||||||
| FXWPC |
| Sediment* | 3 month/16,000 gallons* | Pleated | ||
include: |
|
|
| ||||
■ levels of sediment or other undesirable substances in |
|
|
|
|
|
| |
your water. |
|
| FXWSC |
| Sediment* | 3 month/16,000 gallons* | String Wound |
■ the amount of water you use. |
|
|
|
| 10 Micron |
|
|
■ the filter location (filtering all or part of your |
| FXWTC (Rev. 2) | Sediment* | 3 month/15,000 gallons* | Carbon Paper | ||
household water). |
|
|
|
| 5 Micron |
|
|
|
|
|
|
| Chlorine |
|
|
|
|
| *Above data are based on manufacturer’s internal testing. |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Filter Cartridge Replacement |
|
|
|
|
|
|
|
You should change your filter when the water flow is noticeably reduced or at least every 3 months.
1 | Turn off water to filter. For model GXWH04F, water | 6 | Reinstall the filter canister to the unit. Tighten filter |
| ||
must be shut off from an upstream valve. For model | canister to seal. Use canister wrench if necessary. |
| ||||
| GXWH20F, rotate control handle to the BYPASS or | 7 | Slowly rotate control handle to the FILTER position |
| ||
| OFF position. (See Control Handle.) | Turn canister wrench | ||||
| (model GXWH20F) or slowly turn on the upstream | |||||
2 | Press the red pressure release button to release |
|
| clockwise to remove | ||
|
|
| ||||
pressure. |
| Press the red pressure release button to remove | Filter canister | |||
3 | Unscrew the filter canister and discard used filter. | 8 trapped air. |
|
| ||
|
|
| ||||
Wash the filter canister with mild soap and water. Do | 9 | Open any downstream faucet and allow filter system |
| |||
| not use harsh cleaners or hot water. |
| ||||
4 | to flush for 5 minutes. |
|
|
| ||
Inspect the filter canister | GXWH04F | Red pressure | GXWH20F | |||
lightly lubricated with clean food grade silicone |
| Timer |
| Timer | ||
| grease (silicone grease is available through GE Parts |
| release button |
|
| |
|
|
|
|
|
| |
| and Service: 1.800.626.2002, part number |
|
|
| Head |
|
| WS60S10005). Be sure the |
|
|
|
| |
|
|
| Head Red pressure | Control | ||
| groove. It is recommended that you replace the |
| Filter | |||
|
| release button | handle | |||
5 |
| cartridge | Filter | |||
Place a new filter cartridge into the canister, making |
|
|
| |||
|
| cartridge |
| |||
sure it is centered and completely seated on the |
|
|
|
| ||
|
|
|
|
| ||
| bottom seal. |
|
| Filter canister |
| Filter canister |
|
|
|
|
|
Control Handle (GXWH20F Model Only)
OFF | FILTER |
■ Shuts off water. | ■ For filtered water. Directs water |
| flow through filter. |
| 2 |
BYPASS
■Permits flow of water to the house without flowing through the filter. Use this position for filter changes or if filtered water is not desired.